NAVY MIL-E-28968-1971 ELECTRONIC SHOP TRANSPORTABLE EXPANDABLE EQUIPMENT REPAIR FACILITY《可扩大可运输带电实验设备》.pdf
《NAVY MIL-E-28968-1971 ELECTRONIC SHOP TRANSPORTABLE EXPANDABLE EQUIPMENT REPAIR FACILITY《可扩大可运输带电实验设备》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-E-28968-1971 ELECTRONIC SHOP TRANSPORTABLE EXPANDABLE EQUIPMENT REPAIR FACILITY《可扩大可运输带电实验设备》.pdf(54页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-E-28968 (Mc) 20 May 1971 MILITARY SPECIFIC AT ION ELECTRONIC SHOP, TRANSPORTABLE : EXPANDABLE, EQUIPMENT REPAIR FACILITY 1. SCOPE 1.1 This specification covers one transportable equipment repair,facil type of by elec expandable - ronic shop with repair and environmental equipment compactly insta
2、lled. 2. APPLICABLE DOCUMENTS 2.1 The following documents of the issue in effect on date of invitation for bids or request for proposal, form a part of the specification to the extent specified herein. SPEC IF ICAT IONS FEDERAL L-P-387 - Plastic Sheet, Laminated, Thermosetting TT-E-529 - Enamel, Alk
3、yd, Semigloss. ZZ-R-765 - Rubber, Silicone: Low-and-High-Tem- ZZ-T-416 - Tire Rebuilding and Tire and Tube DDD-T-86 - Tape, Textile, Cotton, General Purpose, PPP-F-3 20 - Fiberboard, Corrugated And Solid, (for Designation Plates) . perature and Tear Resistant. Repair Materials. (Unbleached, Bleached
4、 or Dyed) . Sheet Stock (Container Grade) And Cut Shapes. PPP-P-291 - Paperboard, Wrapping, Cushioning. MILITARY MIL-P- 1 16 - Preservation, Methods Of . MIL-T- 1 5 2 - Treatment, Moisture-and Fungus-Resistant, Of Communications, Electronic, And Associated Electrical Equipment. Cables and ground 3.3
5、.1.9.1 Power cables. The contractor shall furnish rods shall be supplied for each shelter as follows. four external power cable assemblies. shall be used to connect the 60-Hz source to the shelters. The other two cable assemblies shall connect the 400-Hz source to the shelters, The 60-Hz cable assem
6、blies shall be 75 feet long and consist of four No. 6 AWG stranded insulated conductors in a flexible neoprene jacket. The 400-Hz cable assemblies shall be 75 feet long and consist of four No. 10 AWG stranded insulated conductors in a flexible neoprene jacket. Each cable shall be terminated with con
7、nectors to mate with the shelterspower input receptacles on one end and with connectors to mate with the shelterslpower output receptacles on the other. addition, four 4-foot-long adaptei: cables shall be provided or connection of the power cables to the output studs of diesel engine generators PU-2
8、39/G, PU-344/G, PU-454/G or PU-608/G, The cable connectors (including the adapter cable connector) shall include a watertight cap and chain assembly. The intent of these cables and adapters is to provide input power to the shelters in the SSC or ESC from generator sets or for interconnection of the
9、power inputs of both shelters when operating in the ESC mode powered from a single power source. 3.3.10.9.2 Ground cable. The contractor shall furnish four ground cables 8 feet long. 3.3.10.9.3 Ground rods. The contractor shall furnish four ground rods 6 feet long complete with ground cable clamp an
10、d liTii handle. Two cable assemblies In 12 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-E-28968 i.19 9999906 0247895 4 m. MIL-E-28968 (MC) 3.3.10.10 Color codinq. Color coding for the 60-Hz and 400-Hz power distribution systems including the p
11、ower input cables shall be as follows: Black Phase A (Tl) Red Phase B (T2) Green Phase C (T3) White Neutral or Ground (TO) 3.3.11 Lishtinq. The shelters shabl be equipped with fluorescent lights, incandescent lights, and blackout protection. A minimum of 80- to 100-foot candles at work bench level s
12、hall be provided. All lighting circuits shall be 115 Y nominal, 60 Hz. The lighting circuits shall be protected by circuit breaker(s) located on the power control panel. 3.3.11.1 Fluorescent liqhtinq. General lighting of each shelter shall be by means of two rows of double tube shallow fluorescent f
13、ixtures with line f-ilters, .diffusing shields, radiation shields, and removable plastic covers. Each row of lights shall be controlled by a switch. The switches shall be located on the blackout interlock box. In the ESC, -two rows of quick-connect/disconnect, double fluorescent lighting fixtures sh
14、all be provided with line filters, diffusing- shields, Padiation shields, removable plastic covers and the capability of being connected into either shelters lighting system by a threaded keyed-type connector. 3.3.11.2 Incandescent liqhtinq. Incandescent lighting shall be furnished to illuminate the
15、 work benches. The lights shall be located under the equipment racks and be controlled by separate switches located near the lights. The light bulbs shall be of the rough service type and shall be vertically mounted in shock-absorbing bases. In the ESC, quick-connect/disconnect wall-mounted fixtures
16、 either shelter bench lighting system by threaded, keyed-type connector. Separate switches shall be located on wall-mounted fixtures . .shall be provided with capability to interconnect into Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-E-289b
17、49 W 9999906 OZL(783b b W MILIE-28968 (MC) 3.3.11.3 Blackout protection. To insure positive blackout protection, all shelter openings through the wall shall be made lighttight. Electrical interlocks shall be arranged so that if the outside doors are opmed, the lighting circuits shall be broken. The
18、shelters shall include a blackout curtain inside the doors. A neon lamp shall be mounted over the doors to give a small amount of illumination and the circuit shall permit the neon lamp to be left on continuously, Under blackout conditions, the doors interlock switches shall be operated to the IIOFF
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILE289681971ELECTRONICSHOPTRANSPORTABLEEXPANDABLEEQUIPMENTREPAIRFACILITY 扩大 运输 带电 实验 设备 PDF

链接地址:http://www.mydoc123.com/p-979036.html