《UL SUBJECT 1783-1999 Outline of Investigation for Direct Connect Systems for Solid Fuel Burning Appliances (Issue 3)《固体燃料燃烧器用直接连接系统的调查纲要版本号 3》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 1783-1999 Outline of Investigation for Direct Connect Systems for Solid Fuel Burning Appliances (Issue 3)《固体燃料燃烧器用直接连接系统的调查纲要版本号 3》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、 STD-UL SUBJECT L783-ENGL 1999 9 7275795 077b07 BOT April 5, 1999 1 Subject 1783 OUTLINE OF INVESTIGATION FOR DIRECT CONNECT SYSTEMS FOR SOLID FUEL BURNING APPLIANCES Issue Number 3 April 5, 1999 COPYRIGHT O 1986.1999 UNDERWRITERS LABORATORIES INC. _ _ _ STD-UL SUBJECT 1783-ENGL 1777 7275775 077b708
2、 7ib D 2 SUBJECT 1783 APRIL 5,1999 No Text on This Page STD-UL SUBJECT 1783-ENGL 1777 D 7275775 077b707 b82 APRIL 5. 1999 SUBJECT 1783 3 CONTENTS FOREWORD 4 INTRODUCTION 1 Scope . 5 2 General 5 2.1 Terminology . 5 2.2 Units of measurement . 5 2.3 Components . 5 3 Glossary . 5 4 Installation and Main
3、tenance Instructions 6 4.1 General . 6 4.2 Installation instructions 6 4.3 Maintenance instructions 7 4.4 Coal burning accessory . 7 5 Materials . 8 6 Assembly 8 6.1 General . 8 6.2 Connection to flue collar . 9 6.3 Direct connection system flue-gas conduit . 9 6.4 Flue damper . 9 6.5 Radiation shie
4、ld and baffle . 9 PERFORMANCE 7 General 9 8 Temperature Measurement . 12 9 Thermal Shock Test and Preconditioning Exposure 13 1 O Temperature - 1000F (538C) Flue Gases 15 11 Temperature Test - 1400F (760C) Flue Gases . 15 12 Temperature Test - 21 00F (1 149C) Flue Gases 15 13 Strength Test . 16 14 S
5、weep Test 16 15 Flexibility Test for Flexible Direct Connect Systems . 17 16 Torsion Test for Flexible Direct Connect Systems . 17 17 Corrosion Resistance Test . 17 MARKING 18 General 20 STD=UL SUBJECT 1783-ENGL 1777 m 7275775 077b910 3TLI 4 SUBJECT 1783 APRIL 5, 1999 FOREWORD A. This Outline of Inv
6、estigation contains basic requirements for products covered by Underwriters Laboratories Inc. (UL) under its Follow-Up Service for this category within the limitations given below and in the Scope section of this Outline of Investigation. They are subject to revision as further experience and invest
7、igation may show is necessary or desirable. B. The observance of these requirements by a manufacturer is one of the conditions of the continued coverage of the manufacturers product. C. A product which complies with the text of this Outline of Investigation will not necessarily be judged to comply w
8、ith the Outline of Investigation if, when examined and tested, it is found to have other features which impair the level of safety contemplated by these requirements. D. A product employing materials or having forms of construction which conflict with specific requirements of the Outline of Investig
9、ation cannot be judged to comply with the Outline of Investigation. A product employing materials or having forms of construction not addressed by this Outline of Investigation may be examined and tested according to the intent of the requirements and, if found to meet the intent of this Outline of
10、Investigation, may be judged to comply with the Outline of Investigation. E. UL, in performing its functions in accordance with its objectives, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. The opinions and findings of UL represent its professio
11、nal judgement given with due consideration to the necessary limitations of practical operation and state of the art at the time the Outline of Investigation is processed. UL shall not be responsible to anyone for the use of or reliance upon this Outline of Investigation by anyone. UL shall not incur
12、 any obligation or liability for damages, including consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon this Outline of Investigation. F. Many tests required by the Outline of Investigations of UL are inherently hazardous and adequate safeguards f
13、or personnel and property shall be employed in conducting such tests. STD-UL SUBJECT 1783-ENGL 1779 7275775 077b91L 230 D APRIL 5, 1999 SUBJECT 1783 5 INTRODUCTION 1 Scope 1.1 These requirements cover direct connect systems that are intended to provide for direct connection between a solid-fuel burn
14、ing appliance and a masonry fireplace chimney. Solid-fuel burning appliances include fireplace stoves, room heaters, and fireplace inserts. Direct connect systems are intended for installation in accordance with the Standard for Chimneys, Fireplaces, Vents and Solid-Fuel Burning Appliances, NFPA 21
15、1. 2 General 2.1 Terminology 2.1.1 The term “product“ as used in these requirements refers to an entire direct connect system or any part thereof covered by these requirements unless specifically noted otherwise. 2.2 Units of measurement 2.2.1 If a value for measurement is followed by a value in oth
16、er units in parentheses, the second value may be only approximate. The first stated value is the requirement. 2.3 Components 2.3.1 Except as indicated in 2.3.2, a component of a product covered by this standard shall comply with the requirements for that component. 2.3.2 A component need not comply
17、with a specific requirement that: a) Involves a feature or characteristic not needed in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.3.3 A component shall be used in accordance with its recognized rating establishe
18、d for the intended conditions of use. 2.3.4 Specific components are recognized as being incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specified limits, and
19、shall be used only under those specific conditions for which they have been recognized. 3 Glossary 3.1 DIRECT CONNECTION - The type of flue connection required between a solid-fuel burning appliance and a masonry fireplace chimney, wherein a connector pipe extends from the appliance flue collar at l
20、east to the chimney flue liner. The connector pipe may or may not be attached to the chimney flue liner. 6 SUBJECT 1783 APRIL 5, 1999 4 Installation and Maintenance Instructions 4.1 General 4.1.1 The installation and maintenance instructions may be either in a single manual or be separate manuals, a
21、nd shall be packed with the product. 4.1.2 The instructions shall make reference to the manufacturers or private labelers catalog designation, or equivalent, for the product and/or its components, and shall include the manufacturers or private labelers name and address. 4.1.3 The installation and ma
22、intenance instructions required to be provided with the product shall be furnished with the sample submitted for investigation and shall be used as a guide in the investigation of the product. The instructions need not be in final printed form for the investigation. 4.2 Installation instructions 4.2
23、.1 Installation instructions shall be illustrated and include directions and information necessary to complete the intended installation of the product. 4.2.2 The installation instructions shall include: a) Details concerning the parts and materials required and the step-by-step process for installi
24、ng the product. b) Specific reference to indicate the type of appliance(s) and fuels with which the product is designed to be used. c) Instructions to the installer to examine the masonry fireplace and chimney prior to installation of the product to determine that the construction meets the minimum
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT17831999OUTLINEOFINVESTIGATIONFORDIRECTCONNECTSYSTEMSFORSOLIDFUELBURNINGAPPLIANCESISSUE3 固体燃料

链接地址:http://www.mydoc123.com/p-1069193.html