《ANSI UL 62275 (ND)-2016 National Differences For Cable Management Systems C Cable Ties for Electrical Installations (Second Edition)《电缆管理系统的国家差异.电器设备用电缆接头(第2版)》.pdf》由会员分享,可在线阅读,更多相关《ANSI UL 62275 (ND)-2016 National Differences For Cable Management Systems C Cable Ties for Electrical Installations (Second Edition)《电缆管理系统的国家差异.电器设备用电缆接头(第2版)》.pdf(58页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForCable Management Systems Cable Ties for Electrical InstallationsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNa
2、tional Differences ForCable Management Systems Cable Ties for Electrical Installations Second EditionEdition Date: October 14, 2016This is the second edition of ANSI/UL 62275.This document provides a single listing of the National Differences included in the UL adoption ofthe corresponding IEC stand
3、ard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this standards document as is without warranty of any k
4、ind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or any othe
5、r damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs liability for any damage ever exceed the pricepaid for this standards document, regardless of the
6、 form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or deviation introduced while purcha
7、ser is storing an electronicStandard on the purchasers computer system.Copyright 2016 Underwriters Laboratories Inc.OCTOBER 14, 2016NATIONAL DIFFERENCES FOR2UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single
8、 listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify national difference type, andthese types are additionally noted in this document. The standard may not use all typ
9、es of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of products.D2 - These are deviations based on safety practices. These are deviations for IEC requirements that maybe
10、acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and will not be deleted until a particularcomponent standard is harmonized with the IEC component standard.DE - These are
11、 deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what the national difference entails. Typically one of thefollowing words is used to explain how the text of the national
12、difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table, figure,or annex. Addition is not meant to include adding select words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an enti
13、re numbered clause, subclause, table,figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as the addition,replacement or deletion of certain words or the replacement of an entire clause, subclause, table, figure,or ann
14、ex of the base IEC text.OCTOBER 14, 2016 NATIONAL DIFFERENCES FOR 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences1DV.1 D2 Modify the first paragraph as follows:This Standard specifies requirements for metallic, non-metall
15、ic and composite cable tiesand their associated fixing devices used for the management and support of wiringsystems in electrical installations in accordance with the Canadian Electrical Code (CEC),Part I, CSA C22.1, in Canada, Standard for Electrical Installations, NOM-001-SEDE, inMexico, and the N
16、ational Electrical Code (NEC), NFPA 70, in the United States of America.1DV.2 D2 Modify by deleting the last paragraph in Clause 1 and adding the followingnote:NOTE This standard considers the mechanical interface of a fixing device to a surface when the means forsecuring is provided with the fixing
17、 device (See 9.7.1DV, 9.7.2DV, and 9.7.3DV).2DV D1 Modify by adding the following to Clause 2:2DV.1 In Canada, the following additional references apply:C22.1-15Canadian Electrical Code, Part ICAN/CSA-C22.2 No. 0-10 (R2015)General requirements Canadian Electrical Code, Part IICAN/CSA-C22.2 No. 0.17-
18、00 (R2013)Evaluation of properties of polymeric materials2DV.2 In the United States, the following additional references apply:National Electrical Code (NEC)NFPA 70-2014UL 94Standard for Tests for Flammability of Plastic Materials for Parts in Devices andAppliancesUL 746AStandard for Polymeric Mater
19、ials Short Term PropertiesUL 746BStandard for Polymeric Materials Long Term Property EvaluationsUL 746CStandard for Polymeric Materials - Use in Electrical Equipment EvaluationsOCTOBER 14, 2016NATIONAL DIFFERENCES FOR4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WIT
20、HOUT PERMISSION FROM ULUL 2043Fire Test for Heat and Visible Smoke Release for Discrete Products and their AccessoriesInstalled in Air-Handling Spaces2DV.3 The following additional references apply:ASTM D1002 - 10Standard Test Method for Apparent Shear Strength of Single-Lap-Joint Adhesively BondedM
21、etal Specimens by Tension Loading (Metal-to-Metal)IEC 60695-11-10: 2013Test flames 50 W horizontal and vertical flame test methods2DV.4 In Mexico, the following references apply. Compliance with the requirements in IECand ISO standards shall be according to the relevant Mexican standards provided in
22、 AnnexDVI:NMX-J-417-ANCE-2005Wires and cables Convection laboratories ovens for evaluation of electrical insulation Specifications and test methodsNMX-J-553-ANCE-2002Wires and cables Weather resistance of insulation or jacket of electrical conductors Test methodNMX-J-564/1-3-ANCE-2010Environmental t
23、esting for electrical equipment Part 1-3: Method of testing corrosionendurance Salt mist3.3DV D2 Modify by replacing the definition of 3.3 with the following:metallic component: component which consists of metal only or a metallic cable tie havinga non-metallic or organic coating, that is considered
24、 not essential in achieving loop tensilestrength3.5DV D1 Modify by adding the following to this definition:For a cable tie principally of nonmetallic construction, the metallic element is determinedto be essential in achieving the loop tensile strength.3DV D1 Add the following terms to Clause 3:3DV.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL62275ND2016NATIONALDIFFERENCESFORCABLEMANAGEMENTSYSTEMSCCABLETIESFORELECTRICALINSTALLATIONSSECONDEDITION

链接地址:http://www.mydoc123.com/p-439447.html