SAE MAP 4296-1993 Drawing Interpretations Standard Machining Practice Tube Fittings and Connectors Fluid Systems Metric《图纸注释 标准机器操作 管配件和连接件 液压系统 米制》.pdf
《SAE MAP 4296-1993 Drawing Interpretations Standard Machining Practice Tube Fittings and Connectors Fluid Systems Metric《图纸注释 标准机器操作 管配件和连接件 液压系统 米制》.pdf》由会员分享,可在线阅读,更多相关《SAE MAP 4296-1993 Drawing Interpretations Standard Machining Practice Tube Fittings and Connectors Fluid Systems Metric《图纸注释 标准机器操作 管配件和连接件 液压系统 米制》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2015 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/MAP4296 AEROSPACE RECOMMENDED PRACTICEMAP4296 Issued 1993-06 Reaffirmed 2015-08 D
5、rawing Interpretations, Standard Machining Practice, Tube Fittings and Connectors, Fluid Systems, Metric RATIONALE MAP4296 has been reaffirmed to comply with the SAE five-year review policy. 1. SCOPE:This SAE Metric Aerospace Recommended Practice (MAP) establishes the drawing interpretations,standar
6、d machining practice for tube fittings and connectors used in metric fluid systems.1.1 Product Classification: This MAP is intended to interpret and clarify engineering drawing requirements relating to the manufacture and inspection of fluid tube fittings and connectors. Because it is impractical to
7、 define every minute detail of the part on the face of the drawing, this document describes general machining tolerances that fall under the heading of, “good shop practice“. This document serves as a supplement to engineering drawings when referenced on applicable documents.2. REFERENCES:2.1 Applic
8、able Documents: The following publications form a part of this specification to the extent specified herein. The latest issue of all SAE Technical Reports shall apply.2.1.1 ANSI/ASME Publications: Available from the American Society of Mechanical Engineers, 345 East 47th Street, New York, NY 10019.A
9、NSI/ASME B46.1 Surface TextureANSI Y14.5M Dimensioning and Tolerancing3. TECHNICAL REQUIREMENTS:3.1 General: 3.1.1 Conflict in Requirements: Where a conflict exists between the requirements of this document and the applicable part drawing, the part drawing shall take precedence.SAE INTERNATIONAL MAP
10、4296 Page 2 of 7 3.1.2 Burrs and Sharp Edges: Finished parts are to have all burrs and slivers removed. Break edges 0.08 to 0.38 mm unless otherwise noted.3.1.3 Dimensioning and Tolerancing: The rules, principles and methods of dimensioning and tolerancing used to define the required configuration a
11、re contained in ANSI Y14.5M.3.1.4 Titanium: When machining and cleaning titanium or titanium alloys, cutting fluids and compounds must not contain chlorides or fluorides.3.2 Tolerances: 3.2.1 Concentricity: See 3.2.5.3.2.2 Angularity: 3.2.2.1 Shapes: Angularity between the legs of shape fittings suc
12、h as tees, elbows, and crosses shall be as shown in Figure 1.FIGURE 1 - Angularity Tolerance Between Legs of Shape Fittings3.2.3 Drilled Holes: 3.2.3.1 Tolerance: For drilled holes without a specified size limit, the tolerances noted in Table 1 shall apply.SAE INTERNATIONAL MAP4296 Page 3 of 7 TABLE
13、 1 - Hole Size Tolerance3.2.3.2 Pilot Drill Size and Depth: The pilot drill size for a reamed or bored hole is generally not specified on the engineering drawing. Unless otherwise noted, the drilled hole may be smaller than the finished machined hole by not more than 0.8 mm. The depth of the reamed
14、or bored hole shall be within 0.8 mm of the drilled hole depth. See Figure 2.FIGURE 2 - Pilot Hole Size and Depth3.2.3.3 Drill Point: For conventional twist drills, the drill point included angle shall be 90 minimum.3.2.3.4 Runout: The angular runout from true center for fluid passage holes shall be
15、 as shown in Figures 3 and 4. The allowable drill runout is in addition to the angle tolerance specified on the drawing.FIGURE 3 - Fluid Passage Hole Runout of Shape FittingsSAE INTERNATIONAL MAP4296 Page 4 of 7 FIGURE 4 - Fluid Passage Runout of Straight Fittings3.2.4 Perpendicularity: Unless other
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEMAP42961993DRAWINGINTERPRETATIONSSTANDARDMACHININGPRACTICETUBEFITTINGSANDCONNECTORSFLUIDSYSTEMSMETRIC

链接地址:http://www.mydoc123.com/p-1028188.html