《UL SUBJECT 1821A-2005 Outline of Investigation for Thermoplastic Sprinkler Pipe and Fittings for Low Pressure Dry Pipe Applications (Issue 1)《低压干管用热塑塑料洒水管和配件调查大纲 发布编号 1》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 1821A-2005 Outline of Investigation for Thermoplastic Sprinkler Pipe and Fittings for Low Pressure Dry Pipe Applications (Issue 1)《低压干管用热塑塑料洒水管和配件调查大纲 发布编号 1》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULDecember 16, 20051SUBJECT 1821AOUTLINE OF INVESTIGATIONFORTHERMOPLASTIC SPRINKLER PIPE AND FITTINGS FOR LOW PRESSUREDRY PIPE APPLICATIONSIssue No: 1December 16, 2005Summary of TopicsThis is the F
2、irst issue of the Outline of Investigation for ThermoplasticSprinkler Pipe and Fittings for Low Pressure Dry Pipe Applications. Thisoutline covers thermoplastic pipe and fittings for use in low pressuredry pipe sprinkler systems for fire protection service.COPYRIGHT 2005 UNDERWRITERS LABORATORIES IN
3、C.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULDECEMBER 16, 2005SUBJECT 1821A2No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Units
4、 of Measurement .43 Glossary .4PERFORMANCE4 General 45 Fire Exposure Test 46 Impact Resistance Tests for Low Pressure Dry Systems .56.1 General .56.2 Impact with flat Tup .56.3 Impact with conical shaped tup .67 Temperature Cycling Test 8INSTRUCTIONS8 Installation and Design Manual .8DECEMBER 16, 20
5、05 SUBJECT 1821A 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 This Outline of Investigation covers thermoplastic pipe and fittings for use in low pressure dry pipesprinkler systems for fire protection service. In add
6、ition to the requirements in the Standard forThermoplastic Sprinkler Pipe and Fittings for Fire Protection Service, UL 1821, the following aresupplemental requirements that also apply to thermoplastic pipe and fittings for use in low pressure drypipe sprinkler systems.2 Units of Measurement2.1 Value
7、s stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.3 Glossary3.1 For the purpose of this outline, the following definitions apply.3.2 LOW PRESSURE DRY SYSTEMS A thermoplastic sprinkler piping system containingcompressed air or nitrogen h
8、aving a gage pressure not greater than 15 psig (103 kPa) intended for usein dry systems.3.3 MINIMUM RATED TEMPERATURE The lowest ambient temperature and associated pressurethat the pipe and fittings are intended to be exposed during use, as specified in the manufacturersdesign and installation instr
9、uctions.PERFORMANCE4 General4.1 Pipe and fitting assemblies representing the sizes, limitations and provisions contained in theinstallation and design manual, shall be subjected to the tests described in Sections57.5 Fire Exposure Test5.1 Pipe and fitting assemblies intended for installation in low
10、pressure dry systems without protectivematerials referenced in UL 1821, Section 13.1.1, shall comply with the Fire Exposure Tests described inthe Standard for Thermoplastic Sprinkler Pipe and Fittings for Fire Protection Service, UL 1821, Section13 except the piping shall be initially pressurized wi
11、th air at 15 +0/-1 psig, (103 +0/-7 kPa) and the watersupply to the piping shall be delayed for the time specified in Table 5.1 after sprinkler operation for theoccupancy hazard intended to be protected.DECEMBER 16, 2005SUBJECT 1821A4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
12、DISTRIBUTION WITHOUT PERMISSION FROM ULTable 5.1Dry system water delivery time delayOccupancy hazard* Water delivery delay, sResidential 15Light 60* As described in NFPA 13, Standard for the Installation of Sprinkler Systems.6 Impact Resistance Tests for Low Pressure Dry Systems6.1 General6.1.1 Repr
13、esentative pipe and fitting assemblies shall not shatter or fragment when impacted on the pipesidewall when tested as specified in 6.1.2, 6.2 and 6.3.6.1.2 The impact testing shall be conducted at a room temperature of 77F (25C) or less within 5minutes of their removal from the conditioning temperat
14、ure, in accordance with the method described inthe Standard Test Method for Determination of the Impact Resistance of Thermoplastic Pipe and Fittingsby Means of a Tup (Falling Weight), ASTM D2444.6.2 Impact with flat Tup6.2.1 Representative pipe and fitting assemblies for each impact value in the mi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT1821A2005OUTLINEOFINVESTIGATIONFORTHERMOPLASTICSPRINKLERPIPEANDFITTINGSFORLOWPRESSUREDRYPIPEAPPLICATIONSISSUE1

链接地址:http://www.mydoc123.com/p-1069197.html