IEEE N449 1-1978 en Procedures for Periodic Inspection of Cobalt - 60 and Cesium - 137 Teletherapy Equipment《钴60和铯137遥控仪器的定期检测程序》.pdf
《IEEE N449 1-1978 en Procedures for Periodic Inspection of Cobalt - 60 and Cesium - 137 Teletherapy Equipment《钴60和铯137遥控仪器的定期检测程序》.pdf》由会员分享,可在线阅读,更多相关《IEEE N449 1-1978 en Procedures for Periodic Inspection of Cobalt - 60 and Cesium - 137 Teletherapy Equipment《钴60和铯137遥控仪器的定期检测程序》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、 ANSI N449.1-1978American National Standard Procedures for Periodic Inspection of Cobalt-60 and Cesium-137 Teletherapy EquipmentSecretariat for N44Institute of Electrical and Electronics Engineers, IncApproved April 7, 1977Reaffirmed August 7, 1984American National Standards InstitutePublished byIns
2、titute of Electrical and Electronics Engineers, Inc345 East 47th Street, New York, NY 10017 Copyright 1978 byThe Institute of Electrical and Electronics Engineers, IncNo part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without theprior written p
3、ermission of the publisher.American National StandardAn American National Standard implies a consensus of those substantially concerned with its scope and provisions.An American National Standard is intended as a guide to aid the manufacturer, the consumer, and the general public.The existence of an
4、 American National Standard does not in any respect preclude anyone, whether he has approved thestandard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures notconforming to the standard. American National Standards are subject to periodic review and users
5、are cautioned toobtain the latest editions.CAUTION NOTICE:This American National Standard may be revised or withdrawn at any time. The procedures ofthe American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard nolater than five years from the d
6、ate of publication. Purchasers of American National Standards may receive currentinformation on all standards by calling or writing the American National Standards Institute.iiiForeword(This foreword is not a part of ANSI N449.1-1978, Procedures for Periodic Inspection of Cobalt-60 and Cesium-137 Te
7、letherapyEquipment.)This guidelines for inspection of teletherapy equipment are the product of Subcommittee N44.2, and its original draftof 1973 was written by Peter Vreeling. Priority for the attention of N44.2 on this subject of periodic inspection wassuggested by the Bureau of Radiological Health
8、 (BRH) of the United States Department of Health, Education andWelfare. For those several early years of N44.2 the BRH was the sponsor of the subcommittee and some of the mostproductive work on this standard (ANSI N449.1-1978) was done at meetings in BRH headquarters. Urgency forpromulgation of stan
9、dards for periodic inspection of teletherapy apparatus was stimulated by a fatality occurring whena patient was crushed by a cobalt teletherapy whose deficiency might have been corrected by appropriate maintenanceand inspection. It is a tribute to teletherapy apparatus, in general, that few serious
10、accidents have been reported withsuch machines which became the “conventional radiotherapy devices” of the 1950s, 1960s and even the 1970s.Complacency can follow decades of safe and dependable use of cobalt and cesium teletherapy machines, and thismaintenance guide is designed to avoid accidents and
11、 inaccuracies of output.When the BRH deemed it in conflict with their bureau to continue sponsorship of N44.2, the subcommittee onstandards for radiotherapy equipment IEEE took on the task of continued sponsorship of N44.2, and the task ofcompletion of this maintenance standard by obtaining final ap
12、proval by formal balloting.Members of N44.2 assisted Peter Vreeling in their numerous reviews and meetings, but the brunt of the work indeveloping N449.1 was borne by Peter Vreeling, himself. Consensus and suggestions of overlapping pertinentstandards from other national and international agencies w
13、ere supplied by members of the subcommittee.N44.2 aimed its efforts toward supplying useful information on periodic inspections of teletherapy apparatus to users(physicians and physicists), manufacturers, and regulators (for example, BRH). During the multiple meetings anddiscussions on safety for te
14、letherapy, the increase in numbers of linear accelerators was recognized, and theimportance of promulgating standards for these complex devices was noted. But the relatively simpler job ofestablishing standards for cobalt teletherapy machines was elected because of the need for such a standard, and
15、also toafford a prototype standard for subsequent promulgation of similarly needed guides for linear accelerators.At the time it approved this standard, American National Standards Committee on Equipment and Materials forMedical Radiation Applications had the following personnel:A. B Brill, MD, PhD,
16、 Chair John Tagler, Secretary American Association for the Advancement of Science N. Suntharalingam, PhDCharles L Dunham, MD (Alt)American Association of Obstetricians and Gynecologists. Clayton T. Beccham, MDGeorge C. Lewis, Jr, MD (Alt)American Association of Physicists in Medicine. Robert M. Quil
17、lin, MPHLeonard Stanton, MS (Alt)American Chiropractic Association Joseph W. Howe, DCT. M. Goodrich, DC (Alt)American Conference of Governmental Industrial Hygienists Gordon LoddeJacqueline Messite, MD (Alt)American College of Physicians Henry N. Wagner, Jr, MDJoseph F. Ross, MD (Alt)American Colleg
18、e of Radiology S. Reid Warren, Jr, ScDArgonne Cancer Research Hospital Katherine A. LathropPaul V. Harper, MD (Alt)American Chemical Society . Ellis P. Steinberg, PhDAmerican Dental Association . Albert G. RichardsLeonard M. Kraske, MD (Alt)American Federation of Labor and Congress of Industrial Org
19、anizations .George TaylorJack Suarz (Alt)Armed Forces Radiobiology Research Institute Lester A. Slaback, JrJohn M. Arras (Alt)American Insurance Association Leo G. FoxwellHarry W. Rapp, Jr (Alt)ivAtomic Industrial Forum, Inc .W. R. Konneker, PhDAmerican Medical Technologists John M. RhodesThomas A.
20、Pence (Alt)American Nuclear Society Herbert M. Parker, PhDAmerican Osteopathic Association. William E. Betts, Jr, PhDRobert R. Rosenbaum, MD (Alt)American Osteopathic College of Radiology . M. Carmen Pettapiece, MDRobert R. Rosenbaum, MD (Alt)American Pharmaceutical Association . William BrinerCharl
21、es H. Barnstein, MD (Alt)American Podiatry AssociationSidney B. Roth MDAmerican Public Health Association Rodney Dean Ice, PhDStanley J. Malsky, PhD (Alt)American Roentgen Ray Society. Charles A. Bickham, Jr, MDHomer L. Twigg, Jr, MD (Alt)American Radium Society . Morris J. Wizenberg, MDAmerican Soc
22、iety of Clinical Pathologists . Welby N. Tauxe, MDAmerican Society of Hospital Pharmacists.Barry M. BowenAmerican Society of Mechanical Engineers Allan B. DrosinAmerican Society for Quality ControlVacantAmerican Society of Radiologic Technologists. John H. Tolan, RTStephen Hiss, RT (Alt)Association
23、of State and Territorial Health Officers.Richard M. FryMartin C. Wukasch (Alt)American Veterinary Medical AssociationFrank A. Todd, MPH, DBMLeo A. Whitehair, DBM, MS, PhD (Alt)Brookhaven National Laboratory.H. Atkins, MDRalph Fairchild, PhD (Alt)Battelle-Northwest Memorial Institute (Nonvoting) Carl
24、os E. Newton, JrH. V. Larson (Alt)Bureau of Radiological Health Marshall S. LittlePeter Paras, PhD (Alt)College of American PathologistsJohn R. Hansell, MDWolfgang Hauser, MD (Alt)Department of Defense Office of the Surgeon.General David H. WoodRobert M. Quillin, MPH (Alt)Electronic Industries Assoc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEEN44911978ENPROCEDURESFORPERIODICINSPECTIONOFCOBALT60ANDCESIUM137TELETHERAPYEQUIPMENT 60 137 遥控 仪器

链接地址:http://www.mydoc123.com/p-1249365.html