ASTM C1686-2009(2017) Standard Practice for Installation and Testing of Reinforced Autoclaved Aerated Concrete (AAC) Units《增强热压加气混凝土(AAC)结构安装和试验的标准实施规程》.pdf
《ASTM C1686-2009(2017) Standard Practice for Installation and Testing of Reinforced Autoclaved Aerated Concrete (AAC) Units《增强热压加气混凝土(AAC)结构安装和试验的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1686-2009(2017) Standard Practice for Installation and Testing of Reinforced Autoclaved Aerated Concrete (AAC) Units《增强热压加气混凝土(AAC)结构安装和试验的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1686 09 (Reapproved 2017)Standard Practice forInstallation and Testing of Reinforced Autoclaved AeratedConcrete (AAC) Units1This standard is issued under the fixed designation C1686; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the installation and testing of solid,reinforced units made from autocl
3、aved aerated concrete(AAC), a cementitious product addressed by SpecificationC1693. The units are large-sized, factory-reinforced, solidrectangular prisms, laid using thin-bed mortar.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathemat
4、icalconversions to SI units that are provided for information onlyand are not considered standard.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not conside
5、red standard.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization Technic
6、alBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C1693 Specification for Autoclaved Aerated Concrete(AAC)3. Classification3.1 Reinforced AAC units installed in accordance with thispractice shall be classified according to their strength class.4. Materials and Manufactur
7、e4.1 Reinforced AAC units installed in accordance with thispractice shall be composed entirely of AAC material conform-ing to Specification C1693. The units themselves shall conformto Specification C1693.5. Significance and Use5.1 This practice is intended to regulate the installation ofreinforced A
8、AC units and to provide test methods for deter-mining their transverse load-displacement characteristics andload-carrying capacities.6. Shipping and Handling of Reinforced AAC ReinforcedElement6.1 Reinforced AAC elements shall be protected fromdamage during shipping by placement on pallets or others
9、upports, banding of the elements, placement of materialbetween the elements, or any other method deemed appropriateby the AAC manufacturer. Reinforced AAC elements shouldbe handled using lifting devices or clamps recommended bythe AAC manufacturer.7. Repair of Reinforced Elements7.1 Damage from hand
10、ling or shipping of reinforced AACelements shall be repaired using special AAC repair mortars. Ifthe damage is severe, theAAC manufacturer shall be consultedas to the structural integrity of the element. Damage that resultsin exposure of the reinforced element shall be repaired onlyafter the exposed
11、 steel is coated with a corrosion-resistantcoating as recommended by the AAC manufacturer.8. Field Cutting of Reinforced Elements8.1 Do not field-cut reinforced elements unless approved bythe project engineer and performed in accordance with theAAC manufacturers recommendations.9. Rejection9.1 If, u
12、pon delivery, an individual element fails to conformto this practice, the manufacturer shall be permitted to repairthe element to satisfy the specification, or to replace theelement.10. Expense of Tests10.1 Except as specified in Section 9, and unless otherwiseagreed, the expense of inspection and t
13、esting shall be theresponsibility of the purchaser.1This practice is under the jurisdiction of ASTM Committee C27 on PrecastConcrete Products and is the direct responsibility of Subcommittee C27.60 onPrecast Autoclaved Aerated Concrete.Current edition approved June 1, 2017. Published July 2017. Orig
14、inally approvedin 2009. Last previous edition approved in 2009 as C21209. DOI: 10.1520/C1686-09R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Doc
15、ument Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on
16、Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.111. Installation of Reinforced AAC Units11.1 Installed units covered by this practice shall beprotected against direct exposure to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC168620092017STANDARDPRACTICEFORINSTALLATIONANDTESTINGOFREINFORCEDAUTOCLAVEDAERATEDCONCRETEAACUNITS

链接地址:http://www.mydoc123.com/p-465520.html