IEEE C37 20 7 INT 1-2009 en Guide for Testing Metal-Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults《小于等于38 kV额定电压的内部电弧故障用封装金属开关设备测试指南》.pdf
《IEEE C37 20 7 INT 1-2009 en Guide for Testing Metal-Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults《小于等于38 kV额定电压的内部电弧故障用封装金属开关设备测试指南》.pdf》由会员分享,可在线阅读,更多相关《IEEE C37 20 7 INT 1-2009 en Guide for Testing Metal-Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults《小于等于38 kV额定电压的内部电弧故障用封装金属开关设备测试指南》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、IEEE Standards Interpretations for IEEE Std C37.20.7 -2007 IEEE Guide for Testing Metal-Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults Copyright 2009 by the Institute of Electrical and Electronics Engineers, Inc. Three Park Avenue New York, New York 10016-5997 USA All Rights Reserv
2、ed. This is an interpretation of IEEE Std C37.20.7-2007. Interpretations are issued to explain and clarify the intent of a standard and are not intended to constitute an alteration to the original standard or to supply consulting information. Permission is hereby granted to download and print one co
3、py of this document. Individuals seeking permission to reproduce and/or distribute this document in its entirety or portions of this document must contact the IEEE Standards Department for the appropriate license. Use of the information contained in this document is at your own risk. IEEE Standards
4、Department Copyrights and Permissions 445 Hoes Lane, P. O. Box 1331 Piscataway, New Jersey 08855-1331, USA November 2009 Interpretation Request #1 Topic: Ignition Clause, Subclause, Annex, Figure, or Table: Clause 6.1, Criterion 4 An interpretation of 6.1, Criterion 4 of IEEE Std C37.20.7-2007 is re
5、quested. Under what conditions does ignition of indicators due to glowing particles constitute a FAILURE and when is it a PASS? Criterion 4 states that: “Indicators ignited as a result of the burning of paint or labels, glowing particles, and so on, are excluded“ i.e. it is a PASS when indicators ig
6、nite as a result of glowing particles. Criterion 4 continues with: “Holes in horizontally mounted indicators caused by particles that do not ignite the indicator are ignored.“ This implies that if indicators are ignited by glowing particles it is a Page 1 of 3IEEE Std C37.20.7-200712/4/2009http:/sta
7、ndards.ieee.org/reading/ieee/interp/C37.20.7-2007.htmlFAILURE and contradicts the earlier statement in Criterion 4. An interpretation of term “ignition“ is requested. It is assumed that the definition of “ignition“ in this context requires the presence of a flame which consumes cloth beyond that aff
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEEC37207INT12009ENGUIDEFORTESTINGMETALENCLOSEDSWITCHGEARRATEDUPTO38KVFORINTERNALARCINGFAULTS 小于 等于

链接地址:http://www.mydoc123.com/p-1249073.html