SAE AIR 4782A-2008 Hydrant Valve and Coupler Historical Background《消防龙头阀和耦合器的历史背景》.pdf
《SAE AIR 4782A-2008 Hydrant Valve and Coupler Historical Background《消防龙头阀和耦合器的历史背景》.pdf》由会员分享,可在线阅读,更多相关《SAE AIR 4782A-2008 Hydrant Valve and Coupler Historical Background《消防龙头阀和耦合器的历史背景》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2008 SAE International All rights reserved. No part of this publication ma
3、y be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA)
4、Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgAIR4782A AEROSPACEINFORMATIONREPORTIssued 1994-02 Revised 2008-08 Superseding AIR4782 Hydrant Valve and Coupler Historical Background RATIONALEThis revision adds websites to some of the reference documents. 1. SCOPE Th
5、is SAE Aerospace Information Report (AIR) presents historical information and background data related to hydrant valves and couplers used in worldwide ground refueling of commercial aircraft (hereafter generically referred to as hydrant devices). Military hydrant devices are not included since their
6、 mission requirements demand approaches that may differ.1.1 Purpose The purpose of this document is to provide definitions, background and educational information for use by design engineers, users of the systems and other interested parties who are involved with hydrant devices and associated equip
7、ment.1.2 Field of Application Soon after World War II, the military techniques for underwing refueling of turbine-engined aircraft were adopted for use on commercial aircraft. Advantages include significantly improved safety, convenience and rapidity of refueling. Refueling systems for commercial ai
8、rcraft evolved to comprise five basic elements, as follows: a. Hydrant systems (or supply systems) b. Hydrant couplers (hydrant system to servicer systems) c. Servicer system (hydrant to aircraft) d. Aircraft couplings (service systems to aircraft fuel systems) e. Aircraft fuel systems Element (d),
9、the aircraft couplings, are now true worldwide standards, having been adopted for military and commercial aircraft of all countries, and controlled by international standard documents. SAE AIR4782A - 2 -This document applies to the hydrant valve portions element (a), the entire element (b) and appli
10、cable portions of element (c). Some references to other elements are included, where pertinent. 2. APPLICABLE DOCUMENTS The following publications form a part of this document to the extent specified herein. The latest issue of SAE publications shall apply. The applicable issue of other publications
11、 shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exempti
12、on has been obtained. 2.1 API Publications Available from American Petroleum Institute, 1220 L Street, NW, Washington, DC 20005-4070, Tel: 202-682-8000, http:/api-ec.api.org.API Bulletin 1584API Standard for Four Inch Hydrant Systems Components and Arrangements 2.2 IP Publications Available from Lib
13、rary and Information Department, The Institute of Petroleum, 61 New Cavendish Street, London W1M 8AR, England, FAX 71 255 1472. No Number Aviation Hydrant Pit Systems - Recommended Arrangements for - Part I New Facilities, Part II Replacement of Obsolete Valves in Small Pit Boxes - August, 1990 2.3
14、Military Publications Available from the Document Automation and Production Service (DAPS), Building 4/D, 700 Robbins Avenue, Philadelphia, PA 19111-5094, Tel: 215-697-6257, http:/assist.daps.dla.mil/quicksearch/.MS24484 Adapter, Pressure Fuel Servicing, Nominal 2.5-inch Diameter MS29514 Flange, Ada
15、pter Locking, Pressure Fuel Servicing 2.4 ANSI Publications Available from ANSI, 25 West 43rd Street, New York, NY 10036-8002, Tel: 212-642-4900, www.ansi.org.ANSI B16.5 Pipe Flanges & Flanged Fittings 2.5 ISO Publications Available from American National Standards Institute, 25 West 43rd Street, Ne
16、w York, NY 10036-8002, Tel: 212-642-4900, www.ansi.org or from International Organization for Standardization, 1, rue de Varembe, Case postale 56, CH-1211 Geneva 20, Switzerland, Tel: +41-22-749-01-11, www.iso.org.ISO/DIS 45:1990 Aircraft Pressure Refueling Connections 2.6 Definitions AIRCRAFT REFUE
17、LING ADAPTER: A part of the aircraft fuel system, it is the mating portion of the quick disconnect by which the Hydrant Servicer (Nozzle) is connected to the aircraft. This connection is dimensionally in accordance with MS24484, MS29514, ISO 45, and NATO STANAG 3105. The latter two documents are int
18、ernational standards to assure interchangeability.SAE AIR4782A - 3 -DEADMAN CONTROL: The manual capability of open-close control of flow through the Hydrant System and Hydrant Servicer by an operator. This feature requires the operator to hold a switch or valve in a predetermined position to keep fl
19、ow through the system. The valve, being held by the operator, normally controls the application of an air reference pressure to the Deadman Control Valve. The switch may control a solenoid valve that releases the application of air pressure to the Deadman Control Valve. Release of the switch or valv
20、e will automatically stop flow. EXCESS-FLOW CONTROL: Some Hydrant Valves or Hydrant Couplers include a feature that will automatically stop flow through the system if the flow rate exceeds a predetermined value. Some such units have the capability of having two such settings, high and low settings,
21、to accommodate aircraft of different capacity. This is intended to prevent a major spill of fuel in case of an intake hose rupture and is sometimes used to supplement other emergency shut down devices such as deadman and lanyard operated controls. HOSE END CONTROL VALVE OR REGULATOR: A direct acting
22、 pressure control device that is mounted as an integral part of the Underwing Nozzle. HYDRANT COUPLER: The mechanical quick connection between the Hydrant Servicer and the Hydrant Valve. The Hydrant Coupler may include various control features or may be a simple quick coupling. HYDRANT PIT: A covere
23、d small chamber containing the hydrant system pipe terminus, hydrant valve, and associated equipment. The pit is strategically located to provide access to the aircraft underwing Refueling Adapter. HYDRANT SERVICER: Also called Hydrant Cart or Hydrant Dispenser. A vehicle, self-propelled or towable,
24、 that contains the necessary equipment to allow for connection to the Hydrant Valve and the aircraft refueling adapter. The Hydrant Servicer may include, but not be limited to, intake hose, outlet hoses, booster pumps, meters, filter separators or monitors, pressure control systems, and other equipm
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAIR4782A2008HYDRANTVALVEANDCOUPLERHISTORICALBACKGROUND 消防 龙头 耦合器 历史背景 PDF

链接地址:http://www.mydoc123.com/p-1020188.html