NAVY UFGS-08 11 13-2010 STEEL DOORS AND FRAMES《钢制门和框架》.pdf
《NAVY UFGS-08 11 13-2010 STEEL DOORS AND FRAMES《钢制门和框架》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-08 11 13-2010 STEEL DOORS AND FRAMES《钢制门和框架》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA UFGS-08 11 13 (February 2010)-Preparing Activity: NAVFAC Superseding UFGS-08 11 13 (August 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2010*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 11 13STEEL DOORS AND FRAMES
2、02/10PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 DELIVERY, STORAGE, AND HANDLINGPART 2 PRODUCTS2.1 STANDARD STEEL DOORS2.1.1 Classification - Level, Performance, Model2.1.1.1 Standard Duty Doors2.1.1.2 Heavy Duty Doors2.1.1.3 Extra Heavy Duty Doors2.1.1.4 Maximum Duty Doors2.2 CUSTOM HOLLOW METAL
3、DOORS2.3 INSULATED STEEL DOOR SYSTEMS2.4 SOUND RATED STEEL DOORS2.5 ACCESSORIES2.5.1 Shelves for Dutch Doors2.5.2 Louvers2.5.2.1 Interior Louvers2.5.2.2 Exterior Louvers2.5.3 Astragals2.5.4 Moldings2.6 INSULATION CORES2.7 STANDARD STEEL FRAMES2.7.1 Welded Frames2.7.2 Knock-Down Frames2.7.3 Mullions
4、and Transom Bars2.7.4 Stops and Beads2.7.5 Terminated Stops2.7.6 Cased Openings2.7.7 Anchors2.7.7.1 Wall Anchors2.7.7.2 Floor Anchors2.8 FIRE AND SMOKE DOORS AND FRAMESSECTION 08 11 13 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.8.1 Label
5、s2.8.2 Oversized Doors2.8.3 Astragal on Fire and Smoke Doors2.9 WEATHERSTRIPPING2.9.1 Integral Gasket2.10 HARDWARE PREPARATION2.11 FINISHES2.11.1 Factory-Primed Finish2.11.2 Hot-Dip Zinc-Coated and Factory-Primed Finish2.11.3 Electrolytic Zinc-Coated Anchors and Accessories2.11.4 Factory-Applied Ena
6、mel Finish2.12 FABRICATION AND WORKMANSHIP2.12.1 Grouted Frames2.13 PROVISIONS FOR GLAZINGPART 3 EXECUTION3.1 INSTALLATION3.1.1 Frames3.1.2 Doors3.1.3 Fire and Smoke Doors and Frames3.2 PROTECTION3.3 CLEANING3.4 SCHEDULE- End of Section Table of Contents -SECTION 08 11 13 Page 2Provided by IHSNot fo
7、r ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA UFGS-08 11 13 (February 2010)-Preparing Activity: NAVFAC Superseding UFGS-08 11 13 (August 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2010*SECTION
8、08 11 13STEEL DOORS AND FRAMES02/10*NOTE: This guide specification covers steel doors and frames. Some paragraphs may need to be supplemented to meet project requirements.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choos
9、e applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestion on this specification are welcome and should be directed to the technical proponent of the specification. A list
10、ing of Technical Proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*NOTE: On the drawings, show:1. Sizes of door openings, thicknesses of doors, swings, and travels of doo
11、rs, and design of doors, whether flush panel, full flush, paneled, glazed, or louvered. It is recommended that standard door-type nomenclature, SDI 106, be used to indicate designs (e.g., F, L, G, GL, etc., in lieu of A, B, C, etc.).2. Details of nonstructural mullions, mullion covers, and removable
12、 mullions.3. Type and thickness of glazing required; whether or not insulating glass units are required.SECTION 08 11 13 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-4. Method, type, and spacing required for anchoring door frames to adjoinin
13、g construction.5. Lintels and reinforcement required to support walls or partitions above doors.6. Type of shop finish on steel surfaces.7. Free area for louvers in doors.8. Complete door schedule. Schedule should assign a separate number for each opening and should indicate door type and style, mat
14、erial, design, size, thickness, glazed or unglazed, class fire rating for fire doors, hardware set number, threshold material, if any, and material for frames, mullions, and transom bars.*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guid
15、e specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the
16、 reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The
17、 publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.AMERICAN WELDING SOCIETY (AWS)AWS D1.1/D1.1M (2008; Errata 2008) Structural Welding Code - SteelASTM INTERNATIONAL (ASTM)ASTM A 653/A 653M
18、 (2009a) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessSECTION 08 11 13 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ASTM A 879/A 879M (2006) Standard Specific
19、ation for Steel Sheet, zinc Coated by the Electrolytic Process for Applications Requiring Designation of the Coating Mass on Each SurfaceASTM A 924/A 924M (2009a) Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip ProcessASTM C 578 (2009e1) Standard Speci
20、fication for Rigid, Cellular Polystyrene Thermal InsulationASTM C 591 (2009) Standard Specification for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal InsulationASTM C 612 (2009) Mineral Fiber Block and Board Thermal InsulationASTM D 2863 (2009) Measuring the Minimum Oxygen Concentration
21、to Support Candle-Like Combustion of Plastics (Oxygen Index)ASTM E 1300 (2009a) Determining Load Resistance of Glass in BuildingsASTM E 283 (2004) Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the SpecimenASTM F 224
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0811132010STEELDOORSANDFRAMES 钢制 框架 PDF

链接地址:http://www.mydoc123.com/p-984732.html