BS PD CEN TS 12390-9-2016 Testing hardened concrete Freeze-thaw resistance with de-icing salts Scaling《硬化混凝土试验 融冰盐抗冻融性 缩放比例》.pdf
《BS PD CEN TS 12390-9-2016 Testing hardened concrete Freeze-thaw resistance with de-icing salts Scaling《硬化混凝土试验 融冰盐抗冻融性 缩放比例》.pdf》由会员分享,可在线阅读,更多相关《BS PD CEN TS 12390-9-2016 Testing hardened concrete Freeze-thaw resistance with de-icing salts Scaling《硬化混凝土试验 融冰盐抗冻融性 缩放比例》.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、PD CEN/TS 12390-9:2016 Testing hardened concrete Part 9: Freeze-thaw resistance with de-icing salts Scaling BSI Standards Publication WB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06PD CEN/TS 12390-9:2016 PUBLISHED DOCUMENT National foreword This Published Document is the UK implementation o
2、f CEN/TS 12390-9:2016. It supersedes DD CEN/TS 12390-9:2006 which is withdrawn. The UK participation in its preparation was entrusted to Technical Committee B/516/12, Sampling In Clauses 5, 6 and 7,(for all test methods), a prescription measuring the CO 2 content of the air in the storage room has b
3、een introduced; In Annex A, the alternative applications have been strictly specified; In Annex B, a technical specification has been introduced; In the Bibliography, the references have been updated. EN 12390, Testing hardened concrete, is currently composed with the following parts: Part 1: Shape,
4、 dimensions and other requirements for specimens and moulds; Part 2: Making and curing specimens for strength tests; Part 3: Compressive strength of test specimens; Part 4: Compressive strength Specification for testing machines; Part 5: Flexural strength of test specimens; Part 6: Tensile splitting
5、 strength of test specimens; Part 7: Density of hardened concrete; Part 8: Depth of penetration of water under pressure; Part 9: Freeze-thaw resistance Scaling Complementary element Technical Specification; Part 10: Determination of the relative carbonation resistance of concrete Technical Specifica
6、tion; Part 11: Determination of the chloride resistance of concrete, unidirectional diffusion; Part 13: Determination of secant modulus of elasticity in compression. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to announ
7、ce this Technical Specification: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Roma
8、nia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. PD CEN/TS 12390-9:2016 CEN/TS 12390-9:2016 (E) 4 Introduction Concrete structures exposed to the effects of freezing and thawing need to be durable to have an adequate resistance to this action and, in cases such as
9、road construction, to freezing and thawing in the presence of de-icing agents. It is desirable, especially in the case of new constituents or new concrete compositions, to test for such properties. This also applies to concrete mixes, concrete products, precast concrete, concrete members or concrete
10、 in situ. There are two types of concrete deterioration when a freezethaw attack occurs, scaling and internal structural damage. Test methods on internal structural damage are described in the CEN Technical Report CEN/TR 15177, Testing the freeze-thaw resistance of concrete Internal structural damag
11、e. Many different test methods have been developed. No single test method can completely reproduce the conditions in the field in all individual cases. Nevertheless, any method should at least correlate to the practical situation and give consistent results. Such a test method may not be suitable fo
12、r deciding whether the resistance is adequate in a specific instance but will provide data of the resistance of the concrete to freezethaw-attack and freezethaw-attack in the presence of de-icing agents. If the concrete has inadequate resistance then the freezethaw attack can lead to two different t
13、ypes of damage, namely to scaling (surface weathering) and to internal structural damage. This part of this standard covers only testing for scaling resistance. This Technical Specification has one reference method and two alternative methods. For routine testing either the reference method or one o
14、f the two alternative methods may be used with the agreement of the parties involved. In case of doubt, and if there is no such agreement, the reference method is used. The testing methods may be used for comparative testing or for assessment against fixed acceptance criteria. The application of lim
15、iting values will require the establishment of the correlation between laboratory results and field experience. Due to the nature of the freezethaw action, such correlation would have to be established in accordance with local conditions, reflected in the national application documents. PD CEN/TS 12
16、390-9:2016 CEN/TS 12390-9:2016 (E) 5 1 Scope This Technical Specification describes the testing of the freezethaw scaling resistance of concrete both with water and with sodium chloride solution. It can be used either to compare new constituents or new concrete compositions against a constituent or
17、a concrete composition that is known to give adequate performance in the local environment or to assess the test results against some absolute numerical values based on local experiences. Extrapolation of test results to assess different concretes, i.e. new constituents or new concrete compositions,
18、 requires an expert evaluation. NOTE In some cases the test methods may not be suitable for testing special concretes e.g. high strength concrete or permeable concrete. In these cases the result needs to be treated with caution. Also, the testing methods included in this document may not identify ag
19、gregates that are subject to occasional pop-outs. There is no established correlation between the results obtained by the three test methods. All tests will clearly identify poor and good behaviour, but they differ in their assessment of marginal behaviour. The application of different acceptance li
20、mits for test results enables assessment for different degrees of exposure severity. In case of justified modifications of the test parameters, precautions might apply. Some alternative applications are described in Annex A. 2 Normative references The following documents, in whole or in part, are no
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDCENTS1239092016TESTINGHARDENEDCONCRETEFREEZETHAWRESISTANCEWITHDEICINGSALTSSCALING 硬化 混凝土 试验 融冰盐抗冻融性

链接地址:http://www.mydoc123.com/p-397433.html