1、Subject 296A 12 Laboratory Drive Research Triangle Park, NC 27709 October 18, 2000 TO: Industry Advisory Conference of UL for Residential Type Oil-Burning Appliances, Electrical Council of Underwriters Laboratories Inc., Fire Council of Underwriters Laboratories Inc., Subscribers to ULs Standards Se
2、rvice for Waste Oil-Burning Air-Heating Appliances SUBJECT: Request for Comments on Proposed Requirements for the Second Edition of the Standard for Waste Oil-Burning Air-Heating Appliances, UL 296A; PROPOSED EFFECTIVE DATE SUMMARY OF TOPICS This bulletin proposes the following changes in requiremen
3、ts: Motor terminal housing minimum dimension specifications Revisions to conduit size Minimum amperage rating of leads and terminals Additional wire types available for use Exceptions to circuit separation requirements The grounding symbol as an additional marking option Additional marking requireme
4、nts for Class 2 and Class 3 circuits Editorial revision COMMENTS DUE: November 29,2000 Attached as Appendix A for your review and comment are proposed requirements for UL 296A. Questions regarding interpretation of requirements should be directed to the responsible UL Staff. Please see Appendix B of
5、 this bulletin regarding designated responsibility for the subject product category. Please note that proposed requirements are of a tentative and early nature and are for review and comment only. Current requirements are to be used to judge a product until these requirements are published in final
6、form. SUBJECT 296A -2- OCTOBER 18,2000 PRODUCTS AND INDUSTRIES AFFECTED BY THE PROPOSAL UL requests your assistance in identifying other products or industries that might be affected by the requirements contained in this bulletin. UL suggests that all suppliers or customers for these products and in
7、dustries be made aware of these requirements prior to their proposed effective date. Also, please forward your suggestions to UL so that these products and industries may be identified in future bulletins. PROPOSED EFFECTIVE DATES The proposed requirements specified in the following table will neces
8、sitate a review of currently Listed products. Therefore, UL proposes that the new requirements become effective 18 months after publication. This is intended to provide manufacturers with sufficient time to acknowledge the modification of products and to implement the necessary changes in production
9、. Please note that this also includes the time that will be needed by UL to conduct a review of the modified product. Item Number I Topic I Reference Number I Proposed Effective Date 1 I Motor Terminal Housing 16.1.4 and 2. Your comments concerning the proposed effective dates, should the proposals
10、be adopted. Comments should be made in writing and may be sent by email, fax, or mail to the attention of Tim Lupo at ULs Research Triangle Park office, 12 Laboratory Drive, Research Triangle Park, NC 27709-3995. Please reference all correspondence to Subject 296A. All comments should be sent by Nov
11、ember 29, 2000. Unless specifically requested to do so, UL will not acknowledge comments indicating concurrence with these proposals. SUBJECT 296A OCTOBER 18,2000 UNDERWRITERS LABORATORIES INC. TIM LUPO Associate Project Engineer Standards Department RESEARCH TRIANGLE PARK OFFICE Fax: (919) 547-6480
12、 Email: timothy.e.lupoQ (919) 549-1491 SR:JAH REVIEWED BY: T.K. THOMPSON Staff Engineering Associate Conformity Assessment Services 301 5BRTP RESEARCH TRIANGLE PARK OFFICE (91 9) 549-1 955 bul-296a.2-20000502 SUBJECT 296A -Al - OCTOBER 18,2000 APPENDIX A PROPOSED REQUIREMENTS AND PROPOSED EFFECTIVE
13、 DATES FOR THE SECOND EDITION OF THE STANDARD FOR WASTE OIL-BURNING AIR-HEATING APPLIANCES, UL 296A For your convenience in review, proposed additions to existing requirements are shown underlined and proposed deletions are shown thed-e and b) From uninsulated live parts connected to different circu
14、its or opposite-polarity parts of the same circuit. Exception No. 1: This reauirement does not awlv to conductors in enclosures where electric liaht, Dower, and Class 1 conductors are introduced solelv to connect the eaubment to Class 2 or Class 3 circuits where the electric liaht, Dower, or Class 1
15、 circuit conductors are routed to maintain at least 1/4 inch soacina to the Class 2 and Class 3 circuit conductors. SUBJECT 296A -A6- OCTOBER 18,2000 Exception No. 2: This reauirement does not awlv when the electric liaht, Dower, or Class 1 circuit operates at 150 volts or less. the around and to Cl
16、ass 2 and Class 3 circuits are installed usina TvDes CL3. CL3. or CL3P wirina materials. and the conductor lenath extendina bevond the insulation of the wirina material is spaced at least 1/4 inch from all other conductors. 9.1 revised (date of publication) 6. GROUNDING SYMBOL RATIONALE UL proposes
17、to allow the use of the IEC grounding symbol to identify equipment-grounding terminals. This symbol has become familiar globally, and meets the intent of the current requirements. This addition corresponds with Section 250-1 19 of the National Electrical Code, ANSVNFPA-70. UL proposes these revision
18、s become effective upon publication. IMPACT Adoption of this proposal would not require a review of presently Listed heating equipment as manufacturers would be provided with the option of using the IEC grounding symbol to identify equipment-grounding terminals. PROPOSALS 10.18 A wire-binding screw
19、intended for the connection of an equipment grounding conductor shall have a green colored head that is hexagonal-shaped, slotted, or both. A pressure wire connector intended for the connection of an equipment grounding conductor shall be identified by being marked ”G”, ”GR”, ”GROUND”, or ”GROUNDING
20、”, or with the aroundina svmbol illustrated in Fiaure 10.1 or by a marking on a wiring diagram provided on the equipment. The wire-binding screw or pressure wire connector shall be secured to the frame or enclosure and shall be located so that it will not need to be removed during servicing. For a w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL296ABULLETIN2000ULSTANDARDFORSAFETYWASTEOILBURNINGAIRHEATINGAPPLIANCESPDF

链接地址:http://www.mydoc123.com/p-439170.html