NAVY MIL-PRF-32236-2007 GENERATOR CHLORINE PORTABLE ELECTROLYTIC (PECG)《电解氯气发生器 (PECG)》.pdf
《NAVY MIL-PRF-32236-2007 GENERATOR CHLORINE PORTABLE ELECTROLYTIC (PECG)《电解氯气发生器 (PECG)》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-PRF-32236-2007 GENERATOR CHLORINE PORTABLE ELECTROLYTIC (PECG)《电解氯气发生器 (PECG)》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、 INCH-POUND MIL-PRF-32236 30 January 2007 PERFORMANCE SPECIFICATION GENERATOR, CHLORINE PORTABLE ELECTROLYTIC (PECG) Comments, suggestions, or questions on this document should be addressed to: Commander, Naval Sea Systems Command, ATTN: SEA 05Q, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Nav
2、y Yard DC 20376-5160 or emailed to CommandStandardsnavy.mil, with the subject line “Document Comment”. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. AMSC N/A FSC 2090 Provided by IH
3、SNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-32236 CONTENTS PARAGRAPH PAGE 1. SCOPE1 1.1 Scope.12. APPLICABLE DOCUMENTS 12.1 General12.2 Government documents 12.2.1 Specifications, standards, and handbooks 12.2.2 Other Government documents, drawings, an
4、d publications.22.3 Non-Government publications22.4 Order of precedence33. REQUIREMENTS .33.1 First article 33.2 Design conditions33.2.1 Rated condition 43.2.2 General operational conditions.43.2.3 Environmental conditions.43.3 Reliability and maintainability43.4 Design life.43.5 Space and weight 43
5、.6 Selection of equipment43.7 Electrolytic chlorine generator cells53.7.1 Construction of the generating cells.53.8 Shipboard interface .53.8.1 PECG hose .53.8.2 PECG hose couplings.53.8.3 Chlorinator cell electrical isolation and grounding 53.8.4 PECG mounting .53.8.5 Input power 53.8.6 Portable ch
6、lorinator unit.53.8.7 Auxiliary pump unit .53.8.7.1 Performance characteristics.53.8.7.2 Motor .53.8.8 PECG cabling.63.8.9 PECG grounding 63.9 Materials .63.9.1 Electrolytically dissimilar metals .63.9.2 Mercury63.9.3 Painting 63.9.4 Noxious fumes and harmful effects63.9.5 Recycled, recovered, or en
7、vironmentally preferable materials 63.10 Threaded fasteners 63.11 Shock 63.12 PECG electrical requirements.63.12.1 Performance ratings63.12.2 AC power .63.12.3 Power supply7i Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-32236 PARAGRAPH PAG
8、E 3.12.4 Main power ON-OFF.73.12.5 Enclosures 73.12.6 Cooling method73.12.7 Safety ground .73.12.8 Insulation resistance .73.12.9 AC voltage withstand .73.12.10 Electromagnetic interference (EMI) emissions 73.12.11 Equipment capacitance and EMI filters73.12.12 Safety devices.73.12.12.1 Over-voltage/
9、over-current protection 73.12.12.2 Fuses73.12.12.3 Low flow protection 73.12.13 Connectors73.12.14 Internal wiring83.12.15 Indicator lights83.12.16 Voltage spike83.13 Safety 83.14 Human factors.83.15 Interchangeability83.16 Identification marking and label plates .83.17 Repair parts and stock spare
10、parts.83.18 Drawings.94. VERIFICATION 94.1 Classification of inspections .94.2 First article inspection.94.3 Conformance inspection .94.4 Visual and dimensional examination 94.5 Methods of inspection.104.5.1 Insulation resistance .104.5.2 General operation and temperature rise104.5.3 Voltage spike11
11、4.5.4 Electromagnetic interference114.5.5 Dielectric tests114.5.6 Ground continuity 114.5.7 Shock test .114.5.8 Performance test.114.5.9 Non-destructive testing.114.5.10 Hydrostatic testing115. PACKAGING.125.1 Packaging126. NOTES .126.1 Intended use 126.2 Acquisition requirements 126.3 Technical man
12、uals.126.4 Definitions 126.4.1 Auxiliary pump unit .12ii Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-32236 PARAGRAPH PAGE 6.4.2 Portable chlorinator unit.126.4.2.1 Chlorinator cells 126.4.2.2 Controller.126.4.2.3 Power supply assembly126.
13、4.3 Portable electrolytic chlorine generator (PECG)126.5 Subject term (key word) listing.12iii Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-32236 This specification is approved for use by all Departments and Agencies of the Department of D
14、efense. 1. SCOPE 1.1 Scope. This specification covers portable electrolytic chlorine generator (PECG) system components intended to provide protection against marine biological fouling (biofouling) in seawater piping systems on Navy Surface Ships. 2. APPLICABLE DOCUMENTS 2.1 General. The documents l
15、isted in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list,
16、document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbook
17、s form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. FEDERAL STANDARDS FED-STD-H28 - Screw-Thread Standards for Federal Services COMMERCIAL ITEM DESCRIPTIONS A-A-59004 - Anti-Galling
18、Compound, Thread Lubricating, Seizing Resistant, and Calcium Hydroxide Containing A-A-59326 - Coupling Halves, Quick-Disconnect, Cam-Locking Type DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-S-901 - Shock Tests, H.I. (High-Impact) Shipboard Machinery, Equipment, and Systems, Requirements for MIL-E-917 -
19、 Electric Power Equipment, Basic Requirements MIL-DTL-24640 - Cables, Light-Weight, Electric, for Shipboard Use, General Specification for MIL-DTL-24643 - Cables and Cords, Electric, Low Smoke, for Shipboard Use, General Specification for DEPARTMENT OF DEFENSE STANDARDS MIL-STD-108 - Definitions of
20、and Basic Requirements for Enclosures for Electric and Electronic Equipment MIL-STD-1310 - Standard Practice for Shipboard Bonding, Grounding, and Other Techniques for Electromagnetic Compatibility and Safety MIL-STD-1399-300 - Interface Standard for Shipboard Systems, Section 300, Electric Power, A
21、lternating Current (Metric) DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-237 - Electromagnetic Environmental Effects and Spectrum Supportability Guidance for the Acquisition Process 1 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-32236 MIL-HDBK
22、-454 - General Guidelines for Electronic Equipment MIL-HDBK-2036 - Preparation of Electronic Equipment Specifications (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or http:/assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Av
23、enue, Building 4D, Philadelphia, PA 19111-5094.) 2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents a
24、re those cited in the solicitation or contract. NAVSEA PUBLICATION NAVSEAINST 5100.3 - Mercury, Mercury Compounds, and Components Containing Mercury or Mercury Compounds; Control of (Copies of this document are available from IHS Inc., 15 Inverness Way East, Englewood, CO 80112 or online at .) 2.3 N
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILPRF322362007GENERATORCHLORINEPORTABLEELECTROLYTICPECG 电解 氯气 发生器 PECGPDF

链接地址:http://www.mydoc123.com/p-981016.html