《NFPA 96-2017 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations (Effective Date 12 01 2016).pdf》由会员分享,可在线阅读,更多相关《NFPA 96-2017 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations (Effective Date 12 01 2016).pdf(71页珍藏版)》请在麦多课文档分享上搜索。
1、 NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations 2017IMPORTANT NOTICES AND DISCLAIMERS CONCERNING NFPA STANDARDS NOTICE AND DISCLAIMER OF LIABILITY CONCERNING THE USE OF NFPA STANDARDS NFPA codes, standards, recommended practices, and guides (“NFPA Stand
2、ards”), of which the document contained herein is one, are developed through a consensus standards development process approved by the American National Standards Institute. This process brings together volunteers representing varied viewpoints and interests to achieve consensus on re and other safe
3、ty issues. While the NFPA administers the process and establishes rules to promote fairness in the development of consensus, it does not independently test, evaluate, or verify the accuracy of any information or the soundness of any judgments contained in NFPA Standards. The NFPA disclaims liability
4、 for any personal injury, property or other damages of any nature whatsoever, whether special, indirect, consequential or compensatory, directly or indirectly resulting from the publication, use of, or reliance on NFPA Standards. The NFPA also makes no guaranty or warranty as to the accuracy or comp
5、leteness of any information published herein. In issuing and making NFPA Standards available, the NFPA is not undertaking to render professional or other services for or on behalf of any person or entity. Nor is the NFPA undertaking to perform any duty owed by any person or entity to someone else. A
6、nyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. The NFPA has no power, nor does it undertake, to police or enforce compliance with t
7、he contents of NFPA Standards. Nor does the NFPA list, certify, test, or inspect products, designs, or installations for compliance with this document. Any certication or other statement of compliance with the requirements of this document shall not be attributable to the NFPA and is solely the resp
8、onsibility of the certier or maker of the statement. REMINDER: UPDATING OF NFPA STANDARDS Users of NFPA codes, standards, recommended practices, and guides (“NFPA Standards”) should be aware that NFPA Standards may be amended from time to time through the issuance of Tentative Interim Amendments or
9、corrected by Errata. An ofcial NFPA Standard at any point in time consists of the current edition of the document together with any Tentative Interim Amendment and any Errata then in effect. In order to determine whether an NFPA Standard has been amended through the issuance of Tentative Interim Ame
10、ndments or corrected by Errata, visit the “Codes email: stds_adminnfpa.org. For more information about NFPA, visit the NFPA website at www.nfpa.org. All NFPA codes and standards can be viewed at no cost at www.nfpa.org/docinfo.96-1 NFPA and National Fire Protection Association are registered tradema
11、rks of the National Fire Protection Association, Quincy, Massachusetts 02169. Copyright 2016 National Fire Protection Association . All Rights Reserved. NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations 2017 Edition This edition of NFPA 96, Standard for Ve
12、ntilation Control and Fire Protection of Commercial Cooking Operations, was prepared by the Technical Committee on Venting Systems for Cooking Appliances. It was issued by the Standards Council on November 11, 2016, with an effective date of December 1, 2016, and supersedes all previous editions. Th
13、is edition of NFPA 96 was approved as an American National Standard on December 1, 2016. Origin and Development of NFPA 96 The subject of the ventilation of restaurant-type cooking equipment was rst considered by the NFPA Committee on Blower and Exhaust Systems, which developed material on ventilati
14、on of restaurant-type cooking equipment to be included in NFPA 91, Standard for the Installation of Blower and Exhaust Systems for Dust, Stock, and Vapor Removal or Conveying. That standard was adopted by the Association in 1946, and revisions were adopted in 1947 and 1949. When the NFPA Committee o
15、n Chimneys and Heating Equipment was organized in 1955, the material on ventilation of restaurant cooking equipment in NFPA 91 was assigned to the new committee with the suggestion that it be revised and published as a separate standard. Since then, the standard has been published as NFPA 96. Editio
16、ns prepared by the Committee on Chimneys and Heating Equipment were adopted by the Association in 1961, 1964, 1969, 1970, 1971, 1973, 1976, 1978, 1980, and 1984. The Correlating Committee on Chimneys and Other Heat and Vapor Removal Equipment was discharged by the Standards Council in 1986. The Tech
17、nical Committee that prepared the 1987 edition of NFPA 96 became known as the Technical Committee on Venting Systems for Cooking Appliances. In the 1991 edition, clearance requirements to combustible material were revised and expanded, including appendix gures that illustrated examples. A new deniti
18、on for limited-combustible was added to the standard, and an appendix table was included to show typical construction assemblies. Chapters 3 and 4 were totally revised. In the 1994 edition, the Committee changed the name of the standard from Standard for the Installation of Equipment for the Removal
19、 of Smoke and Grease-Laden Vapors from Commercial Cooking Equipment to Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations. The title change reected other changes in the standard: two new chapters, one on recirculating systems and the other on solid fuel cooking ope
20、rations, were added. A change to clearance and enclosure requirements in the 1994 edition allowed, for the rst time, materials or products to be directly applied to a duct. The Committee prepared a revision to the standard reporting to the 1996 Fall Meeting, which was returned to the Committee at th
21、e Technical Committee Reports Session. The 1998 edition contained new denitions, minor revisions throughout, and a completely revised Chapter 7 on re-extinguishing equipment. The 2001 edition revised the document scope to clarify the application of the standard regarding residential-type cooking equ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NFPA962017STANDARDFORVENTILATIONCONTROLANDFIREPROTECTIONOFCOMMERCIALCOOKINGOPERATIONSEFFECTIVEDATE12012016PDF

链接地址:http://www.mydoc123.com/p-1008878.html