NAVY UFGS-08 56 53-2011 BLAST RESISTANT TEMPERED GLASS WINDOWS《防爆钢化玻璃窗户》.pdf
《NAVY UFGS-08 56 53-2011 BLAST RESISTANT TEMPERED GLASS WINDOWS《防爆钢化玻璃窗户》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-08 56 53-2011 BLAST RESISTANT TEMPERED GLASS WINDOWS《防爆钢化玻璃窗户》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-08 56 53 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-08 56 53 (April 2006) UFGS-08581 (August 2001)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08
2、56 53BLAST RESISTANT TEMPERED GLASS WINDOWS08/11PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 QUALITY ASSURANCE1.3.1 Label1.3.2 Glass and Glazing1.3.3 Independent Testing1.4 DELIVERY, STORAGE, AND HANDLING1.5 ENVIRONMENTAL CONDITIONSPART 2 PRODUCTS2.1 WINDOW UNITS2.2 WEATHERSTRIPPING2.3 GLASS2.4 SET
3、TING MATERIALS2.4.1 Elastomeric Sealant2.4.2 Sealing Tapes, Beads or Gaskets2.4.3 Setting Blocks and Edge Blocks2.4.4 Accessories2.5 WINDOW ASSEMBLIES2.5.1 Provisions for Glazing2.5.2 Sealant, Gaskets, and Beads2.5.3 Weatherstripping2.5.4 Fasteners2.5.5 Drips and Weep Holes2.5.6 Combination Windows2
4、.5.7 Accessories2.5.8 Hardware2.5.9 Anchors2.5.10 Window Cleaner Anchors2.5.11 Finishes2.5.11.1 Anodic Coating2.5.11.2 Organic CoatingSECTION 08 56 53 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.6 SOURCE QUALITY CONTROL2.6.1 Window Assemb
5、ly Structural Test2.6.1.1 Test Sample Number2.6.1.2 Test Procedure2.6.1.3 Acceptance CriteriaPART 3 EXECUTION3.1 INSTALLATION3.1.1 Method of Installation3.1.2 Glass Setting3.1.3 Dissimilar Materials3.1.4 Anchors and Fastenings3.1.5 Adjustments After Installation3.2 CLEANING3.3 SCHEDULE- End of Secti
6、on Table of Contents -SECTION 08 56 53 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-08 56 53 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-08 56 53 (April 2006) UFGS-08581 (August 2001)UNIFIED
7、FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION 08 56 53BLAST RESISTANT TEMPERED GLASS WINDOWS08/11*NOTE: This guide specification covers the requirements for blast resistant tempered glass windows.Adhere to UFC 1-300-02 Unified Facilities Guide Specifica
8、tions (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information
9、.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: Specific details are expanded upon in
10、MIL-HBK-1013/1, Design Guidelines for Physical Security of Fixed Land-Based Facilities.*NOTE: TO DOWNLOAD UFGS GRAPHICSGo to http:/www.wbdg.org/ccb/NAVGRAPH/graphtoc.pdf.*NOTE: On the drawings, show:1. Locations of each type of glass, using same terminology as in the specification.SECTION 08 56 53 P
11、age 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2. Frame and rabbet details, indicating method of glazing.3. Sizes and types of windows; metal and wood subframes, casings, or stools, if any; and hardware.4. Sizes, location, and swing of ventilat
12、ors; direction of slide for sliding ventilators; location and details of fixed sash.5. Typical window sections and details. Show glass thickness. Show special glazing, if any.6. Method of anchoring windows; size and types of clips, anchors, screws, or other fasteners.7. Details of nonstructural mull
13、ions and mullion covers; detail of anchoring and reinforcing nonstructural mullions at windows to receive window cleaner anchors.8. Number of window cleaner anchors required and locations.9. Locations of windows designated as forced entry resistant, if any.*PART 1 GENERAL1.1 REFERENCES*NOTE: This pa
14、ragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RI
15、D outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification whe
16、n you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.SECTION 08 56 53 Page 4Provided by IHSNot for ResaleNo reproduct
17、ion or networking permitted without license from IHS-,-,-ALUMINUM ASSOCIATION (AA)AA DAF45 (2003; Reaffirmed 2009) Designation System for Aluminum FinishesAMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)AAMA 2603 (2002) Voluntary Specification, Performance Requirements and Test Procedures for
18、 Pigmented Organic Coatings on Aluminum Extrusions and PanelsAAMA 2604 (2005) Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and PanelsAAMA/WDMA/CSA 101/I.S.2/A440 (2008; Update 1 2008; Update 2 2008; Update 3 2009)
19、North American Fenestration Standard/Specification for Windows, Doors, and SkylightsAMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)ANSI Z97.1 (2009; Errata 2010) Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of TestASTM INTERNATIONAL (ASTM)ASTM C1048 (2004)
20、Standard Specification for Heat-Treated Flat Glass - Kind HS, Kind FT Coated and Uncoated GlassASTM C509 (2006; R 2011) Elastomeric Cellular Preformed Gasket and Sealing MaterialASTM C920 (2011) Standard Specification for Elastomeric Joint SealantsGLASS ASSOCIATION OF NORTH AMERICA (GANA)GANA Glazin
21、g Manual (2004) Glazing Manual1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality contro
22、l.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors SECTION 08 56 53 Page 5Provided by IHSNot for Resa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0856532011BLASTRESISTANTTEMPEREDGLASSWINDOWS 防爆 钢化玻璃 窗户 PDF

链接地址:http://www.mydoc123.com/p-984749.html