ANSI ISA 50.00.01-1975 Compatibility of Analog Signals for Electronic Industrial Process Instruments《电子工业加工仪器用模拟信号的兼容性》.pdf
《ANSI ISA 50.00.01-1975 Compatibility of Analog Signals for Electronic Industrial Process Instruments《电子工业加工仪器用模拟信号的兼容性》.pdf》由会员分享,可在线阅读,更多相关《ANSI ISA 50.00.01-1975 Compatibility of Analog Signals for Electronic Industrial Process Instruments《电子工业加工仪器用模拟信号的兼容性》.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、 AMERICAN NATIONAL STANDARD ANSI/ISA-50.00.01-1975 (R2012) Compatibility of Analog Signals for Electronic Industrial Process Instruments Approved 17 July 2012 ANSI/ISA-50.00.01-1975 (R2012) Compatibility of Analog Signals for Electronic Industrial Process Instruments ISBN: 978-1-937560-54-6 Copyrigh
2、t 2012 by the International Society of Automation (ISA). All rights reserved. Not for resale. Printed in the United States of America. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means (electronic mechanical, photocopying, recordi
3、ng, or otherwise), without the prior written permission of the Publisher. ISA 67 Alexander Drive P.O. Box 12277 Research Triangle Park, North Carolina 27709 - 3 - ANSI/ISA-50.00.01-1975 (R2012) Preface This preface, as well as all footnotes and annexes, is included for information purposes and is no
4、t part of ANSI/ISA-50.00.01-1975 (R2012). This document has been prepared as part of the service of ISA toward a goal of uniformity in the field of instrumentation. To be of real value, this document should not be static but should be subject to periodic review. Toward this end, the Society welcomes
5、 all comments and criticisms and asks that they be addressed to the Secretary, Standards and Practices Board; ISA; 67 Alexander Drive; P. O. Box 12277; Research Triangle Park, NC 27709; Telephone (919) 549-8411; Fax (919) 549-8288; E-mail: standardsisa.org. The ISA Standards and Practices Department
6、 is aware of the growing need for attention to the metric system of units in general, and the International System of Units (SI) in particular, in the preparation of instrumentation standards. The Department is further aware of the benefits to USA users of ISA standards of incorporating suitable ref
7、erences to the SI (and the metric system) in their business and professional dealings with other countries. Toward this end, this Department will endeavour to introduce SI-acceptable metric units in all new and revised standards, recommended practices, and technical reports to the greatest extent po
8、ssible. IEEE/ASTM SI 10, American National Standard for Metric Practice, and future revisions, will be the reference guide for definitions, symbols, abbreviations, and conversion factors. It is the policy of ISA to encourage and welcome the participation of all concerned individuals and interests in
9、 the development of ISA standards, recommended practices, and technical reports. Participation in the ISA standards-making process by an individual in no way constitutes endorsement by the employer of that individual, of ISA, or of any of the standards, recommended practices, and technical reports t
10、hat ISA develops. CAUTION ISA DOES NOT TAKE ANY POSITION WITH RESPECT TO THE EXISTENCE OR VALIDITY OF ANY PATENT RIGHTS ASSERTED IN CONNECTION WITH THIS DOCUMENT, AND ISA DISCLAIMS LIABILITY FOR THE INFRINGEMENT OF ANY PATENT RESULTING FROM THE USE OF THIS DOCUMENT. USERS ARE ADVISED THAT DETERMINAT
11、ION OF THE VALIDITY OF ANY PATENT RIGHTS, AND THE RISK OF INFRINGEMENT OF SUCH RIGHTS, IS ENTIRELY THEIR OWN RESPONSIBILITY. PURSUANT TO ISAS PATENT POLICY, ONE OR MORE PATENT HOLDERS OR PATENT APPLICANTS MAY HAVE DISCLOSED PATENTS THAT COULD BE INFRINGED BY USE OF THIS DOCUMENT AND EXECUTED A LETTE
12、R OF ASSURANCE COMMITTING TO THE GRANTING OF A LICENSE ON A WORLDWIDE, NON-DISCRIMINATORY BASIS, WITH A FAIR AND REASONABLE ROYALTY RATE AND FAIR AND REASONABLE TERMS AND CONDITIONS. FOR MORE INFORMATION ON SUCH DISCLOSURES AND LETTERS OF ASSURANCE, CONTACT ISA OR VISIT WWW.ISA.ORG/STANDARDSPATENTS.
13、 OTHER PATENTS OR PATENT CLAIMS MAY EXIST FOR WHICH A DISCLOSURE OR LETTER OF ASSURANCE HAS NOT BEEN RECEIVED. ISA IS NOT RESPONSIBLE FOR IDENTIFYING PATENTS OR PATENT APPLICATIONS FOR WHICH A LICENSE MAY BE REQUIRED, FOR CONDUCTING INQUIRIES INTO THE LEGAL VALIDITY OR SCOPE OF PATENTS, OR DETERMINI
14、NG WHETHER ANY LICENSING TERMS OR CONDITIONS PROVIDED IN CONNECTION WITH SUBMISSION OF A LETTER OF ASSURANCE, IF ANY, OR IN ANY LICENSING AGREEMENTS ARE REASONABLE OR NON-DISCRIMINATORY. ANSI/ISA-50.00.01-1975 (R2012) - 4 - ISA REQUESTS THAT ANYONE REVIEWING THIS DOCUMENT WHO IS AWARE OF ANY PATENTS
15、 THAT MAY IMPACT IMPLEMENTATION OF THE DOCUMENT NOTIFY THE ISA STANDARDS AND PRACTICES DEPARTMENT OF THE PATENT AND ITS OWNER. ADDITIONALLY, THE USE OF THIS DOCUMENT MAY INVOLVE HAZARDOUS MATERIALS, OPERATIONS OR EQUIPMENT. THE DOCUMENT CANNOT ANTICIPATE ALL POSSIBLE APPLICATIONS OR ADDRESS ALL POSS
16、IBLE SAFETY ISSUES ASSOCIATED WITH USE IN HAZARDOUS CONDITIONS. THE USER OF THIS DOCUMENT MUST EXERCISE SOUND PROFESSIONAL JUDGMENT CONCERNING ITS USE AND APPLICABILITY UNDER THE USERS PARTICULAR CIRCUMSTANCES. THE USER MUST ALSO CONSIDER THE APPLICABILITY OF ANY GOVERNMENTAL REGULATORY LIMITATIONS
17、AND ESTABLISHED SAFETY AND HEALTH PRACTICES BEFORE IMPLEMENTING THIS DOCUMENT. THE USER OF THIS DOCUMENT SHOULD BE AWARE THAT THIS DOCUMENT MAY BE IMPACTED BY ELECTRONIC SECURITY ISSUES. THE COMMITTEE HAS NOT YET ADDRESSED THE POTENTIAL ISSUES IN THIS VERSION. The following individuals served as mem
18、bers of the 1975 ISA50 committee: NAME COMPANY V. Tivy, Chairman Bailey Meter Company M. Bergston Barber-Coleman Company D. Boyd Universal Oil Products Company C. Buehler Taylor Instrument Division, Sybron Corporation R. Dallimonti Honeywell Inc. E. Davis Consultant R. Deuschle Fisher Controls Corpo
19、ration M. Bradner The Foxboro Company R. Horne Beckman Instruments, Inc. E. Ida E.I du Pont de Nemours also see Annex A.) 4.5.1 “Fully Isolated“ shall mean that the power, output and electrical signal input terminals (where provided) are all electrically isolated from each other. - 13 - ANSI/ISA-50.
20、00.01-1975 (R2012) Figure 1 Consideration of transmitter types ANSI/ISA-50.00.01-1975 (R2012) - 14 - Figure 2 Consideration of electrical isolation for transmitters - 15 - ANSI/ISA-50.00.01-1975 (R2012) 4.5.2 “Input Isolated“ shall mean that the signal input terminals are electrically isolated from
21、all other terminals. 4.5.3 “Output Isolated“ shall mean that the output terminals are electrically isolated from all other terminals. 4.5.4 “Power Isolated“ shall mean that the power terminals are electrically isolated from all other terminals. 4.5.5 “Electrically Isolated“ in the above definition i
22、s used per the meaning in 2.11. 4.5.6 “Non-Isolated“ shall mean that electrical connections exist internally or externally between all terminals. 4.5.7 “Grounded Output“ shall mean that one side of the output signal will normally become grounded through the instrument mounting unless it is intention
23、ally isolated from earth ground. 4.6 Ripple and noise content The peak to peak ripple and total noise level shall not exceed 0.25% of the maximum signal. This is further defined as not exceeding 10 mV peak to peak on a 5 volt signal (derived by resistive drop from a 20 mA signal, or a voltage signal
24、) when measured at the output of a 10 Hz low pass, single stage R-C filter and when operated from a dc test power source having the maximum allowed ripple and noise permitted in 6.5.2, or from its normal ac power supply. (See Annex A.) 5 Standard receivers 5.1 Inputs 5.1.1 Conversion of a standard c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIISA5000011975COMPATIBILITYOFANALOGSIGNALSFORELECTRONICINDUSTRIALPROCESSINSTRUMENTS 电子工业 加工 仪器 模拟

链接地址:http://www.mydoc123.com/p-436907.html