ASTM B231 B231M-2012 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors《同心绞捻铝1350导线的标准规格》.pdf
《ASTM B231 B231M-2012 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors《同心绞捻铝1350导线的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM B231 B231M-2012 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors《同心绞捻铝1350导线的标准规格》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B231/B231M 11 B231/B231M 12Standard Specification forConcentric-Lay-Stranded Aluminum 1350 Conductors1This standard is issued under the fixed designation B231/B231M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers alu
3、minum 1350-H19 (extra hard), 1350-H16 or -H26 (34 hard), 1350-H14 or -H24 (12 hard), and1350-H142 or -H242 (12 hard), bare concentric-lay-stranded conductors constructed with a straight round central wire surroundedby one or more layers of helically layed wires. The conductors are for general use fo
4、r electrical purposes (Explanatory Note 1 andNote 2).1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values
5、 from thetwo systems may result in non-conformance with the standard.1.2.1 For density, resistivity and temperature, the values stated in SI units are to be regarded as standard.NOTE 1Prior to 1975, aluminum 1350 was designated as EC aluminum.NOTE 2The aluminum and temper designations conform to ANS
6、I Standard H35.1/H35.1M. Aluminum 1350 corresponds to Unified NumberingSystem A91350 in accordance with Practice E527.NOTE 3Sealed conductors that are intended to prevent longitudinal water propagation and are further covered/insulated are also permitted within theguidelines of this specification.2.
7、 Referenced Documents2.1 The following documents of the issue in effect on date of material purchase form a part of this specification to the extentreferenced herein:2.2 ASTM Standards:2B193 Test Method for Resistivity of Electrical Conductor MaterialsB230/B230M Specification for Aluminum 1350H19 Wi
8、re for Electrical PurposesB263 Test Method for Determination of Cross-Sectional Area of Stranded ConductorsB354 Terminology Relating to Uninsulated Metallic Electrical ConductorsB609/B609M Specification for Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical PurposesB682 Spec
9、ification for Metric Sizes of Electrical ConductorsE29 Practice for Using Significant Digits in Test Data to Determine Conformance with SpecificationsE527 Practice for Numbering Metals and Alloys in the Unified Numbering System (UNS)2.3 ANSI Documents:3ANSI H35.1 American National Standard Alloy and
10、 Temper Designation System for AluminumANSI H35.1M American National Standard Alloy and Temper Designation Systems for Aluminum Metric2.4 NIST Document:4NBS Handbook 100Copper Wire Tables2.5 Aluminum Association Document:5Publication 50, Code Words for Overhead Aluminum Electrical Conductors1 This s
11、pecification is under the jurisdiction of ASTM Committee B01 on Electrical Conductors and is the direct responsibility of Subcommittee B01.07 on Conductorsof Light Metals.Current edition approved April 1, 2011June 1, 2012. Published May 2011October 2012. Originally approved in 1948. Last previous ed
12、ition approved in 20042011 asB231/B231M 04.B231/B231M 11. DOI: 10.1520/B0231_B0231M-11.10.1520/B0231_B0231M-12.2 For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the
13、 standards Document Summary page on the ASTM website.3 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036.4 Available from National Technical Information Service (NTIS), U.S. Department of Commerce, 5285 Port Royal Rd., Springfield, VA 22161.5
14、Available from the Aluminum Association, Inc., 900 19th Street, NW, Suite 300, Washington, DC 20006.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technicall
15、y possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C7
16、00, West Conshohocken, PA 19428-2959. United States13. Classification3.1 For the purpose of this specification, conductors are classified as follows (Explanatory Note 1 and Note 2):3.1.1 Class AAFor bare conductors usually used in overhead lines.3.1.2 Class AFor conductors to be covered with weather
17、-resistant materials, and for bare conductors where greater flexibilitythan is afforded by Class AA is required. Conductors intended for further fabrication into tree wire or to be insulated and laidhelically with or around aluminum or ACSR messengers, shall be regarded as Class A conductors with re
18、spect to direction of layonly (see 7.4).3.1.3 Class BFor conductors to be insulated with various materials such as rubber, paper, varnished cloth, and so forth, andfor the conductors indicated under Class A where greater flexibility is required.3.1.4 Classes C and DFor conductors where greater flexi
19、bility is required than is provided by Class B conductors.4. Ordering Information4.1 Orders for material under this specification shall include the following information:4.1.1 Quantity,4.1.2 Conductor size: square millimetres, if cross-sectional area is specified as a requirement (Section 8 and Tabl
20、es 1-4),4.1.2.1 Conductor size, number, and diameter of wires for Class B, C, or D conductors, if cross-sectional area is not specifiedas a requirement (see 8.2),4.1.3 Class (see 3.1),4.1.4 Temper (see 5.1),4.1.5 Details of special-purpose lays, when required (see 7.2 through 7.5),4.1.6 Special tens
21、ion tests if required (see 14.1 and 15.1),4.1.7 Package size and type (see 17.1 and Table 1 or Table 2),4.1.8 Special package marking, if required (Section 19),4.1.9 Heavy wood lagging, if required (see 18.2),4.1.10 Place of inspection (Section 17), and4.1.11 Method of cross-sectional area determina
22、tion if not optional (see 12.1).5. Requirements for Wires5.1 Aluminum wire employed in Classes AA and A conductors shall be 1350-H19, unless otherwise specified. The purchasershall designate the temper of conductors of Classes B, C, and D.5.1.1 For conductor tempers other than 1350-H19, when temper
23、designations are not more specific in the inquiry and purchaseorder, the manufacturer shall have the following options on manufacturing method:5.1.1.1 Strand the conductor from wires drawn to final temper;5.1.1.2 Strand the conductor from wires drawn to H19 temper and annealed to final temper prior
24、to stranding;5.1.1.3 Strand the conductor from 1350-H19 wires and anneal the stranded conductor to final temper.5.2 Before stranding, the aluminum wire used shall meet the requirements of Specifications B230/B230M or B609/B609M,whichever is applicable.5.3 All wires in the conductor shall be of the s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB231B231M2012STANDARDSPECIFICATIONFORCONCENTRICLAYSTRANDEDALUMINUM1350CONDUCTORS 同心 绞捻铝 1350 导线 标准
链接地址:http://www.mydoc123.com/p-460691.html