1、Designation: F2141 07 (Reapproved 2013) An American National StandardStandard Test Method forPerformance of Self-Serve Hot Deli Cases1This standard is issued under the fixed designation F2141; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method evaluates the energy consumption andperformance of self-serve hot deli cases. T
3、he food serviceoperator can use this evaluation to select a deli case andunderstand its energy consumption and performance.1.2 This test method is applicable to electric, fully open orpartially open, hot deli cases that have been designed to holdand merchandise prepackaged hot food. For staff-serve
4、hot delicases, refer to Test Method F2472.1.3 The deli case can be evaluated with respect to thefollowing (where applicable):1.3.1 Energy input rate (10.2),1.3.2 Energy and temperature at the minimum setting(10.3),1.3.3 Energy and temperature at the maximum setting(10.3),1.3.4 Energy and temperature
5、 at the manufacturers recom-mended setting (10.3),1.3.5 Holding capacity (10.4),1.3.6 Holding temperature calibration (10.4),1.3.7 Preheat energy rate (10.5),1.3.8 Idle energy rate (10.6), and1.3.9 Holding energy rate (10.7).1.4 The values stated in inch-pound units are to be regardedas standard. Th
6、e values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard t
7、o establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A36/A36M Specification for Carbon Structural SteelF2472 Test Method for Performance of Staff-Serve Hot DeliCases3. Terminology3.1 ca
8、librated temperature, ntemperature setting at whichthe lowest temperature of the water in the holding pans is at142 6 2F (61 6 1C).3.2 capacity, nthe amount of16 size containers the delicase will hold in a single layer at one time.3.3 deli case, nan appliance designed for the display ofhot food prod
9、uct.3.4 energy input rate, npeak rate at which a deli caseconsumes energy (kW), typically reflected during preheat.3.5 factory setting, nrecommended control setting by themanufacturer.3.6 holding energy, nenergy consumed by the deli case asit is used to hold cooked food product under full loadcondit
10、ions.3.7 holding energy rate, naverage rate of energy con-sumption (kW) during the holding energy tests.3.8 idle energy rate, nthe rate of energy consumed (kW)by the deli case while “holding” or maintaining the heatedsurface at the thermostat set point.3.9 maximum setting, nsetting at which maximum
11、surfacetemperature is achieved.3.10 minimum setting, nsetting at which minimum surfacetemperature is achieved.3.11 preheat energy, namount of energy consumed by thedeli case while preheating the heated surface from ambientroom temperature (75 6 5F (24 6 3C) to a temperature atthe calibrated setting.
12、3.12 preheat rate, naverage rate (F/min (C/min) atwhich the deli cases holding surface is heated from ambient1This test method is under the jurisdiction of ASTM Committee F26 on FoodService Equipment and is the direct responsibility of Subcommittee F26.06 onProductivity and Energy Protocol.Current e
13、dition approved June 1, 2013. Published August 2013. Originallyapproved in 2001. Last previous edition approved in 2007 as F2141 07. DOI:10.1520/F2141-07R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of AS
14、TMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1temperature (75 6 5F (24 6 3C) to holding temperaturewith the thermostat set to the calibr
15、ated setting.3.13 preheat time, ntime required for the deli case topreheat from ambient room temperature (75 6 5F (24 63C) to the calibrated setting.3.14 uncertainty, nmeasure of systematic and precisionerrors in specified instrumentation or measure of repeatabilityof a reported test result.4. Summa
16、ry of Test Method4.1 The deli case is connected to the appropriate meteredenergy source, and energy input rate is determined to confirmthat the appliance is operating within 5 % of the nameplateenergy input rate.4.2 The deli case holding surface is monitored at maximum,minimum, and factory recommend
17、ed (if provided) settingsusing a predetermined number of 5-in. (127-mm) metal discsdistributed equally over the heating surface of the deli case.4.3 Capacity is determined by loading the deli case full of16size containers.4.4 The calibrated setting is determined by using16 sizeplastic pans filled wi
18、th water and setting the surface tempera-ture of the deli case such that lowest temperature in the watercontainers is 142 6 2F (61 6 1C).4.5 The amount of energy and time required to preheat thedeli case to calibrated setting is determined.4.6 The idle energy rate is determined with the deli case se
19、tat calibrated setting.4.7 The deli case is used to hold16 size containers filledwith hot food for 3 h. Food temperature and deli case energyconsumption are monitored during this testing.5. Significance and Use5.1 The energy input rate is used to confirm that the delicase is operating properly prior
20、 to further testing.5.2 Holding temperature range is useful for food serviceoperators in selecting a unit that matches their holding require-ments.5.3 Capacity is used by food service operators to choose adeli case that matches their food holding requirements.5.4 Preheat energy and time can be usefu
21、l to food serviceoperators to manage energy demands and to know how quicklythe deli case can be ready for operation.5.5 Holding energy rate and idle energy rate can be used bythe food service operator to estimate deli case energy consump-tion.6. Apparatus6.1 Analytical Balance Scale, for measuring w
22、eights up to20 lb (9 kg), with a resolution of 0.01 lb (0.004 kg) and anuncertainty of 0.01 lb (0.004 kg).6.2 Data Acquisition System, for measuring energy andtemperatures, capable of multiple channel displays updating atleast every 2 s.6.3 Metal Discs, (one for each hexagonal section of the delicas
23、e or one for each square foot of the deli case) composed ofstructural-grade carbon steel in accordance to SpecificationA36/A36M, free of rust or corrosion, 5 in. (127 mm) indiameter, and14 in. (6 mm) thick. The discs shall be flat towithin 0.010 in. (0.2 mm) over the diameter.6.4 Strain Gage Welder,
24、 capable of welding thermocouplesto steel.6.5 Thermocouple(s), industry standard type T or type Kthermocouple wire with a range of 0 to 250F (18 to 121C)and an uncertainty of 61F (60.56C).6.6 Thermocouple Probe, “fast response” type T or type Kthermocouple probe,116-in. or smaller diameter, with a 3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF21412007STANDARDTESTMETHODFORPERFORMANCEOFSELFSERVEHOTDELICASES 熟食 加热 装置 性能 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-433035.html