ASTM C159-2006(2016) Standard Specification for Vitrified Clay Filter Blocks《釉面陶瓷过滤块的标准规格》.pdf
《ASTM C159-2006(2016) Standard Specification for Vitrified Clay Filter Blocks《釉面陶瓷过滤块的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C159-2006(2016) Standard Specification for Vitrified Clay Filter Blocks《釉面陶瓷过滤块的标准规格》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C159 06 (Reapproved 2016)Standard Specification forVitrified Clay Filter Blocks1This standard is issued under the fixed designation C159; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A num
2、ber in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification establishes the criteria for acceptance,prior to installation, of vitrified clay filter block used intrickling filters
3、for the treatment of sewage and industrialwastes.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 The following precautionary cave
4、at pertains only to thetest method portions shown in Annex A1 Annex A3. Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the appl
5、icability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2C150/C150M Specification for Portland CementC896 Terminology Relating to Clay ProductsE4 Practices for Force Verification of Testing Machines3. Terminology3.1 The definitions for clay, fire clay, shale, and
6、surface clayare as defined in Terminology C896.3.2 Definitions of Terms Specific to This Standard:3.2.1 compressive strengththe pressure, measured in psi(kPa) which causes failure of vitrified clay filter block, with theload being applied to the block in the direction of use.3.2.2 filter blockrectan
7、gular, vitrified clay units with inte-rior drainage channels, having apertures that connect to thedrainage channels through the upper surface. The apertures arearranged to form drainage and aeration grilles that pass air into,and liquids from, overlying filtering media. The drainagechannels of the f
8、ilter block provide for the conveyance of thefiltered liquid away from the filter bed.3.2.2.1 Type I-S and Type I-H filter blockone-piece unitssuitable for constructing a single-course trickling filter floor.3.2.3 lotunless otherwise specified, a lot shall consist ofall filter block of each type of
9、the contract or purchase order.3.2.4 wallsExterior vertical sides of vitrified clay filterblock.3.2.5 websinterior supports separating channels of vitri-fied clay filter block.4. Classification4.1 Filter block are manufactured in the following types:4.1.1 Type I-S, standard rate and4.1.2 Type I-H, h
10、igh rate.4.2 The purchaser shall specify the type of filter block to befurnished.5. Ordering Information5.1 Orders for filter block under this specification shallinclude the following information:5.1.1 Quantity,5.1.2 Type of filter block,5.1.3 ASTM designation and date of issue,5.1.4 Required tests
11、or certification, and5.1.5 Inspection location; factory or point of delivery.6. Materials and Manufacture6.1 Filter block shall be formed from fire clay, shale, surfaceclay, or a combination of these materials.6.2 Formed filter block shall be fired to a suitable tempera-ture to yield a product that
12、is strong, durable, and serviceableand conforms to this specification.7. Chemical Requirements7.1 Acid ResistanceAcid-soluble matter in filter blockshall not exceed 0.25 % by weight when tested as specified inthis specification in any of the following acids: sulfuric(H2SO4), hydrochloric (HCl), nitr
13、ic (HNO3), or acetic(CH3COOH). The test shall be performed only when specified.1This specification is under the jurisdiction of ASTM Committee C04 onVitrified Clay Pipe and is the direct responsibility of Subcomittee C04.20 onMethods of Test and SpecificationsCurrent edition approved Nov. 1, 2016. P
14、ublished November 2016. Originallyapproved in 1941. Last previous edition approved in 2011 as C159 - 06(2011). DOI:10.1520/C0159-06R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume inf
15、ormation, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17.2 The purchaser shall designate the acid or acids to beused in this test.8. Physical Properties8.1 Compressive
16、 StrengthCompressive strength tests shallbe performed on full- or half-size block. The average compres-sive strength of filter block units shall be at least 450 psi (3.1mPa), and no individual unit shall have a compressive strengthless than 400 psi (2.8 mPa). The compressive strength shall becalcula
17、ted on the gross area of the block.8.2 AbsorptionThe average absorption of five filter block,determined by 1-h submersion in boiling water, shall notexceed 6 % by weight.9. Dimensions and Permissible Variations9.1 ApertureThe smallest dimension of an aperture inType I-S and I-H filter block shall no
18、t exceed 112 in. (38 mm),and the total aperture area shall be at least 20 % of the top area.9.2 Drainage Channels:9.2.1 The drainage channel cross-sectional area shall bedefined as the channel area lying below the lowest level of theaperture. Minimum cross-sectional area of drainage channelsin filte
19、r block shall be as shown in the following table:Drainage Channel Cross-Sectional AreaType Area, min, in.2/ft (cm2/m) of widthI-SI-H20 (425)40 (850)9.2.2 Drainage channels of filter block shall be curved ornarrowed at the bottom to maintain velocity in the channels atlow flow.9.2.3 The minimum depth
20、 of drainage channels in filterblock shall be 212 in. (64 mm), measured from the lowest levelof the aperture.9.2.4 There shall be at least two parallel drainage channelsper foot (0.3 m) of width of Type I-S and I-H filter block.9.3 Exterior Walls and Interior WebsThickness of exteriorwalls in Type I
21、-S and I-H filter block shall be at least916 in. (14mm) and interior webs separating drainage channels shall be atleast12 in. (13 mm).9.4 Permissible Variations in Dimensions:9.4.1 Exterior dimensions of filter block shall be the dimen-sions stated by the manufacturer, 614 in./ft (21 mm/m).9.4.2 The
22、 lower bearing surface of filter block shall not varyfrom a plane by more than316 in. ft (16 mm/m) of the greatestdimension of the block.10. Workmanship, Finish, and Appearance10.1 Filter block shall be substantially free of laminations.10.2 Blisters shall not exceed 2 in. (51 mm) in diameter, andbl
23、isters or pimples shall not project more than18 in. (3 mm)above the surface.10.3 Chips shall not exceed 2 in. (51 mm) in length, 1 in.(25 mm) in width, and a depth of316 in. (5 mm).10.4 Open cracks shall be no longer than 112 in. (38 mm)and surface cracks no longer than 3 in. (76 mm). Open crackssha
24、ll not extend through the upper surface from the end of thefilter block to an aperture opening, nor between apertureopenings.11. Sampling11.1 Selection of Test SpecimensFull- or half-size filterblock shall be selected by the purchaser or his representative atpoints he designates when placing the ord
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC15920062016STANDARDSPECIFICATIONFORVITRIFIEDCLAYFILTERBLOCKS 釉面 陶瓷 过滤 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-465235.html