1、*USACE / NAVFAC / AFCESA UFGS-08 14 00 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-08 14 00 (May 2011)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 14 00WOOD DOORS08/11PART 1 GENERAL
2、1.1 REFERENCES1.2 SUBMITTALS1.3 SUSTAINABLE DESIGN CERTIFICATION/DOCUMENTATION1.4 LOCAL/REGIONAL MATERIALS1.5 DELIVERY, STORAGE, AND HANDLING1.6 WARRANTYPART 2 PRODUCTS2.1 DOORS2.1.1 Stile and Rail Doors2.1.2 Flush Doors2.1.2.1 Exterior Flush Doors2.1.2.2 Interior Flush Doors2.1.3 Bi-Fold Closet Doo
3、rs2.1.4 Sliding Closet Doors2.1.5 X-Ray Resistant Doors2.1.6 Acoustical Doors2.1.7 Composite-Type Fire Doors2.1.8 Prehung Doors2.2 ACCESSORIES2.2.1 Door Louvers2.2.2 Door Light Openings2.2.3 Weatherstripping2.2.4 Additional Hardware Reinforcement2.3 FABRICATION2.3.1 Marking2.3.2 Quality and Construc
4、tion2.3.3 Preservative Treatment2.3.4 Adhesives and Bonds2.3.5 Prefitting2.3.6 Finishes2.3.6.1 Field Painting2.3.6.2 Factory Finish2.3.6.3 Plastic Laminate FinishSECTION 08 14 00 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.3.6.4 Color2.3.
5、7 Water-Resistant Sealer2.4 SOURCE QUALITY CONTROLPART 3 EXECUTION3.1 INSTALLATION3.1.1 Fire and Smoke Doors3.1.2 Prehung Doors3.1.3 Weatherstripping3.2 SCHEDULE- End of Section Table of Contents -SECTION 08 14 00 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without lic
6、ense from IHS-,-,-*USACE / NAVFAC / AFCESA UFGS-08 14 00 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-08 14 00 (May 2011)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION 08 14 00WOOD DOORS08/11*NOTE: This guide specification covers requ
7、irements for wood doors.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text.
8、For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted
9、 as a Criteria Change Request (CCR).*NOTE: On the drawings, show:1. Locations2. Sizes, types, thicknesses, glazing, and louvers3. Designs4. Fire rating requirements5. Color6. Door swing7. Sound transmission class.*SECTION 08 14 00 Page 3Provided by IHSNot for ResaleNo reproduction or networking perm
10、itted without license from IHS-,-,-PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date,
11、and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text wil
12、l automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designat
13、ion only.ARCHITECTURAL WOODWORK INSTITUTE (AWI)AWI Qual Stds (8th Edition) AWI Quality StandardsASTM INTERNATIONAL (ASTM)ASTM E 283 (2004) Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the SpecimenASTM E 90 (2009) S
14、tandard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and ElementsASTM E2226 (2010; E 2011) Standard Practice for Application of Hose StreamGREENGUARD ENVIRONMENTAL INSTITUTE (GEI)GEI Greenguard Standards for Low Emitting ProductsNATIONAL ELECTRICA
15、L MANUFACTURERS ASSOCIATION (NEMA)ANSI/NEMA LD 3 (2005) Standard for High-Pressure Decorative LaminatesSECTION 08 14 00 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 105 (2010) Standard for Inst
16、allation of Smoke Door Assemblies and Other Opening ProtectivesNFPA 252 (2008) Standard Methods of Fire Tests of Door AssembliesNFPA 80 (2010; TIA 10-2) Standard for Fire Doors and Other Opening ProtectivesSCIENTIFIC CERTIFICATION SYSTEMS (SCS)SCS Scientific Certification Systems (SCS)Indoor Advanta
17、geU.S. GREEN BUILDING COUNCIL (USGBC)LEED (2002; R 2005) Leadership in Energy and Environmental Design(tm) Green Building Rating System for New Construction (LEED-NC)LEED Reference Guide (2005) LEED-NC Reference Guide for New ConstructionUNDERWRITERS LABORATORIES (UL)UL 10B (2008; Reprint Apr 2009)
18、Fire Tests of Door AssembliesWINDOW AND DOOR MANUFACTURERS ASSOCIATION (WDMA)WDMA I.S. 1-A (2007) Architectural Wood Flush DoorsWDMA I.S. 4 (2009) Water-Repellent Preservative Non-Pressure Treatment for MillworkWDMA I.S. 6 (2008) Wood Stile and Rail DoorsWDMA TM-7 (2008) Cycle Slam Test MethodWDMA T
19、M-8 (2008) Hinge Loading Test Method1.2 SUBMITTALS*NOTE: Where a “G“ in submittal tags follows a submittal item, it indicates Government approval for that item. Add “G“ in submittal tags following any added or existing submittal items deemed sufficiently critical, complex, or aesthetically significa
20、ntly to merit approval by the Government. Submittal items not designated with a “G“ will be approved by the QC organization.*Submit the following in accordance with Section 01 33 00 SUBMITTAL SECTION 08 14 00 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0814002011WOODDOORS 木制 PDF