1、*USACE / NAVFAC / AFCESA / NASA UFGS-07 14 00 (February 2012)-Preparing Activity: NAVFAC SupersedingUFGS-07 14 00 (April 2006)UFGS-07141 (December 2003)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2012*SECTION TABLE OF CONTENTSDIVISION 07 - THERMAL AND M
2、OISTURE PROTECTIONSECTION 07 14 00FLUID-APPLIED WATERPROOFING02/12PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 PREWATERPROOFING CONFERENCE1.4 DELIVERY, STORAGE, AND HANDLING1.5 ENVIRONMENTAL CONDITIONS1.6 WARRANTY1.6.1 Roof Membrane Manufacturer Warranty1.6.2 Roofing System Installer Warranty1.6.3
3、Continuance of WarrantyPART 2 PRODUCTS2.1 FLUID-APPLIED MEMBRANE2.2 MEMBRANE PRIMER2.3 SEALANT2.4 SEALANT PRIMER2.5 BACKING MATERIAL2.6 JOINT FILLER2.7 BOND BREAKER2.8 ELASTOMERIC SHEET2.9 ELASTOMERIC SHEET ADHESIVE2.10 FLEXIBLE FOAM-BACKED ELASTOMERIC SHEET2.11 PROTECTION BOARD2.12 DRAINAGE COURSE
4、AGGREGATE2.13 INSULATIONPART 3 EXECUTION3.1 PREPARATION3.1.1 Flashings3.1.1.1 Drains3.1.1.2 Penetrations and Projections3.1.1.3 Walls and Vertical SurfacesSECTION 07 14 00 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.1.2 Cracks and Joints3
5、.1.3 Priming3.2 SPECIAL PRECAUTIONS3.3 APPLICATION3.3.1 Work Sequence3.3.2 Protection Board3.3.3 Drainage Course3.3.4 Insulation3.4 FIELD QUALITY CONTROL3.4.1 Moisture Test3.4.2 Film Thickness3.4.3 Flood Test3.5 INSTRUCTIONS TO GOVERNMENT PERSONNEL3.6 INFORMATION CARD- End of Section Table of Conten
6、ts -SECTION 07 14 00 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-07 14 00 (February 2012)-Preparing Activity: NAVFAC SupersedingUFGS-07 14 00 (April 2006)UFGS-07141 (December 2003)UNIFIED FACILITIES GUID
7、E SPECIFICATIONSReferences are in agreement with UMRL dated January 2012*SECTION 07 14 00FLUID-APPLIED WATERPROOFING02/12*NOTE: This guide specification covers the requirements for fluid-applied elastomeric waterproofing systems for building decks over occupied space where membrane is protected of a
8、 separate wearing course.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text.
9、 For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitte
10、d as a Criteria Change Request (CCR).*NOTE: This guide specification should not be used to specify waterproofing of structures subject to hydrostatic pressure. It includes the fluid-applied membrane, protection board, drainage layer, and insulation. It does not include structural deck, protection sl
11、ab, or wearing course; these elements influence performance of the waterproofing system. See UFC 3-110-03, “Roofing“ for design recommendations.*Technical Reference: ASTM C898, “High Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane with Separate Wearing SECTION 07 14 00 Page 3P
12、rovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Course.“ This document contains guidelines for design of the waterproofing system, and may be used as a source of supplementary information.1. Slope: Provide slope toward drains (after deflections due to
13、 applied load and creep) of not less than one percent 10 mm per meter 1/8 inch per foot.2. Wall Flashing: Extend wall flashing to at least 100 mm 4 inches above wearing surface and higher where exposure is more severe. If top of flashing is recessed under a concrete wall, counterflashing is not nece
14、ssary. Metal counterflashing is necessary at masonry wall intersections. Flash right-angle intersection of deck and wall with an elastomeric sheet.*NOTE: This section contains both metric and inch-pound graphics.NUMBER TITLE1 Basic Components of Membrane with Separate Wearing Course2 Flashing at Cra
15、cks and Nonmoving Joints in the Concrete3 Expansion Joint Flashing4 Expansion Joint Flashing at Wall5 Terminal Condition with Masonry Above Finish Wearing Surfaceat Grade6 Wall Flashing on Concrete Wall7 Wall - Deck Flashing8 Penetration Flashing9 Drain FlashingDO NOT INCLUDE THE SKETCHES OR LIST OF
16、 SKETCHES IN THE PROJECT SPECIFICATIONS. USE SKETCHES FOR PREPARING DETAILS ON THE DRAWINGS.*NOTE: TO DOWNLOAD UFGS GRAPHICSGo to http:/www.wbdg.org/ccb/NAVGRAPH/graphtoc.pdf.*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specificat
17、ion. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.SECTION 07 14 00 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Use the Reference Wizards Ch
18、eck Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this s
19、ection of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ASTM INTERNATIONAL (ASTM)
20、ASTM C33/C33M (2011a) Standard Specification for Concrete AggregatesASTM C578 (2011a) Standard Specification for Rigid, Cellular Polystyrene Thermal InsulationASTM C836/C836M (2011a) High Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane for Use With Separate Wearing CourseASTM
21、D1056 (2007) Standard Specification for Flexible Cellular Materials - Sponge or Expanded RubberASTM D1751 (2004; R 2008) Standard Specification for Preformed Expansion Joint Filler for Concrete Paving and Structural Construction (Nonextruding and Resilient Bituminous Types)ASTM D1752 (2004a; R 2008)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0714002012FLUIDAPPLIEDWATERPROOFING 液体 防水剂 PDF

链接地址:http://www.mydoc123.com/p-984716.html