UL 2017 CRD-2016 UL Standard for Safety General-Purpose Signaling Devices and Systems - Section Paragraph Reference 37 37 1 Subject Revision to Require Leakage Current Test Only .pdf
《UL 2017 CRD-2016 UL Standard for Safety General-Purpose Signaling Devices and Systems - Section Paragraph Reference 37 37 1 Subject Revision to Require Leakage Current Test Only .pdf》由会员分享,可在线阅读,更多相关《UL 2017 CRD-2016 UL Standard for Safety General-Purpose Signaling Devices and Systems - Section Paragraph Reference 37 37 1 Subject Revision to Require Leakage Current Test Only .pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): UEHX, UDTZ, QVAX, UDGJ, UXPL, FSZI, FSYEStandard Number: UL 2017Standard Title: Standard for General-Purpose Signaling Devices and SystemsEdition Date: Decem
3、ber 23, 2008Edition Number: 2Section / Paragraph Reference: 37 / 37.1Subject: Revision to Require Leakage Current Test Only For Cord-connectedProducts.DECISION:37 Leakage Current Test37.1 When the Where a cord-connected product is powered by a source greater than 42.4 V peak, theleakage current at a
4、ny exposed surface, or between any accessible part and earth ground, or any otheraccessible part with an open circuit potential of is greater than 42.4 volts peak as measured between anyaccessible part and earth ground or any other accessible part, the leakage current at any accessible partshall not
5、 be more than the following values when tested in accordance with 37.2 - 37.7:a) 0.5 milliampere for an ungrounded (2-wire) portable, stationary, or fixed product;b) 0.5 milliampere for a grounded (3-wire) portable product; andc) 0.75 milliampere for a grounded (3-wire) stationary or fixed product.E
6、xception: When an electromagnetic radiation suppression filter is required for the product to function asintended, the leakage current shall not be more than 2.5 milliamperes, when the product complies withthe following conditions:a) The product shall be provided with grounding means in accordance w
7、ith the applicablerequirements for a cord-connected product in Grounding for Products Containing High-VoltageCircuits, Section 24;b) With the filter removed from the product, the leakage current shall not exceed the limitsspecified in 37.1 (b) and (c); as applicable, andc) The product is marked in a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL2017CRD2016ULSTANDARDFORSAFETYGENERALPURPOSESIGNALINGDEVICESANDSYSTEMSSECTIONPARAGRAPHREFERENCE37371SUBJECTREVISIONTOREQUIRELEAKAGECURRENTTESTONLYPDF

链接地址:http://www.mydoc123.com/p-1067770.html