ANSI IEEE 1349-2011 Guide for the Application of Electric Motors in Class I Division 2 and Class I Zone 2 Hazardous (Classified) Locations《I级区域2和I级2区危险(分类)场所使用电动机应用指南》.pdf
《ANSI IEEE 1349-2011 Guide for the Application of Electric Motors in Class I Division 2 and Class I Zone 2 Hazardous (Classified) Locations《I级区域2和I级2区危险(分类)场所使用电动机应用指南》.pdf》由会员分享,可在线阅读,更多相关《ANSI IEEE 1349-2011 Guide for the Application of Electric Motors in Class I Division 2 and Class I Zone 2 Hazardous (Classified) Locations《I级区域2和I级2区危险(分类)场所使用电动机应用指南》.pdf(123页珍藏版)》请在麦多课文档分享上搜索。
1、g3g3g3IEEE Guide for the Application of Electric Motors in Class I, Division 2 and Class I, Zone 2 Hazardous (Classified) Locations IEEE Industry Applications Society SPg3ponsored by the etroleum and Chemical Industry Committee IEEE 3 Park Avenue New York, NY 10016-5997 USA 9 December 2011IEEE Std 1
2、349g4862011 (Revision of IEEE Std 1349-2001) IEEE Std 1349-2011 (Revision of IEEE Std 1349-2001) IEEE Guide for the Application of Electric Motors in Class I, Division 2 and Class I, Zone 2 Hazardous (Classified) Locations Sponsor Petroleum and Chemical Industry Committee of the IEEE Industry Applic
3、ations Society Approved 10 September 2011 IEEE-SA Standards Board Approved 3 December 2012 American National Standards Institute CreditsGrateful acknowledgment is made to the following organizations for granting permission to reprint excerpts, figures, and tables in this guide: Excerpts reprinted wi
4、th permission from NFPA 70-2011, National Electrical Code, Copyright 2011, National Fire Protection Association, Quincy, MA. This reprinted material is not the complete and official position of the NFPA on the reference subject that is represented only by the standard in its entirety. Excerpts repri
5、nted with permission from NFPA 497 Recommended Practice for Classification of Flammable Liquids, Gases or Vapors and of Hazardous (Classified) Locations for Electrical Installations in Chemical Process Areas, Copyright 2008, National Fire Protection Association, Quincy, MA. This reprinted material i
6、s not the complete and official position of the NFPA on the reference subject, which is represented only by the standard in its entirety. Figures 2, 4, 5, 6, 8, G.1, and G.2 Courtesy of General Electric. Figure 3, Courtesy of Marathon Electric. Figure 7, Courtesy of Teco Westinghouse Motor Company.
7、Table C.2, Reprinted with permission from NFPA 70-2011, National Electrical Code, Copyright 2011, National Fire Protection Association, Quincy, MA. This reprinted material is not the complete and official position of the NFPA on the reference subject which is represented only by the standard in its
8、entirety. Tables H.1 and H.2 from Hamer, P. S., Wood, B. M., Doughty, R. L., Gravell, R. L., Hasty, R. C., Wallace, S. E., and Tsao, J. P., “Flammable vapor ignition initiated by hot rotor surface within an induction motorreality or not? PCIC Conference Record, pp. 3747, 1997, Copyright 1997 IEEE. A
9、bstract: Three-phase and single-phase AC synchronous and induction electric motors in ratings 0.18 kW (1/4 hp) and larger are covered in this guide. Primary emphasis is on the use of open or nonexplosionproof or nonflameproof enclosed motors in Class I, Division 2 and Class I, Zone 2 locations as co
10、vered in NFPA 70-2011. Surface temperature test methods and sine wave and non-sine wave applications are covered. Precautions against excessive surface temperatures and sparking are included. To mitigate hot surface temperatures and sparking, this document provides guidance for selecting, operating,
11、 and maintaining motors in Class I, Division 2 and Class I, Zone 2 locations. This guide does not cover AC wound rotor motors and DC electric motors. Motors installed in locations other than Class I, Division 2 and Class I, Zone 2 as covered in NFPA 70-2011 are not covered in this guide. This docume
12、nt is not a specification and is not intended to be used as a specification for purchasing motors. The voltage breaks in this document are 1000 V and less, and over 1000 V. Keywords: adjustable speed drive; autoignition temperature; Class I, Division 2; Class I, Zone 2; classified locations; enclosu
13、re sparking; hazardous locations; IEEE 1349; induction motor; label test; motor; motor enclosure; motor temperature; multisection motor; paint test; rotor; rotor sparking; rotor temperature; synchronous motor; T Code; temperature code g120The Institute of Electrical and Electronics Engineers, Inc. 3
14、 Park Avenue, New York, NY 10016-5997, USA Copyright 2011 by the Institute of Electrical and Electronics Engineers, Inc. All rights reserved. Published 9 December 2011. Printed in the United States of America. IEEE is a registered trademark in the U.S. Patent +1 978 750 8400. Permission to photocopy
15、 portions of any individual standard for educational classroom use can also be obtained through the Copyright Clearance Center. v Copyright 2011 IEEE. All rights reserved. IntroductionThis introduction is not part of IEEE Std 1349-2011, IEEE Guide for the Application of Electric Motors in Class I, D
16、ivision 2 and Class I, Zone 2 Hazardous (Classified) Locations. This guide was developed to assist individuals, organizations, and suppliers with the application of motors in Class I, Division 2 and Class I, Zone 2 locations, where flammable gases and vapors may occasionally be present. Notice to us
17、ers Laws and regulations Users of these documents should consult all applicable laws and regulations. Compliance with the provisions of this standard does not imply compliance to any applicable regulatory requirements. Implementers of the standard are responsible for observing or referring to the ap
18、plicable regulatory requirements. IEEE does not, by the publication of its standards, intend to urge action that is not in compliance with applicable laws, and these documents may not be construed as doing so. Copyrights This document is copyrighted by the IEEE. It is made available for a wide varie
19、ty of both public and private uses. These include both use, by reference, in laws and regulations, and use in private self-regulation, standardization, and the promotion of engineering practices and methods. By making this document available for use and adoption by public authorities and private use
20、rs, the IEEE does not waive any rights in copyright to this document. Updating of IEEE documents Users of IEEE standards should be aware that these documents may be superseded at any time by the issuance of new editions or may be amended from time to time through the issuance of amendments, corrigen
21、da, or errata. An official IEEE document at any point in time consists of the current edition of the document together with any amendments, corrigenda, or errata then in effect. In order to determine whether a given document is the current edition and whether it has been amended through the issuance
22、 of amendments, corrigenda, or errata, visit the IEEE Standards Association web site at http:/ieeexplore.ieee.org/xpl/standards.jsp, or contact the IEEE at the address listed previously. For more information about the IEEE Standards Association or the IEEE standards development process, visit the IE
23、EE-SA web site at http:/standards.ieee.org. ErrataErrata, if any, for this and all other standards can be accessed at the following URL: http:/standards.ieee.org/findstds/errata/index.html. Users are encouraged to check this URL for errata periodically. vi Copyright 2011 IEEE. All rights reserved. I
24、nterpretationsCurrent interpretations can be accessed at the following URL: http:/standards.ieee.org/findstds/interps/ index.html. PatentsAttention is called to the possibility that implementation of this guide may require use of subject matter covered by patent rights. By publication of this guide,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIIEEE13492011GUIDEFORTHEAPPLICATIONOFELECTRICMOTORSINCLASSIDIVISION2ANDCLASSIZONE2HAZARDOUSCLASSIFIEDLOCATIONSI

链接地址:http://www.mydoc123.com/p-435031.html