1、 A-A-59278 m 9038054 0003325 462 9 INCH-POUND Juiy 1,1998 A-A-59278 COMMERCIAL ITEM DESCRIPTION OSCILLOSCOPE (Digital Storage, 1 GHz) The General Services Administration has authorized the use of this Commercial Item Description for all federal agencies. 1. SCOPE. This Commercial Item Description (C
2、ID) outlines the minimum requirements for a four-channel, 1 GHz digital storage oscilloscope. The digital storage oscilloscope provided shall be commercially-available test equipment capable of being portable or modified with a rackmount kit to be included in a rackmount assembly. Only those product
3、s that meet or exceed the requirements outlined in this CID are acceptable. 2. SALIENT cHARJ4cTERIsTIcs 2.1. Class 3 equipment. Unless otherwise specified, the oscilloscope covered by this CID is categorized as Class 3 test equipment in accordance with the latest version of MIL-PRF-28800F. 2.2. Safe
4、ty and environmental. The oscilloscope shall meet all safety and environmental requirements as specified in MILPRF-28800F when used as bench-top or rackmount equipment. 2.3. Electrical power sources. The power consumption of all components combined shall not exceed 400 VA and the oscilloscope shall
5、operate from nominal commercial military, and shipboard power sources over the following ranges: at 110/120 Volts rms (+ 5 percent), single phase at frequencies of 50,60, and 400 Hertz (Hz) and 200/240 Volts rms (t 5 percent) single phase at line frequencies of 50 and 60 Hz. The oscilloscope shall o
6、perate in accordance with steady state conditions, transient state conditions, and interruption of power source requirements outlined in MIL- PRF-288OOF. 2.4. Accessories. Accessories to be supplied by the manufacturer with each deliverable oscilloscope shall include standard accessories as provided
7、 by the manufacturer and listed in the manufacturers catalog or data sheet, a written tutorialhser reference manual, a written programmer reference manual, and a traceable calibration certificate. 2.4.1. Cover. The oscilloscope enclosure shall have a cover protecting the front panel controls and dis
8、play in accordance with MIL-PRF-28800F. Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any data which may improve this document should be sent to: The Resources and Logistics Services Center, SA-AL,C/ITLDD, Bldg. 171, Post A-16,485 Quentin Roosevelt Rd., Kelly
9、AFB, TX 78241-6425, by using the enclosed Form DD 1426, I Standardization Document Improvement Proposal, appearing at the end of this document. AMSC NIA FSC 6625 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59278 2.4.2. Probes. The active or p
10、assive probes provided for both channels will permit an input signal attenuation of 1 and 10 over the full 1 GHz bandwidth and vertical accuracy. The probe attenuation shall be automatically recognized and the scale factor of the oscilloscope adjusted appropriately. 2.5. Interface. The oscilloscope
11、shall be capable of interfacing with industry standard data interchange formats for files, formats, storage, communications, plotting, and printing. 2.5.1. ANSUIEEE-STD-488 Interface Requirements. The oscilloscope?s digital interface shall control each device function including all ranges, modes, an
12、d levels except for primary power control and other non-measurement functions as required by MILPRF-28800F, paragraph 3.4.1. 2.5.2. Output Ports. The oscilloscope shall have RS-232 interface that complies with EIALIA 574 talk, talk only, and tawisten commands and Centronics interface complying with
13、C332-44, Feb. 1977, Rev. A, for printer andor plotter outputs. 2.5.3. Printer Interface. The oscilloscope shall have the minimum capability of interfacing with Laser and Epson or a similar style printer. 2.5.4. File Formats. The oscilloscope shall have, at the least, capability of providing, storing
14、, and transfemng data in TIFF and BMP image formats. 2.5.5. Data Format. The oscilloscope shall have the ability to process data with MathCADm or similar software. 2.6. Rackmount Option. If specified in the contract or order, the oscilloscope shall be delivered with an attachable raclanount kit whic
15、h includes the necessary accessories and hardware to interconnect all front and rear panel input and output ports and include any filler panels to provide the preferred height and width if required. Conversion to a rack-mounted configuration shall be accomplished by use of a kit that converts the en
16、closure, but will not prevent return to the original configuration. 2.7. Dimensions and Weight. The oscilloscope dimensions shall permit the oscilloscope?s inclusion in a standard 19- inch wide rack enclosure with a standard height of less than 6 rack units. The oscilloscope?s weight, including the
17、front cover and all accessones (excluding written manuals) shall not exceed 48 pounds. 2.8. Preconditioning Requirement. Each deliverable oscilloscope shall be capable of withstanding the environmental screening effects of burn-in and thermal cycling, with thermal cycling being accomplished in the s
18、ample testing phase. 2.9. Self-Test. The oscilloscope shall provide an automatic diagnostic self-test, in accordance with MILPRF-28800F paragraph 3.3.6, automatically upon start-up andor when invoked by the operator either manually or remotely. 2.10. Extended Diagnostics. The oscilloscope shall prov
19、ide extended diagnostic routines to detect internal electrical failures to the next lower level from self test and shall be invoked by front panel controls. 2.11. Signal Path Compensation. The oscilloscope shall provide internai signal path compensation either automatically on start-up andor when in
20、voked remotely or by front panel controls. 2.12. Calibration. The equipment shall meet the requirements for calibration outlined in MILPRF-28800F as weli as the following: 2.12.1. Calibration and Maintenance Adjustments. The oscilloscope shall have an auto calibration feature which ensure specified
21、DC and timing accuracy. Changes in environmental conditions within the operating range of the 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59278 m 90LB054 O003327 235 m A-A-59218 equipment will not require additional calibration, except for
22、internal calibration procedures and signai path compensation, to meet performance requirements. 2.13. Autoset. The oscilloscope shall provide an Autoset function that when activated, will automatically configure the vertical, horizontal, riggerhg, acquisition, and display controls to provide a trigg
23、ered display positioned on a screen. 2.14. Temperature Requirements. The oscilloscope shall meet performance and accuracy requirements in Class 4 operating and non-operating environments. Disk operations shall be required over the range of 10 to 40 degrees C. 2.15. Humidiw. The oscilloscope shall me
24、et performance and accuracy requirements for disk drive operations in a Class 4 operating environment of 5 to 95 percent (I 5 percent) relative humidity from 10 to 30 degrees C.; to 75 percent (I 5 percent) relative humidity at 30 to 40 degrees C.; and 45 percent (I 5 percent) relative humidity abov
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA592781998OSCILLOSCOPEDIGITALSTORAGE1GHZ 示波器 数字 存储 吉赫 PDF

链接地址:http://www.mydoc123.com/p-427074.html