ASTM A664-2014 Standard Practice for Identification of Standard Electrical Steel Grades in ASTM Specifications《美国材料试验学会规范中鉴定标准电工钢等级的标准操作规程》.pdf
《ASTM A664-2014 Standard Practice for Identification of Standard Electrical Steel Grades in ASTM Specifications《美国材料试验学会规范中鉴定标准电工钢等级的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM A664-2014 Standard Practice for Identification of Standard Electrical Steel Grades in ASTM Specifications《美国材料试验学会规范中鉴定标准电工钢等级的标准操作规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A664 11A664 14Standard Practice forIdentification of Standard Electrical Steel Grades in ASTMSpecifications1This standard is issued under the fixed designation A664; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the procedure for designating (within ASTM specifications) standard grades of flat-rolled
3、 electricalsteels made to specified maximum values of core loss. This practice applies to magnetically soft irons and steel (low-carbon steelsand alloys of iron with silicon, aluminum, and so forth) where a core loss measurement at a stated peak value of alternatinginduction and a stated frequency,
4、such as 15 kG (1.5 T) and 60 Hz, is normally used to grade the material. This practice also applieswhen some other property is specified (or a different induction or frequency, or both) as the limiting characteristic, provided thematerial also meets all the requirements of the ASTM specification.1.2
5、 Individual specifications that are in conformity with this practice are Specifications A677, A683, A726, A876and , andA876A1086.1.3 The values stated in customary (cgs-emu and inch-pound) units are to be regarded as standard. The values given inparentheses are mathematical conversions to SI units w
6、hich are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine th
7、e applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A340 Terminology of Symbols and Definitions Relating to Magnetic TestingA677 Specification for Nonoriented Electrical Steel Fully Processed TypesA683 Specification for Nonoriented Electrical Steel, Semip
8、rocessed TypesA726 Specification for Cold-Rolled Magnetic Lamination Quality Steel, Semiprocessed TypesA876 Specification for Flat-Rolled, Grain-Oriented, Silicon-Iron, Electrical Steel, Fully Processed TypesA976 Classification of Insulating Coatings for Electrical Steels by Composition, Relative In
9、sulating Ability and ApplicationA1086 Specification for Thin-Gauge Nonoriented Electrical Steel Fully Processed Types3. Terminology3.1 The terms and symbols used in this practice are defined in Terminology A340.4. Procedure4.1 General Requirements of the Core-Loss-Type DesignationsThe core-loss-type
10、 designations to be used for orderingpurposes and for identification of the shipped material in ASTM specifications for electrical steels shall be a six-characteridentification (for example, 36F145) comprised of the following basic elements:4.1.1 First Two DigitsThe first two digits of the grade des
11、ignation shall represent the nominal decimal thickness of thematerial in millimetres. For instance, the number 36 represents a thickness of 0.36 mm or 0.014 in. Refer to Appendix X1 for therelationship between Electrical Sheet Gauge Number and thickness.1 This practice is under the jurisdiction of A
12、STM Committee A06 on Magnetic Properties and is the direct responsibility of Subcommittee A06.02 on MaterialSpecifications.Current edition approved Oct. 1, 2011May 1, 2014. Published October 2011May 2014. Originally approved in 1972. Last previous edition approved in 20062011 asA6640611.1 . DOI: 10.
13、1520/A0664-11.10.1520/A0664-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM s
14、tandard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all c
15、ases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.1.2 Code LettersA code letter shall designate the general category of magnet
16、ic material and the standard sampling andtesting practices that apply. The precise conditions of sampling and testing are given in theASTM specification covering each classof material. The code letter to be used and the sampling and testing conditions associated with that letter shall be as in Table
17、 1.4.1.3 Last DigitsThe last three digits of the grade designation shall represent the maximum permissible core loss in watts perpound for the test conditions indicated by the code letter. For instance, the 145 designation on a standardASTM specification usedin conjunction with the Code Letter F rep
18、resents 1.45 W/lb for the maximum value of core loss determined at 15 kG (1.5 T) and60 Hz on an as-sheared Epstein specimen consisting of one half of the strips cut parallel to the rolling direction and the other halfcut perpendicular to the rolled direction.TABLE 1 Code Letters and Sampling and Tes
19、ting ConditionsCode Letter ASTM Specification Class of Material and Core-Loss Testing ConditionsCode Letter ASTM Specification Class of Material and Core-Loss Testing ConditionsD A726 Magnetic lamination steel, semiprocessed, with core-loss value determined at15 kG (1.5 T) and 60 Hz on Epstein speci
20、mensA after a quality development an-neal at 1450F (790C) with a 1-h soak period.D A726 Magnetic lamination steel, semiprocessed, with core-loss value determined at15 kG (1.5 T) and 60 Hz on Epstein specimensA after a quality development an-neal at 1450F (790C) with a 1-h soak period.F A677 Nonorien
21、ted electrical steel, fully processed, with core-loss value determined at15 kG (1.5 T) and 60 Hz on as-sheared Epstein specimens.AF A677 Nonoriented electrical steel, fully processed, with core-loss value determined at15 kG (1.5 T) and 60 Hz on as-sheared Epstein specimens.AS A683 Nonoriented electr
22、ical steel, semiprocessed, with core-loss value determined at15 kG (1.5 T) and 60 Hz on Epstein specimensA after a quality development an-neal at 1550F (845C) with a 1-h soak period, except that the temperature shallbe 1450F (790C) for alloy contents less than 1.3 % silicon plus aluminum.S A683 Nono
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA6642014STANDARDPRACTICEFORIDENTIFICATIONOFSTANDARDELECTRICALSTEELGRADESINASTMSPECIFICATIONS 美国 材料

链接地址:http://www.mydoc123.com/p-459095.html