NAVY MIL-S-23311 A-1977 SIGNAL UNDERWATER SOUND MARK 61 MOD 0 AND MARK 64 MOD 0《MARK 61 MOD 0 AND MARK 64 MOD 0水下声音信号》.pdf
《NAVY MIL-S-23311 A-1977 SIGNAL UNDERWATER SOUND MARK 61 MOD 0 AND MARK 64 MOD 0《MARK 61 MOD 0 AND MARK 64 MOD 0水下声音信号》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-S-23311 A-1977 SIGNAL UNDERWATER SOUND MARK 61 MOD 0 AND MARK 64 MOD 0《MARK 61 MOD 0 AND MARK 64 MOD 0水下声音信号》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-I DL 1332255 Pack, Shipping and Storage (For Six or Eight Signals, Underwater Sound) DL 2116941 Explosive Section, Underwater Sound Signal , Mk 4 Mod O, Loaded W DL 2116973 Explosive Section, Underwater
2、 Sound Signal, Mk 8 Mod O, Loaded Pack, Shipping and Storage (For Six Signals, Underwater Sound) DL 2127915 DL 2302101 Armi ng and Fi ring Mechanism , Mk 33 Mod O, Loaded DL 2302108 Signal, Underwater Sound, Mk 61 Mod O, Assembly, Loaded DL 2302109 Signal , Underwater Sound, Mk 64 Mod O, Assembly, L
3、oaded 69681 9 Armi ng Wire Assembly i OTHER PUBLICATIONS NAVAL SEA SYSTEMS COMMAND (Code Ident 53711) WR 54/131 Weapons Requirement, Pal letizing, Fleet Issue Unit Load, Signals, Underwater Sound Weapons Requirement, Pal 1 eti zing , Fleet Issue Unit Load, Signals, Underwater Sound WR 54/167 (Copies
4、 of specifications, standards drawings , and pub1 ications required by contractors in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer. ) Provided by IHSNot for ResaleNo reproduction or networking permitted withou
5、t license from IHS-,-,- -= MIL-S-2331 lA(AS) 3. REQUIREMENTS 3.1 Item identification. - The signals specified herein are hydro- statically operated explosive loaded ordnance items designed to detonate at nominal water depths of 60 or 800 feet, selectable prior to launch, for the purpose of providing
6、 a high energy underwater sound source. The SUS Mk 61 Mod O, DL 2302108, is composed of an arming and firing mechanism (A an explosive section, Mk 4 Mod O, DL 21 16941 ; and an arming wire assembly, Dwg. 696819. The SUS Mk 64 Mod O, DL 2302109, is composed of an A an explosive section, Mk 8 Mod O, D
7、L 2116973; and an arming wire assembly, Dwg. 696819. 3.2 Government furnished property 1 ist. - The shipping containers and explosive components may be Government furnished when so specified in the contract or order. 3.3 Performance. 3.3.1 Time from water entry to detonation. - The signal, when laun
8、ched from an aircraft, shall enter the water, sink to the preset depth and detonate. to detonation shall be as follows (see 4.5.1 ) . When detonation occurs, the time from water entry 4 (a) Shallow depth setting: 4 5 2 seconds (Cl). (b) Deep depth setting: 46 2 7 seconds (C2). 3.3.2 Detonation quali
9、ty. - The signal shall detonate high order as determined by the first bubble periods of Table I (see 4.5.2). TABLE I, FIRST BUBBLE PERIODS I Mk 61 1 Mk 64 I Depth setting (msec) Shallow 121 5 13 M1 O1 42 5 4 M103 Deep 19.5 5 1.8 M102 6.8 1- .6 M104 9 I 1 I 3.4 Design and construction. - The signal s
10、hall be fabricated and assembled in accordance with the drawings, parts lists and o$her documents 1 isted on DL 2302108 or DL 2302109, as specified in the contract or order. furnish sample units for first article inspection and approval (see 4.3). 3.5 First article. - When specified (see 6.2), .the
11、contractor shall 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MI L-S-23311 A (AS) 4. QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection. - Unless otherwise specified in the contract or order, the supplier is responsible for the per-
12、formance of all inspection requirements s specified herein. Except as otherwise specified in the contract or order, the supplier may use his or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. In addition, the Go
13、vernment reserves the right to perform any of the inspections set forth in the specification where such inspections are deemed necessary to assure suppl iec and services conform to prescribed requirements . 4.2 Classificationof inspections. - .The inspection requtrementc _. specified herein are clas
14、sified as follows. (a) First article inspection (see 4 (b) Qual i ty conformance inspection 4.3 First article inspection. - Un contract or order, a first article camp mitted for evaluation. The sample will 3). see 4.4). ess otherwise specified in the e of 80 signals shall be sub- be subjected b.y th
15、e Government to any or all of the examinations and tests specified ;n 4.5.1 and 4.5.2 of this specification and any or all requirements of the applicable drawings. The first article sample shall be manufactured using the same methods and materials prepared for production. Any production prior to acc
16、eptance of the first article sample shall be at the risk of the supplier. 4.3.1 First article performance test sampling. - Of the sample submitted. 20 each shall be tested under each Condition of Table II. Two defective units in any one of the samples of 20 total first article sample for MAJOR chara
17、cteristic defect shall reject the first article sample. 4.4 Quality conformance inspection. - The qual inspection shall verify that all characteristics of shall reject the . One CRITICAL ty conformance Section 3, Require- ments, and Section 5, Packaging, have been met. 4.4.1 Inspection lot. - The in
18、spection lot shall be as defined in MIL-STD-105, shall not exceed 3200 signals, and shall not be less than 1201 except in start-up and in final lots. multiples of pallet loads plus samples for destructive tests. 4.4.2 Inspection lot sample. - The inspection lot sample shall be selected and examined
19、to the data package in accordance with MIL-STD-105, Inspection Level II , with an Acceptable Quality Level (AQL) of 1 .O de- fects per hundred units for MAJOR characteristics and 2.5 defects per hundred units for MINOR characteristics, except as specified in 4.4.3. One CRITICAL defect shall reject t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILS23311A1977SIGNALUNDERWATERSOUNDMARK61MOD0ANDMARK64MOD0MARK61MOD0ANDMARK64MOD0 水下 声音 信号 PDF

链接地址:http://www.mydoc123.com/p-981591.html