UL 60947-7-1 (ND)-2011 National Differences For UL 60947-7-1 Low-voltage switchgear and controlgear - Part 7-1 Ancillary equipment - Terminal blocks for copper conductors (Third Ed.pdf
《UL 60947-7-1 (ND)-2011 National Differences For UL 60947-7-1 Low-voltage switchgear and controlgear - Part 7-1 Ancillary equipment - Terminal blocks for copper conductors (Third Ed.pdf》由会员分享,可在线阅读,更多相关《UL 60947-7-1 (ND)-2011 National Differences For UL 60947-7-1 Low-voltage switchgear and controlgear - Part 7-1 Ancillary equipment - Terminal blocks for copper conductors (Third Ed.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60947-7-1Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks forcopper conductorsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER
2、 REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60947-7-1Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copperconductorsEdition: 3Edition Date: May 6, 2011This revision of ANSI/UL 60947-7-1 is to add the ANSI approval da
3、te to the title page. Thisstandard is a bi-national IEC-based standard that is harmonized for Mexico and the UnitedStates, and co-published by both standards development organizations (ANCE and UL).This document provides a single listing of the National Differences included in the UL adoption ofthe
4、corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this standards document as is wi
5、thout warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, lo
6、ss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs liability for any damage ever exceed the pricepaid for this standards docu
7、ment, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or deviation
8、introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright Underwriters Laboratories Inc.OCTOBER 14, 2011NATIONAL DIFFERENCES FOR UL UL 60947-7-12UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPref
9、aceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify national difference type, andthese types are additionally noted in this document
10、. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of products.D2 - These are deviations based on safety practices. These are deviation
11、s for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and will not be deleted until a particularcomponent standard is harmonized with the IEC
12、 component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what the national difference entails. Typically one of thefollowing words is used to exp
13、lain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table,figure, or annex. Addition is not meant to include adding select words to the base IEC text.Deletion / Delete - A deletion en
14、tails complete deletion of an entire numbered clause, subclause,table, figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as theaddition, replacement or deletion of certain words or the replacement of an entire claus
15、e,subclause, table, figure, or annex of the base IEC text.OCTOBER 14, 2011 NATIONAL DIFFERENCES FOR UL UL 60947-7-1 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational DifferencesDV.5 DC Modification to Standard Title:Change title to inc
16、lude “Terminal blocks for copper and aluminim conductors”.1.1DV.1 D2 Modification by adding the following:1.1DV.1.1 This standard also applies to terminal blocks that have insulation piercing ordisplacement clamping units.1.1DV.1.2 The wire range for terminal blocks covered by this standard include
17、0,051 mm2to 1 1010 mm2(30 AWG to 2 000 kcmil) copper conductors and 3,31 mm2to 1 010 mm2(12AWG to 2 000 kcmil) aluminum conductors. See Annex DVA for aluminum requirements.In Mexico, 3,31 mm2(12 AWG), 5,26 mm2(10 AWG), and 8,37 mm2(8 AWG) aluminumconductors are not allowed.1.1DV.1.3 The voltage rang
18、e includes up to 1 500 V ac and 1 500 V dc.1.1DV.2 DC Modification (Applicable for the United States):These requirements do not cover field installed power distribution blocks intended todistribute power in a building to separate units such as apartments, separate heaters, andair conditioning units.
19、 Power distribution blocks are investigated in accordance with theOutline of Investigation for Power Distribution Blocks, Subject 1953.1.2DV D1 Addition:See Annex DVB for standard references.2.5DV D2 Addition of the following definitions:2.5DV.1 printed circuit board (PCB) terminal block: a one-piec
20、e, or modular, or two-pieceterminal block fixed to a printed circuit board by soldering or other suitable means.2.5DV.2 special preparation (of conductor end): alteration of the manufactured shape orsurface of the conductor to enable it to be connected to the terminal.2.5DV.3 factory wiring terminal
21、: a terminal intended in the end application to beconnected under controlled conditions, usually at a manufacturers location. Suchterminations use prepared or unprepared conductors. Applicable for the United States. InMexico, this definition does not apply.2.5DV.4 insulation piercing or displacement
22、 clamping unit: a clamping unit for theconnection and possible disconnection of one conductor or the interconnection of twoor more conductors, the connection being made by piercing, boring through, cuttingthrough, removing, displacing, or making ineffective in some other manner the insulationof the
23、conductor or conductors without previous stripping.OCTOBER 14, 2011NATIONAL DIFFERENCES FOR UL UL 60947-7-14UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL2.5DV.5 post connector: a connector utilizing a post onto which one or more conductorsa
24、re secured by means of a tool.2.5DV.6 stud-and-nut type connector: a connector in which a conductor can be loopedaround a stud and retained by a nut or a connector that can retain a conductor that isfirst terminated in a wire connector.3DV D2 Modification by adding the following to the list of types
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL6094771ND2011NATIONALDIFFERENCESFORUL6094771LOWVOLTAGESWITCHGEARANDCONTROLGEARPART71ANCILLARYEQUIPMENTTERMINALBLOCKSFORCOPPERCONDUCTORSTHIRDEDPDF

链接地址:http://www.mydoc123.com/p-1068602.html