ASTM B106-1996(2002)e1 Standard Test Methods for Flexivity of Thermostat Metals《恒温金属挠性的标准试验方法》.pdf
《ASTM B106-1996(2002)e1 Standard Test Methods for Flexivity of Thermostat Metals《恒温金属挠性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM B106-1996(2002)e1 Standard Test Methods for Flexivity of Thermostat Metals《恒温金属挠性的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B 106 96 (Reapproved 2002)e1Standard Test Methods forFlexivity of Thermostat Metals1This standard is issued under the fixed designation B 106; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEParagraph 1.3 was corrected editorially in June 2002.1. Scope1.1 These test methods cover the determination of flexivity(a measure of ther
3、mal deflection rate or deflection temperaturecharacteristics) of thermostat metals.1.1.1 Test Method ATested in the form of flat strip 0.012in. (0.30 mm) or over in thickness.1.1.2 Test Method BTested in the form of spiral coils lessthan 0.012 in. in thickness.1.2 The values stated in inch-pound uni
4、ts are to be regardedas the standard. The values given in parentheses are providedfor information purposes only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to become familiarwith all ha
5、zards including those identified in the appropriateMaterial Safety Data Sheet for this product/material as pro-vided by the manufacturer, to establish appropriate safety andhealth practices, and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standar
6、ds:B 389 Test Method for Thermal Deflection Rate of Spiraland Helical Coils of Thermostat Metal23. Terminology3.1 Definitions:3.1.1 thermostat metala composite material in the form ofsheet or strip comprising two or more metallic layers ofdiffering coefficients of thermal expansion, such that the ra
7、diusof curvature of the composite changes with temperaturechange.3.1.2 flexivity (F)the change of curvature of the longitu-dinal center line of the specimen per unit temperature changefor unit thickness, given by the following equation:F 5 t1/R2! 2 1/R1!T22 T1(1)To determine the flexivity between an
8、y two temperatures, T1and T2, it is necessary to measure the curvature 1/ R1and 1/R2at temperature T1and T2, respectively. To find the curvature ateither temperature (Fig. 1 and Fig. 2), measure the distance D.The curvature is given by the following equation:1/R 5 8 D/Q21 4Dt 1 4D2! (2)where:R = rad
9、ius of curvature of the longitudinal center line ofthe specimen, in. (mm),t = thickness of test specimen, in. (mm),Q = distance between support points, in. (mm), andD = for point support (simply supportedbeam), = perpendicular distance between the longitu-dinal center lines of the lower surface of t
10、he specimenmidway between the point supports and the straightline joining the support points, in. (mm).4. Significance and Use4.1 These test methods are used for determining response totemperature change or flexivity of thermostat metal. Theflexivity is calculated from the temperatures, dimensions o
11、fspecimen, and the relative movement of the specimen. Thesimple beam method is the method for certification. Any use ofthe spiral coil method (Method B) is to be mutually agreedupon between the user and supplier.TEST METHOD AFLAT STRIPS5. Apparatus5.1 Specimen Carrier, provided with two conical supp
12、ortsfor locating the specimen. The test length (that is, the distancebetween the point of contact of the specimen with one supportand the point of contact of the specimen with the other support)1These test methods are under the jurisdiction of ASTM Committee B02 onNonferrous Metals and Alloys and is
13、 the direct responsibility of SubcommitteeB02.10 on Thermostat Metal and Electrical Resistance Heating Materials.Current edition approved Jan. 10, 1996. Published April 1996. Originallypublished as B 106 84. Last previous edition B 106 90.2Annual Book of ASTM Standards, Vol 02.04.1Copyright ASTM Int
14、ernational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.shall be known to within 60.005 in. (0.13 mm), and the line ofplane passing through the points of contact shall be horizontal.The specimen carrier and supports shall hold the specimenwithout constraint so
15、 that the curvature, due to its deflection,will follow a vertical plane passing through the line joining thepoints of contact between specimen and supports.5.2 Micrometertraveling microscope, or equivalent de-vice, so connected to the specimen carrier that expansionduring heating of the carrier or c
16、onnecting parts will not causeappreciable displacement of the measuring device with respectto the supports.5.3 BathA stirred liquid bath or uniformly heated enclo-sure in which the specimen carrier, together with adjustableelectric heating source is placed. The specimen needs to bemaintained at the
17、desired temperatures, with a variation intemperature throughout the gage length of the specimen not toexceed 0.5 % of the temperature range used in the test.5.4 Temperature Measuring Apparatus, of such accuracythat the individual temperatures shall be known to within60.5F (0.3C).5.5 Deflection Index
18、Means shall be provided for measur-ing the deflection of the specimen at a point midway betweenthe points of support and along the vertical line intersecting theline joining the points of support. Such means may comprise afused-quartz transmission rod disposed with its axis verticaland terminating i
19、n a point or knife-edge, which shall engagethe specimen midway between the points of contact with thesupports.5.5.1 The transmission rod shall be mounted in such amanner that it is free to move in the direction of its axis. Therod shall bear at its free end an index suitable for microscopicalobserva
20、tion, or else an electrical contact with which a mi-crometer will permit the changes of the deflection of specimento be accurately observed. Alternatively, the deflection of themidpoint of the specimen may be directly observed by opticalmeans whose line of sight is horizontal and passes through thev
21、ertical line through the midpoint of the specimen. A microme-ter screw with extended spindle making direct contact with thespecimen may be used. In this case, electrical means shall beprovided that will indicate contact without significant distur-bance of the specimen. The measurement of the positio
22、n of themidpoint of the test specimen shall be of such accuracy that theindividual positions at the test temperatures shall be known towithin 60.0002 in. (0.005 mm).5.5.2 If a transmission rod is used, it and any attached partsshall be of such weight or so counterweighted that they will notcause a d
23、eflection greater than 1 % of the maximum to beproduced by the action of the thermostat metal alone. Whenfree, the thermostat metal assumed very nearly a circularcurvature. Concentrated loading at the center of the specimenwill cause the curvature to be other than circular and may causesignificant e
24、rrors in the evaluation of flexivity. The location ofthe line passing through the points of contact between speci-men and supports shall be known, with reference to the scale ofthe micrometer, to within 60.002 in. (0.05 mm).5.6 All metallic components of the flexivity apparatusshould be made of very
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB10619962002E1STANDARDTESTMETHODSFORFLEXIVITYOFTHERMOSTATMETALS 恒温 金属 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-460346.html