ANSI INCITS ISO IEC 19794-9-2011 Information technology - Biometric data interchange formats - Part 9 Vascular image data.pdf
《ANSI INCITS ISO IEC 19794-9-2011 Information technology - Biometric data interchange formats - Part 9 Vascular image data.pdf》由会员分享,可在线阅读,更多相关《ANSI INCITS ISO IEC 19794-9-2011 Information technology - Biometric data interchange formats - Part 9 Vascular image data.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、 INCITS/ISO/IEC 19794-9:2011 2013 ISO/IEC 19794-9:2011 Information technology Biometric data interchange formats Part 9: Vascular image data INCITS/ISO/IEC 19794-9:2011 2013 PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be prin
2、ted or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no li
3、ability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is
4、 suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. Adopted by INCITS (InterNational Committee for Information Technology Standards) as an American National Standard. Date of ANSI Appr
5、oval: 6/26/2013 Published by American National Standards Institute, 25 West 43rd Street, New York, New York 10036 Copyright 2013 by Information Technology Industry Council (ITI). All rights reserved. These materials are subject to copyright claims of International Standardization Organization (ISO),
6、 International Electrotechnical Commission (IEC), American National Standards Institute (ANSI), and Information Technology Industry Council (ITI). Not for resale. No part of this publication may be reproduced in any form, including an electronic retrieval system, without the prior written permission
7、 of ITI. All requests pertaining to this standard should be submitted to ITI, 1250 Eye Street NW, Washington, DC 20005. Printed in the United States of America ii ITIC 2013 All rights reserved ISO/IEC 19794-9:2011(E) ISO/IEC 2011 All rights reserved iiiContents Page Foreword iv Introduction . v 1 Sc
8、ope 1 2 Conformance . 1 3 Normative reference 2 4 Terms and definitions . 2 5 Abbreviated terms . 2 6 Data conventions . 3 6.1 Byte and bit ordering 3 6.2 Scan sequence 3 7 Image capture requirements 3 7.1 Spatial sampling rate 3 7.2 Bit-depth . 3 7.3 Illumination 3 7.4 Pixel aspect ratio . 4 7.5 No
9、rmalization of projection 4 7.6 Image storage format 4 7.7 Imaging area 4 7.8 Standard pose 5 7.9 Object coordinate system. 6 7.10 Occlusion by opaque artifacts . 7 8 Vascular image format specification . 7 8.1 Biometric Data Record 7 8.2 General Header 8 8.3 Representation header 9 8.4 Extended dat
10、a 15 9 Registered Format Type Identifier . 18 Annex A (normative) Conformance Testing Methodology . 19 Annex B (informative) A sample image data packet . 20 ISO/IEC 19794-9:2011(E) iv ISO/IEC 2011 All rights reservedForeword ISO (the International Organization for Standardization) and IEC (the Inter
11、national Electrotechnical Commission) form the specialized system for worldwide standardization. National bodies that are members of ISO or IEC participate in the development of International Standards through technical committees established by the respective organization to deal with particular fi
12、elds of technical activity. ISO and IEC technical committees collaborate in fields of mutual interest. Other international organizations, governmental and non-governmental, in liaison with ISO and IEC, also take part in the work. In the field of information technology, ISO and IEC have established a
13、 joint technical committee, ISO/IEC JTC 1. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of the joint technical committee is to prepare International Standards. Draft International Standards adopted by the joint technical comm
14、ittee are circulated to national bodies for voting. Publication as an International Standard requires approval by at least 75 % of the national bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not b
15、e held responsible for identifying any or all such patent rights. ISO/IEC 19794-9 was prepared by Technical Committee ISO/TC JTC1, Information technology, Subcommittee SC 37, Biometrics. This second edition cancels and replaces the first edition (ISO/IEC 19794-9:2007), Clause 8 and Annex A of which
16、have been technically revised. ISO/IEC 19794 consists of the following parts, under the general title Information technology Biometric data interchange formats: Part 1: Framework Part 2: Finger minutiae data Part 3: Finger pattern spectral data Part 4: Finger image data Part 5: Face image data Part
17、6: Iris image data Part 7: Signature/sign time series data Part 8: Finger pattern skeletal data Part 9: Vascular image data Part 10: Hand geometry silhouette data Part 11: Signature/sign processed dynamic data Part 13: Voice Data Part 14: DNA data ISO/IEC 19794-9:2011(E) ISO/IEC 2011 All rights rese
18、rved vIntroduction Vascular biometric technologies have existed for many years. Additionally, new technologies employing vascular images obtained from various parts of the human body are emerging or under continuous improvement as a result of new, state-of-the-art imaging devices. Some of them are b
19、eing widely adopted as reliable biometric modalities. Currently however, little vascular biometric image information is being exchanged between the equipment and devices from different vendors. This is due in part to the lack of standardized formats for information exchange that would ensure interop
20、erability among the various vendors. The purpose of this part of ISO/IEC 19794 is to define a standard for the exchange of human vascular biometric image information. It defines specific attributes, a data record format for storing and transmitting vascular biometric images and certain attributes, a
21、 sample record, and conformance criteria. This part of ISO/IEC 19794 is intended for applications requiring the exchange of raw or processed vascular biometric images. It is intended for applications not limited by the amount of storage required. It is a compromise or a trade-off between the resourc
22、es required for data storage or transmission and the potential for improved data quality/accuracy. Basically, it is to enable various algorithms to identify or verify the vascular biometric image data transferred from other image sources. Currently available vascular biometric technologies that may
23、utilize this part of ISO/IEC 19794 for image exchange are technologies that use the back of the hand, palm, and finger. The use of captured source images can provide interoperability among and between vendors relying on various different recognition or verification algorithms. Accordingly, data from
24、 the captured vascular biometric image offers the developer more freedom in choosing or combining a comparison subsystem. INTERNATIONAL STANDARD ISO/IEC 19794-9:2011(E) ISO/IEC 2011 All rights reserved 1Information technology Biometric data interchange formats Part 9: Vascular image data 1 Scope Thi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIINCITSISOIEC1979492011INFORMATIONTECHNOLOGYBIOMETRICDATAINTERCHANGEFORMATSPART9VASCULARIMAGEDATAPDF

链接地址:http://www.mydoc123.com/p-436327.html