NAVY MIL-R-6018 C-1966 REGULATOR OXYGEN DILUTER DEMAND《氧气调节器的稀释需求》.pdf
《NAVY MIL-R-6018 C-1966 REGULATOR OXYGEN DILUTER DEMAND《氧气调节器的稀释需求》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-R-6018 C-1966 REGULATOR OXYGEN DILUTER DEMAND《氧气调节器的稀释需求》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-R-601BC 16 9977706 OLB529B i.I MIL- R-6018C (ASG) 7 OCTOBER 1966 Supersedine 23 Cctober 1961 mL-6018 B( ASS) MILITARY SPECIFICATION REGULATOR, OXYGEN, DILUTER DEMAND This specification has been approved by the Department of the Air Force and by the Naval Air Systems Command. 1. SCOPE 11 This spe
2、cification covers a diluter demand oxygen regulator. 2. APPLICABLE DOCUMENTS 2.1 bids or request for proposal, form a part of this specification to the extent speci- fied herein: The following documents, of the issue in effect on date of invitation for SPECIFICATIONS Federal 0-“-236 QQ-P- 0-T-624 16
3、 PPP-B-591 PPP-B- 64 O PPP-B- 6 3 6 PPP-T-60 Military MIL-P-116 MIL-A-8625 MIL-F-22191 MIL-0-27210 STANDARDS Military MIL-STD-100 MIL-STD-105 !l!etrachloroethylene , Perchloroethylene, Trichloroethylene Technical Plating, Cadmium (Electrodeposited) Box, Fiberboard, Wood-Cleated Box, Fiberboard Box,
4、Fiberboard, Corrugated, Triple-Wall Tape; Pressure-Sensitive Adhesive, Waterproof, Technical Grade for Packaging Preservation, Methods of Anodic Coatings, for Aluminum and Aluminum Alloys Films, Transparent, Flexible, Heat Sealable, Oxygen, Aviators Breathing, Liquid and Gas for Packaging Applicatio
5、ns a Engineering Drawing Practices Sampling Procedures and Tables for Inspection by Attributes Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-6018C ( ASG) MIL-STD-129 MIL-STD-130 MS20913 MS33586 AN6004 Marking for Shipment and Storage Identifi
6、cation of US Military Property Plug, Square Head Pipe Thread Metals , Defiilition of Dissimilar Regulator - Diluter Demand Oxygen (Copies of specifications , standards , drawings, and publications required by .suppliers in connection with specific procurement functions should be obtained from the pr
7、ocuring activity or as directed by the contracting officer,) 3. REQUIREMENTS 3.1 Qualification,- The regulator furnished under this specification shall be a product which has been tested and has passed the qualification tests specified herein, and has been listed on or approved for listing on the ap
8、plicable Qualified Products List. 3.2 Materials.- 3.2.1 Nonferrous materials.- Nonferrous materials shall be used for all parts of the regulator except wher.e ferrous materials are essential. 3.2.2 Nonmetallic materials.- Any nonmetallic material that deteriorates or is adversely affected by continu
9、ed use with oxygen shall not be used. corrosion, dissimilar metals as defined in MS33586 shall qot be used in intimate contact with each other. 3.2.3 Dissimilar metals.- Unless suitably protected against electrolytic 3.2.4 Elastomers. - All elastomers , except silicone, shall have been manu- facture
10、d not more than 12 months prior to the date of regulator manufacture. cure date (quarter and year) shall be stamped on the elastomer component , provided there is sufficient area, silicone types, compound or silicone-coated cloth. which may cause objectionable or intolerableodors. Standard parts (MS
11、 or AN) shall be used wherever they are suitable for the purpose, and shall be identified on the drawing by their part numbers. Commercial utility parts such as screws, bolts, nuts, and cotter pins may be used, provided they possess suitable properties and are replaceable by the stand- ard parts wit
12、hout alteration, and provided the corresponding standard part numbers ar.e referenced in the parts list and, if practicable, on the contractors drawings. In the event there is no suitable corresponding standard part in effect on date of invitation for bide, commercial parts may be used provided they
13、 conform to all requirements of this specification. The Cure dates and age limitations shall not apply to the The demand diaphragm shall be fabricated of an approved silicone All elastomers shall be free from foreign agents 3.2.5 Standard parts.- 3.2.6 Interchangeability. - All parts having the same
14、 manufacturing part number shall be functionally and dimensionally interchangeable, facturers part numbers shall be in accordance with drawing number reqyirements of Changes in manu- MIL-STD-100. 2 -I_ Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
15、MIL-R-bOL8C Lb m 7997706 0185300 9 m MIL-R-6018C ( ASG.). . 3.3 Design.- The regulator shall be a diluter demand type Chat automatically mixes ambient air with supplied oxygenor providescontinuous flow of 100 percent oxygen when so adjusted. pounds per square inch gage (psig) to 1,800 psig. shall be
16、 in accordance with AN6004. indicator connection, manual controls, mounting plate and mounting holes shall be as shown on AN6004. The regulator shall operate on pressures.ranging from 50 The relative position of the inlet, outlet, flow The configuration and dimensions 3.3.1 Inlet screens.- 3.3.1.1 O
17、xygen inlet.- A 200-mesh screen or an equivalent filter shall be installed in the oxygen inlet so as to filter all supplied oxygen entering the regulator. 3.3.1.2 Ambient air inlet screen.- A screen not finer than 100 mesh nor coarser then 30 mesh shall be installed in the ambient air inlet so as to
18、 filter a11 ambient air that mixes with oxygen. 3.3.2 Flow indicator connection.- The regulator shall contain a 1/8-inchY female pipe thread, flow indicator connection. to a chamber in the regulator in which the pressure varies at least O;5 psig in the pressure range of O to 10 psig as a direct resu
19、lt of a flow in comparison through the regulator outlet. The flow through the outlet causing the variation in the pressure shall be as a result of applying a negative pressure (see 6.3.5) to the outlet with the diluter control in the normal oxygen position.and in the 100-percent oxygen position. The
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILR6018C1966REGULATOROXYGENDILUTERDEMAND 氧气 调节器 稀释 需求 PDF

链接地址:http://www.mydoc123.com/p-981306.html