1、MIL-STD-710D 25 March 1991 SUPERSEDING 5) November 1970 MIL-STD-7 1OC MILITARY STANDARD SYNCHROS, 60 AND 400 Hz, SELIOCTION AND APPLICATION OF NOT MEASUREMENT SENSITIVE AMSC - N/A FSC 5990 PIB BUT ION STATWNT 8. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo
2、reproduction or networking permitted without license from IHS-,-,-MIL-STD-71OD 59 m 9999911 MIL-STD-71OD FOREWORD 1. of the Department of Defense. This military standard is approved for use by all Department8 and Agencies 2. Beneficial comments (recommendations, additions, deletions) and any pertine
3、nt data which may be of use in improving this document should be addressed to: Commandiag Officer, Naval Air Engineering Center, Systems Engineering and Standardization Department, Code 53, Lakehurst, NJ 08733-5100, by using the self-addressed Standardization Document Improvement Proposal (DD Form 1
4、426) appearing at the end of this document or by letter. ii Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-. MIL-STD-71OD CONTENTS Paraqraph Paqe 1 . SCOPE 1 1.1 Purpose . 1 1.2 scope 1 2 . APPLICABLE DOCUMENTS 1 2.1 Government documents 1 2.1.1 Spe
5、cifications and standards. 1 2 -2 Order of precedence . 2 3 . DEFINITIONS . + . 2 3.1 Synchro terminology- . 2 3.2 Nonstandard synchros 2 4 . GENERAL REQUIREMENTS 3 4.1 4.2 4.3 4.4 4.4.1 4.4.2 4.4.3 4.4.4 4.4.5 4.4.5.1 4.5 4.6 4.6.1 Choice of synchro types . Criteria for inclusion in the listing of
6、standard synchros . Standard synchros (functional listing) . Application and use . Electrical and physical tolerances Selection and alterations Tests and inspections for equipment design Tests and inspections for specification modifications Application . Unspecified characteristics . Use of nonstand
7、ard synchros . Test data New development . 3 3 6 7 7 7 8 8 8 8 8 8 8 5 . DETAIL REQUIREMENTS (Not applicable) 6 . NOTES 9 9 6.1 Intendeduse 9 6.2 IssueofDODISS 9 6.3 consideration of data requirements . 9 6.4 Subject term (key word) listing . 10 6.5 International standardization agreements 10 6.6 Ch
8、anges from previous issue . 10 iii Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-710D CONTENTS - Continued TABLES paue Tables I. Listing of standard synchros (as per 4.2) . . . . . . 4 II. Functional list of standard torque synchros . . . .
9、 . 6 III. Functional list of standard control synchros . . . . 7 APPENDIX A SYNCHRO INTERCHANGEABILITY GUIDE 11 Paragraph 10. 10.1 10.2 10.3 Table IV. V. APPENDIX B Paragraph 10. 10.1 Table VI. GENERAL. . 11 Purpose. 11 Military type synchros . . . . . . . . . . . . . . . 11 Standard synchros . . .
10、. . . . . . . . . . . . . . . 11 Synchro supersession data . . . . . . . . . . . . . . 12 Synchro obsolescence data . . . . . . . . . . . . . . 30 SYNCHRO GUIDANCE LIST OF PREFERRED NONSTANDARD ITEMS 39 GENERAL. . e 39 Purpose . . . . . . . . . . . . . . . . . . . . 39 Guidance list of preferred non
11、standard synchros . . . 39 iv Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-7LOD 57 M 9999933 O099993 = , MIL-STD-710D 1. SCOPE 1.1 Scope. Thia standard establishes requirements for the selection and application of synchro6 for use in milit
12、ary equipmenta. following: Included are ,the a. A list of synchros considered by the Department of Defense as stahdard for use in the design of military equipments. b. Requirements for the application of synchros in military equipment. - Specific requirements for the synchroa Usted in this standarda
13、re included in the latest issue of MIL-S-20708 and its associated specification sheets. 1.2 Purpose. The purpose of this standard is to: a. Provide the equipment designer with a list of synchros from a Qualified Products List (QPL) considered acceptable for military applications. - I b. Restrict the
14、 number of synchro types used in mfPLkeq equipment in order to provide effective logistic support of fiel6 ecpipnent, snbto concentrate effort in the improvement of manufacturing technfquerp for the synchro types included in this standard. C. Establish criteria pertinent to choice, application, and
15、use of synchros in military equipment. -_ i *= 2. APPLICABLE DOCUMENTS *- 2.1 Government documents. 2.1*1 SDecifications and standards. The following apecifications and standards fom a part of this standard to th extent specifiedherein. Unless otherwise specified, the issues of these documents are t
16、hose listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS) cited in the solicitation (see 6.2). SPECIFICTIONS .- MILITARY MIL-S-20708 Synchros, 60 and 400 Hz; and associated specification sheets. MIL-S-81963 Servocomponents, Precision Instrument, Rotating, C
17、ommon Requirements and Tests, General Specification for 1 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- - - _-_ MIL-STD-7LOD 59 m 99999LL 0099994 T I , MIL-STD-710D (Unless otherwise indicaled, copies qf federal and military specifications, standa
18、rds, and handbooks are available from the Standardization Document Order Desk, 700 Robbins Avenue, Building #4, Section D, Philadelpliia, PA 191 11-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this standard and references cited herein, the text of MIL-8-20708 shall
19、take precedence. laws and regulations unless a specific exemption has been obtained. 3. DEFINITIONS Nothing in this document or MIL-S-20708 supersedes applicable 3.1 Synchro terminoloqy. The meaning of terms used in this standard are those commonly encountered in synchro engineering practice. a. Syn
20、chro - A synchro is an electromechanical analog converter which, through electromagnetic means, gives an electrical output that is a function of its rotor position; or positions its rotor to an angle that is a function of the electrical input. control. There are two types of synchros-torque and (1)
21、Torque synchro - Provides a mechanical output. (2) Control synchro - Provides an electrical output. b. Synchro System - A synchro system is a oircuit containing one or more synchros that operate on angular information and convey this information to one or more remotely located indicators. synchro sy
22、stems. There are also two types of (1) Torque Synchro System - A torque synchro system is a system in which the transmitted signal does actual work. (2) Control Synchro System - A control synchro system is a system in which the transmitted signal controle a source of power which does actual work. 3.
23、2 Nonstandard svnchros. Any synchro selected which is not listed in Table I of this standard shall be considered a nonstandard synchro. A Patt Approval Request for use of a nonstandard item shall be submitted when specified by the contracting activity as a deliverable data item (see 6.3). 2 Provided
24、 by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-73OD 59 W 9999933 0099995 3 W MIL-STD-7 10D 4. GENERAL REQUIREMENTS 4.1 Choice of synchro tvpes. For simplification and standardization, the number of synchro types appearing in any particular equipment
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILSTD710D1991SYNCHROS60AND400HZSELECTIONANDAPPLICATIONOF60 400 赫兹 机型 选择 应用 PDF

链接地址:http://www.mydoc123.com/p-982466.html