ASTM C1136-2017 Standard Specification for Flexible Low Permeance Vapor Retarders for Thermal Insulation《隔热用柔性低渗透蒸汽阻化剂的标准规格》.pdf
《ASTM C1136-2017 Standard Specification for Flexible Low Permeance Vapor Retarders for Thermal Insulation《隔热用柔性低渗透蒸汽阻化剂的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1136-2017 Standard Specification for Flexible Low Permeance Vapor Retarders for Thermal Insulation《隔热用柔性低渗透蒸汽阻化剂的标准规格》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1136 16C1136 17Standard Specification forFlexible, Low Permeance Vapor Retarders for ThermalInsulation1This standard is issued under the fixed designation C1136; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification covers v
3、apor retarders for thermal insulation, specifically, flexible materials with permeance of 0.10 permor lower and surface burning characteristics of 25 flame spread/50 smoke or lower. These materials are intended for use at surfacetemperatures of 20 to 150F (29 to 66C). It does not cover mastics or ba
4、rrier coatings applied in liquid form, nor materialsintended for use as weather barriers.1.2 This is a material specification and does not imply that an installed system using these materials will provide the physicalproperties specified in Section 6.1.3 This specification provides physical requirem
5、ents for vapor retarders. Practice C755 provides assistance in solving problemsrelated to moisture vapor transmission through thermal insulation materials.1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units
6、 that are provided for information only and are not considered standard.1.5 The following precautionary caveat pertains to the test methods portion only, Section 10, of this specification:This standarddoes not purport to address all of the safety concerns, if any, associated with its use. It is the
7、responsibility of the user of thisstandard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardizationestablished
8、in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C168 Terminology Relating to Thermal InsulationC755 Practice for Selec
9、tion of Water Vapor Retarders for Thermal InsulationD774/D774M Test Method for Bursting Strength of Paper (Withdrawn 2010)3C1258 Test Method for Elevated Temperature and Humidity Resistance of Vapor Retarders for InsulationC1263 Test Method for Thermal Integrity of Flexible Water Vapor RetardersC133
10、8 Test Method for Determining Fungi Resistance of Insulation Materials and FacingsD828 Test Method for Tensile Properties of Paper and Paperboard Using Constant-Rate-of-Elongation ApparatusD882 Test Method for Tensile Properties of Thin Plastic SheetingD1204 Test Method for Linear Dimensional Change
11、s of Nonrigid Thermoplastic Sheeting or Film at Elevated TemperatureD3285 Test Method for Water Absorptiveness of Nonbibulous Paper and Paperboard (Cobb Test) (Withdrawn 2010)3E84 Test Method for Surface Burning Characteristics of Building MaterialsE96/E96M Test Methods for Water Vapor Transmission
12、of Materials1 This specification is under the jurisdiction ofASTM Committee C16 on Thermal Insulation and is the direct responsibility of Subcommittee C16.33 on Insulation Finishesand Moisture.Current edition approved Nov. 1, 2016May 15, 2017. Published November 2016May 2017. Originally approved in
13、1990. Last previous edition approved in 20122016 asC1136 12.C1136 16. DOI: 10.1520/C1136-16.10.1520/C1136-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the stan
14、dards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous versio
15、n. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International
16、, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.2 TAPPI Standards:T461 Flame Resistance of Treated Paper and Paperboard3. Terminology3.1 DefinitionsDefinitions in Terminology C168 apply to terms used in this specification.4. Classification4.1 Classification of
17、 vapor retarders, with the exception of Type IX, is based on physical properties.4.1.1 Type IX, in addition to physical property requirements, has specific structural requirements.4.2 Physical property requirements are listed in Table 1.5. Materials and Manufacture5.1 Vapor retarders, with the excep
18、tion of Type IX, are constructed of various films, metallic foils, fabrics, papers andreinforcements, alone or in combination as a lamination.5.2 Metallic foils, the most commonly used being aluminum of a minimum gauge, are the only materials expected to providethe impermeable component in a vapor r
19、etarder required for Type IX.5.2.1 Type IX vapor retarders must contain at a minimum the following components in the structure:5.2.2 One layer of metallic foil with a minimum thickness of 0.00095 in. (24.1) or5.2.3 Multiple layers of metallic foil with a cumulative minimum thickness of 0.0012 in. (3
20、0.5)5.2.4 A fully laminated, continuous protective substrate on at least one side of the foil layers5.3 Types VII-X vapor retarders contain water resistant outer surfaces.6. Physical Properties6.1 Maximum permeance for a specific type vapor retarder shall be as shown in Table 1 when tested in accord
21、ance with 10.1.Values for permeance requirements are rounded to two decimals.6.2 All vapor retarders shall demonstrate a flame spread of 25 or less and smoke developed of 50 or less when testing the finishside (the side opposite that contacting the insulation) in accordance with 10.2.6.3 Minimum ten
22、sile strength for a specific type vapor retarder shall be as shown in Table 1 when tested in accordance with10.3.6.4 Maximum dimensional change for a specific type vapor retarder shall be as shown in Table 1, when tested in accordancewith 10.4.6.5 All type vapor retarders shall not sustain growth of
23、 fungi when tested in accordance with 10.5.6.6 All type vapor retarders shall not crack or delaminate at temperatures from 20 to 150F (29 to 66C) when tested inaccordance with 10.6.6.7 Minimum burst strength for a specific type vapor retarder shall be as shown in Table 1 when tested in accordance wi
24、th 10.7.6.8 Vapor retarders containing paper or paper products shall not demonstrate an increase in char length of more than 20 % whentested in accordance with 10.8.6.9 All type vapor retarders shall not corrode or delaminate, nor demonstrate, after exposure, a permeance greater than themaximum allo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC11362017STANDARDSPECIFICATIONFORFLEXIBLELOWPERMEANCEVAPORRETARDERSFORTHERMALINSULATION 隔热 柔性 渗透

链接地址:http://www.mydoc123.com/p-463502.html