1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMay 11, 20071SUBJECT 50VOUTLINE OF INVESTIGATIONFORINFRARED VIEWPORTSISSUE NUMBER: 1MAY 11, 2007Summary of TopicsThis is the First issue of the Outline of Investigation for InfraredViewports, Sub
2、ject 50V. Infrared (IR) viewports are intended for factoryinstallation in doors or walls of electrical enclosures for installation inordinary (non-hazardous) locations to allow the use of IR scanners formonitoring temperatures of the enclosed equipment on which theviewport is installed, without comp
3、romising the integrity of the enclosurewith respect to access to live parts.The UL Foreword is no longer located within the UL Standard. For informationconcerning the use and application of the requirements contained in thisStandard, the current version of the UL Foreword is located onULStandardsInf
4、oNet at: http:/ 2007 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMAY 11, 2007SUBJECT 50V2No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FR
5、OM ULCONTENTSINTRODUCTION1 Scope .42 Units of Measurement .43 Components 54 Undated References 5CONSTRUCTION5 General 56 Accessibility of Live Parts 67 Covers .68 Metal Frames and Covers 79 Corrosion Protection .810 Spacings 911 Crystal Viewing Panes 912 Polymeric Materials for Frames, Covers or Vie
6、wing Panes 912.1 Polymeric materials closing an opening not more than 1.2 square inches (775 mm2)912.2 Polymeric materials closing an opening greater than 1.2 square inches (775 mm2) . . .1013 Metallic Mesh or Grill Type Viewing Panes .1014 Viewports for Use in Enclosures with Environmental Ratings
7、.1015 Bonding of Conductive Parts .11PERFORMANCE16 General 1117 Flammability 127 mm (5 inch) Flame Test .1118 Resistance to Impact Test .1219 Crushing Resistance Test 1220 Environmental Type Rating Tests .12MARKINGS21 General 12MAY 11, 2007 SUBJECT 50V 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FUR
8、THER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 Infrared (IR) Viewports are a fixed aperture, consisting of one or more openings or a solid infraredtransmitting media, surrounded by a mounting bezel or frame, that provide a means for the passage ofinfrared radiation
9、. Infrared viewports are intended for factory installation in doors or walls of electricalenclosures for installation in ordinary (non-hazardous) locations to allow the use of IR scanners formonitoring temperatures of the enclosed equipment on which the viewport is installed, withoutcompromising the
10、 integrity of the enclosure with respect to access to live parts. Viewports may beinvestigated for installation in Type 1 enclosures or enclosures with other environmental ratings.1.2 Compliance with these requirements does not assure that the infrared viewport is suitable for use asa component of a
11、n end product. For example, accessibility of live parts is investigated with respect toindustrial products rated 600 V and below, and additional investigation may be required for products ratedover 600 V.1.3 The acceptability of an infrared viewport in any particular application depends upon its sui
12、tability forcontinued use under the conditions that prevail in actual service. Accordingly, for a particular applicationan infrared viewport may be affected by the requirements for the equipment in which it is used, and it maybe necessary to additionally evaluate that infrared viewport for features
13、or performance characteristicsthat are not specified in this Outline of Investigation.1.4 These requirements do not cover the field installation of infrared viewports on enclosures of electricalequipment already in service.1.5 These requirements do not cover viewports made from glass or translucent
14、polymeric materialsintended for passage of visible light for observation of internal electrical equipment by operators or servicepersonnel.2 Units of Measurement2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.MAY 11, 2007SUBJ
15、ECT 50V4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3 Components3.1 Except as indicated in 3.2, a component (including gaskets and polymeric materials) of a productcovered by this outline of investigation shall comply with the requirements
16、 for that component.3.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this outline of investigation, orb) Is superseded by a requirement in this outline of inves
17、tigation.3.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.3.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as cer
18、tain temperatures notexceeding specified limits, and shall be used only under those specific conditions.4 Undated References4.1 Any undated reference to a code or standard appearing in the requirements of this outline ofinvestigation shall be interpreted as referring to the latest edition of that co
19、de or standard.CONSTRUCTION5 General5.1 An infrared viewport that forms part of the enclosure shall be reliably secured by hardware suppliedwith the viewport in such a manner that it cannot be readily displaced in service, and shall providemechanical protection for the enclosed parts.5.2 An adhesive
20、 relied upon as the sole means for securing a part closing an opening in an enclosureshall comply with the requirements for adhesives in the Standard for Polymeric Materials Use inElectrical Equipment Evaluations, UL 746C when applied to the materials to be secured.5.3 A sealing compound relied upon
21、 as the sole means for securing a part closing an opening in anenclosure shall comply with 5.2 or the Accelerated Aging Test for sealing compounds described in theStandard for Industrial Control Equipment, UL 508.5.4 All hardware, gaskets, or other parts needed to complete the installation shall be
22、provided with theinfrared viewport.MAY 11, 2007 SUBJECT 50V 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL6 Accessibility of Live Parts6.1 When installed according to the manufacturers instructions, infrared viewports shall comply with ther
23、equirements for Accessibility of Live Parts as described in the Standard for Industrial Control Equipment,UL 508, with the cover in the removed or in the open position.7 Covers7.1 A cover is permitted to be supplied with an infrared viewport to protect the infrared transmitting mediafrom external da
24、mage or to maintain the environmental rating of the enclosure when the viewport is notin use.7.2 When provided, a cover shall be provided with fastening means, such as latches, hinges, locks,screws or equivalent means, for firmly securing it in place.7.3 The cover fastening means shall be operable b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT50V2007OUTLINEOFINVESTIGATIONFORINFRAREDVIEWPORTSISSUE1 红外线 观察 调查 大纲 发布 编号 PDF

链接地址:http://www.mydoc123.com/p-1069453.html