ASTM C1362-2004 Standard Test Method for Flow of Freshly Mixed Hydraulic Cement Concrete《新拌水凝水泥混凝土流动性的标准试验方法》.pdf
《ASTM C1362-2004 Standard Test Method for Flow of Freshly Mixed Hydraulic Cement Concrete《新拌水凝水泥混凝土流动性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1362-2004 Standard Test Method for Flow of Freshly Mixed Hydraulic Cement Concrete《新拌水凝水泥混凝土流动性的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1362 04Standard Test Method forFlow of Freshly Mixed Hydraulic-Cement Concrete1This standard is issued under the fixed designation C 1362; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers determination of the flow of asample of freshly mixed concrete, either in the field or in thelaboratory.1.2 T
3、his test method is applicable to concrete having coarseaggregate up to 37.5 mm in size. If the coarse aggregate islarger than 37.5 mm in size, the test method is applicable whenthe fraction of concrete larger than 37.5 mm is removed inaccordance with Practice C 172.1.3 The values stated in SI units
4、are the standard.1.4 The text of this standard references notes and footnotesthat provide explanatory information. These notes and foot-notes (excluding those in tables and figures) shall not beconsidered as requirements of this standard.1.5 This standard does not purport to address all of thesafety
5、 concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. (WarningFreshhydraulic cementitious mixtures are caustic and may causechemic
6、al burns to skin and tissue upon prolonged exposure.2)2. Referenced Documents2.1 ASTM Standards:3C 172 Practice for Sampling Freshly Mixed ConcreteC 670 Practice for Preparing Precision and Bias Statementsfor Test Methods for Construction Materials3. Summary of Test Method3.1 A flow apparatus compri
7、sing an outer partially perfo-rated hollow tube and an inner calibrated floating rod isinserted into a sample of freshly mixed concrete to a presetlevel and held in place by a collar floater. A portion of theconcrete is allowed to flow into the hollow tube through itsperforations for a period of 40
8、s. The inner floating rod is thenlowered onto the concrete surface that has penetrated thehollow tube. The height of the concrete in the hollow tube isread from the scale on the upper portion of the floating rodprotruding from the top of the hollow tube. With increasingfluidity of the concrete a hig
9、her flow reading is obtained on ascale from zero to one hundred divisions.4. Significance and Use4.1 This test method permits a rapid assessment of the flowand consistency of freshly mixed concrete (see Note 1).4.2 This test method also provides information on thechange in flow and consistency with
10、time of concrete contain-ing superplasticizer admixtures.4.3 This test method can be used to measure the uniformitycharacteristics of flow and consistency of freshly mixedconcrete and its change with time.NOTE 1This test method may not be appropriate for use in evaluatinggap-graded aggregate concret
11、e.5. Apparatus5.1 Details of the apparatus are shown in Fig. 1. Theapparatus consists of (1) measuring rod, (2) scale datum, (3)hollow tube with round holes and longitudinal slots, (4)holding pin, (5) collar floater, and (6) tube point.5.2 Measuring rod is a hollow tube, 13 mm in outsidediameter, 33
12、6 mm long with a wall thickness of 1.5 mm and itis capped at both ends with a cap 15 mm in outside diameter.A scale datum is 45 mm in outside diameter and 25 mm wideand fabricated to fit hollow tube and accommodate measuringrod. Hollow tube has an outside diameter of 33 mm, and it is310 mm long with
13、 a wall thickness of 4 mm and has 16 roundholes, 9.4 mm in diameter, and 4 longitudinal slots, 9.4 mmwide by 50 mm long, which are distributed around thecircumference of the tube as shown in Fig. 1. A pin which is arivet, 3.2 mm in diameter, protrudes 3.2 mm inside tube. Collarfloater, made of a pla
14、te 5 mm thick, has an outside diameter of90 mm and inside diameter of 33 mm, is connected to hollowtube. Tube point is machined from a rod stock and fashionedinto a conical shape. It is secured to the bottom end of hollowtube, and it is used to facilitate the insertion of the assemblyinto the fresh
15、concrete. All individual dimensions shall have a1This test method is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct responsibility of SubcommitteeC09.60 on Testing Fresh Concrete.Current edition approved June 1, 2004. Published June 2004. Originally
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC13622004STANDARDTESTMETHODFORFLOWOFFRESHLYMIXEDHYDRAULICCEMENTCONCRETE 新拌水凝 水泥 混凝土 流动性 标准 试验 方法

链接地址:http://www.mydoc123.com/p-464358.html