ASTM C1289-2012e1 Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board《贴面硬质泡沫聚异氰尿酸酯隔热板的标准规格》.pdf
《ASTM C1289-2012e1 Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board《贴面硬质泡沫聚异氰尿酸酯隔热板的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1289-2012e1 Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board《贴面硬质泡沫聚异氰尿酸酯隔热板的标准规格》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1289 121Standard Specification forFaced Rigid Cellular Polyisocyanurate Thermal InsulationBoard1This standard is issued under the fixed designation C1289; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1NOTE4.1.2.4 was editorially corrected in December
3、2012.1. Scope1.1 This specification covers the general requirements forfaced thermal insulation boards composed of rigid cellularpolyisocyanurate surfaced with other materials. The insulationboards are intended for use at temperatures between 40 and200F (40 and 93C). This specification does not cove
4、rcryogenic applications. Consult the manufacturer for specificrecommendations and properties in cryogenic conditions. Forspecific applications, the actual temperature limits shall beagreed upon by the manufacturer and the purchaser.1.2 This standard is intended to apply to rigid cellularpolyurethane
5、-modified polyisocyanurate thermal insulationboard products that are commercially acceptable as non-structural panels useful in building construction. The termpolyisocyanurate encompasses the term polyurethane. Forengineering and design purposes, users should follow specificproduct information provi
6、ded by board manufacturers regard-ing physical properties, system design considerations andinstallation recommendations.NOTE 1See Appendix X1 for guidance on determining wind pressureresistance of panels when required for wall sheathing applications.1.3 The use of thermal insulation materials covere
7、d by thisspecification is typically regulated by building codes, or otheragencies that address fire performance. Where required, the fireperformance of the material shall be addressed through stan-dard fire test methods established by the appropriate governingdocuments.1.4 The values stated in inch-
8、pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.NOTE 2For conversion to metric units other than those contained inthis standard, refer to IEEE/ASTM SI 10.1.5 This
9、standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2
10、.1 The following documents, of the issue in effect on thedate of material purchase, form a part of this specification tothe extent specified herein:2.2 ASTM Standards:2C168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Pr
11、operties by Means ofthe Guarded-Hot-Plate ApparatusC203 Test Methods for Breaking Load and Flexural Proper-ties of Block-Type Thermal InsulationC208 Specification for Cellulosic Fiber Insulating BoardC209 Test Methods for Cellulosic Fiber Insulating BoardC303 Test Method for Dimensions and Density o
12、f Pre-formed Block and BoardType Thermal InsulationC390 Practice for Sampling and Acceptance of ThermalInsulation LotsC518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC550 Test Method for Measuring Trueness and Squarenessof Rigid Block and Boa
13、rd Thermal InsulationC728 Specification for Perlite Thermal Insulation BoardC1045 Practice for Calculating Thermal Transmission Prop-erties Under Steady-State ConditionsC1058 Practice for Selecting Temperatures for Evaluatingand Reporting Thermal Properties of Thermal Insulation1This specification i
14、s under the jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.22 onOrganic and Nonhomogeneous Inorganic Thermal Insulations.Current edition approved May 1, 2012. Published July 2012. Originally approvedin 1995. Last previous edition approved
15、 in 2011 as C1289 11a. DOI: 10.1520/C1289-12E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright AST
16、M International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1C1114 Test Method for Steady-State Thermal TransmissionProperties by Means of the Thin-Heater ApparatusC1177/C1177M Specification for Glass Mat Gypsum Sub-strate for Use as SheathingC1303 Test Method
17、 for Predicting Long-Term Thermal Re-sistance of Closed-Cell Foam InsulationC1363 Test Method for Thermal Performance of BuildingMaterials and Envelope Assemblies by Means of a HotBox ApparatusD1621 Test Method for Compressive Properties of RigidCellular PlasticsD2126 Test Method for Response of Rig
18、id Cellular Plasticsto Thermal and Humid AgingE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE96/E96M Test Methods for Water Vapor Transmission ofMaterialsIEEE/ASTM SI 10 Standard for Use of the InternationalSystem of Units (SI): (The Modernized Metric System)2.3 ANSI Standa
19、rd:Voluntary Product Standard PS 204 Performance Standardfor Wood Based Structural Use Panels Performance Stan-dard for Wood Based structural Use Panels32.4 CAN/ULC Standard:4CAN/ULC-S770-09 Standard Test Method for Determina-tion of Long-Term Thermal Resistance of Closed-CellThermal Insulating Foam
20、s3. Terminology3.1 For complete descriptions of terms used in thisspecification, refer to Terminology C168.3.2 The term polyisocyanurate encompasses the term poly-urethane (see 1.2).4. Classification4.1 The faced thermal insulation boards composed of rigidcellular polyisocyanurate covered by this sp
21、ecification areclassified as follows:4.1.1 Type IFaced with aluminum foil on both majorsurfaces of the core foam.4.1.1.1 Class 1Non-reinforced core foam.4.1.1.2 Class 2Glass fiber reinforced core foam.4.1.2 Type II:4.1.2.1 Class 1Faced with glass fiber reinforced cellulosicfelt or uncoated or coated
22、 polymer-bonded glass fiber matfacers on both major surfaces of the core foam.(1) Grade 116 psi (110 kPa), min, compressive strength.(2) Grade 220 psi (138 kPa), min, compressive strength.(3) Grade 325 psi (172 kPa), min, compressive strength.4.1.2.2 Class 2Faced with coated polymer-bonded glassfibe
23、r mat facers on both major surfaces of the core foam.4.1.2.3 Class 3Faced with uncoated polymer-bondedglass fiber mat facers on both major surfaces of the core foam.4.1.2.4 Class 4Faced with coated or uncoated polymer-bonded glass fiber mat facers on both major surfaces of thecore foam. This product
24、 is used at a maximum thickness of12in. (12.7mm).(1) Grade 180 psi (551 kPa), min, compressive strength(2) Grade 2110 psi (758 kPa), min, compressive strength(3) Grade 3140 psi (965 kPa), min, compressive strength4.1.3 Type IIIFaced with a perlite insulation board on onemajor surface of the core foa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC12892012E1STANDARDSPECIFICATIONFORFACEDRIGIDCELLULARPOLYISOCYANURATETHERMALINSULATIONBOARD 贴面 硬质

链接地址:http://www.mydoc123.com/p-464095.html