1、*USACE / NAVFAC / AFCESA / NASA UFGS-08 52 00 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-08 52 00 (July 2006)UFGS-08550 (August 2001)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 52
2、 00WOOD WINDOWS08/11PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 DELIVERY AND STORAGE1.4 SUSTAINABLE DESIGN REQUIREMENTS1.4.1 Local/Regional Materials1.4.2 Environmental Data1.4.3 Forest Stewardship Council (FSC) Certification1.4.4 Plastic IdentificationPART 2 PRODUCTS2.1 MATERIALS2.1.1 Virgin Lumb
3、er2.1.2 Engineered Wood Products2.1.3 Metal Plastic _2.2 WOOD WINDOWS2.2.1 Single-Hung and Double-Hung Windows2.2.2 Awning Windows (Top Hinged)2.2.3 Casement Windows2.2.4 Horizontal-Sliding Windows2.2.5 Stationary Windows2.3 ACCESSORIES2.3.1 Adhesives2.3.2 Fasteners2.4 FINISHES2.4.1 Paint2.4.2 Vinyl
4、 (PVC) Cladding2.4.3 Aluminum Cladding2.4.3.1 Aluminum Finish2.4.3.2 Anodic Coating2.4.3.3 Organic Coating2.5 INSECT SCREENS2.6 STORM SASHSECTION 08 52 00 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.6.1 FinishesPART 3 EXECUTION3.1 INSTALL
5、ATION3.1.1 Wood and Wood Clad Windows3.1.2 Insect Screen3.1.3 Storm Windows3.2 ADJUSTMENTS3.3 CLEANING3.4 WASTE MANAGEMENT- End of Section Table of Contents -SECTION 08 52 00 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFC
6、ESA / NASA UFGS-08 52 00 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-08 52 00 (July 2006)UFGS-08550 (August 2001)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION 08 52 00WOOD WINDOWS08/11*NOTE: This guide specification covers the requi
7、rements for wood windows of the following types: single-hung, double-hung, awning, casement, horizontal sliding, and non-operative (stationary window unit).Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new pro
8、ject specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not
9、 brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. Th
10、e publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the R
11、eference Article. Also use the SECTION 08 52 00 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section
12、of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ALUMINUM ASSOCIATION (AA)AA DAF4
13、5 (2003; Reaffirmed 2009) Designation System for Aluminum FinishesAMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)AAMA 2603 (2002) Voluntary Specification, Performance Requirements and Test Procedures for Pigmented Organic Coatings on Aluminum Extrusions and PanelsAAMA 2604 (2005) Voluntary S
14、pecification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and PanelsAAMA/WDMA/CSA 101/I.S.2/A440 (2008; Update 1 2008; Update 2 2008; Update 3 2009) North American Fenestration Standard/Specification for Windows, Doors, and SkylightsASTM
15、INTERNATIONAL (ASTM)ASTM D 1784 (2011) Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) CompoundsASTM D 1972 (1997; R 2005) Standard Practice for Generic Marking of Plastic ProductsASTM D 3656 (2007) Insect Screening and Louver Cloth W
16、oven from Vinyl-Coated Glass YarnsASTM D 6007 (2002; R 2008) Standard Test Method for Determining Formaldehyde Concentration in Air from Wood Products Using a Small Scale ChamberASTM D 6330 (1998; R 2008) Standard Practice for Determination of Volatile Organic Compounds (Excluding Formaldehyde) Emis
17、sions from Wood-Based Panels Using Small Environmental Chambers Under Defined Test ConditionsSECTION 08 52 00 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ASTM E 1333 (2010) Determining Formaldehyde Concentrations in Air and Emission Rates f
18、rom Wood Products Using a Large ChamberASTM E 2129 (2005) Standard Practice for Data Collection for Sustainability Assessment of Building ProductsFOREST STEWARDSHIP COUNCIL (FSC)FSC STD 01 001 (2000) Principles and Criteria for Forest StewardshipGREEN SEAL (GS)GS-36 (2000) Commercial AdhesivesNATION
19、AL FENESTRATION RATING COUNCIL (NFRC)NFRC 100 (2010) Procedure for Determining Fenestration Product U-FactorsNFRC 200 (2010) Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal IncidenceSCREEN MANUFACTURERS ASSOCIATION (SMA)SMA 1004 (1987; R
20、 1998) Aluminum Tubular Frame Screens for WindowsSOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD)SCAQMD Rule 1168 (1989; R 2005) Adhesive and Sealant ApplicationsU.S. ENVIRONMENTAL PROTECTION AGENCY (EPA)Energy Star (1992; R 2006) Energy Star Energy Efficiency Labeling SystemU.S. GREEN BUILDING
21、COUNCIL (USGBC)LEED (2002; R 2005) Leadership in Energy and Environmental Design(tm) Green Building Rating System for New Construction (LEED-NC)WINDOW AND DOOR MANUFACTURERS ASSOCIATION (WDMA)WDMA I.S. 4 (2009) Water-Repellent Preservative Non-Pressure Treatment for Millwork1.2 SUBMITTALS*NOTE: Subm
22、ittals must be limited to those necessary SECTION 08 52 00 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-for adequate quality control. The importance of an item in the project should be one of the primary factors in determining if a submittal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0852002011WOODWINDOWS 木制 窗户 PDF