NAVY MIL-DTL-32018-2001 CORD ASSEMBLY MILD DETONATION CANOPY PERIPHERY P N 837AS118《P N 837AS118型郁闭周边轻度爆震组》.pdf
《NAVY MIL-DTL-32018-2001 CORD ASSEMBLY MILD DETONATION CANOPY PERIPHERY P N 837AS118《P N 837AS118型郁闭周边轻度爆震组》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-32018-2001 CORD ASSEMBLY MILD DETONATION CANOPY PERIPHERY P N 837AS118《P N 837AS118型郁闭周边轻度爆震组》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、1 INCH-POUND I Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to the Commander, Indian Head Division, Naval Surface Warfare Center, Engineering Documentation Branch (Code 4230), 1 O1 Strauss Avenue
2、, Indian Head, Maryland 20640-5035, by using the Standardization Document Improvement . Proposal (DD Form 1426) appearing at the end of this document or by sending a letter. =MIL-DTL-320 18 13 March 2001 SUPERSEDING SCD 837AS118, Rev. B 10 August 1990 DETAIL SPECIFICATION CORD ASSEMBLY, MILD DETONAT
3、ION, CANOPY PERIPHERY, P/N 837AS118 This specijcation is approved for we by the Naval Sea Systems Command, Department of the Navy, and is available for tue by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the requirements for the manufacture
4、 and acceptance of the MG40 Canopy Periphery Mild Detonation Cord (MDC) Assembly, P/N 83AS118 , referred to in this document as cord assembly. 2. APPLICABLE DOCUMENTS 2.1 General. The docunients listed in this section are specified in sections 3 and 4 of this specification. This section does not inc
5、lude documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents specified in Sections
6、 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications and standards. The following specifications and standards form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those li
7、sted in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplements thereto, cited in the solicitation (see 6.2). AMSC NIA FSC 1377 DISTRIBUTION STATEn/lENT A: Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproducti
8、on or networking permitted without license from IHS-,-,-. MIL-DTL-320 18 SPECIFICATIONS m DEPARTMENT OF DEFENSE MIL-P-8 184 Plastic Sheet, Acrylic Modified MIL-DTL-2 1625 Design and Evaluation of Cartridges for Cartridge Actuated Devices STANDARDS DEPARTMENT OF DEFENSE MIL-STD-1 O0 Engineering Drawi
9、ng Practices MIL-STD-1168 Ammunition Lot Numbering and Ammunition Data Cards (Unless otherwise indicated, copies of DoD specifications are available from: Standardization Documents Order Desk, Bldg. 4D, 700 Robbins Avenue, Philadelphia, PA 19 1 1 1-5094.) 2.2.2 Other Government documents, drawings a
10、nd publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. SPECIFICATIONS NAVAL SEA SYSTEMS COMMAND (CAGE Code 5371 1) WS 5003 Hexanitro
11、stilbene (HNS), Explosive DRAWINGS NAVAL AIR SYSTEMS COMMAND (CAGE Code 30003) 837AS 1 18 Cord Assembly, Mild Detonating, Canopy Periphery , 837AS829 Cord Assembly, Mild Detonating, Test Fixture (Application for copies should be addressed to the Commanding Officer, Naval Air Technical Service Facili
12、ty, 700 Robins Avenue, Philadelphia, PA 19 1 1 1-5079.) 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-. MIL-DTL-32018 2.3 Non-Government publications and drawings. The following documents form a part of this document to the extent specified herei
13、n. Unless otherwise specified, the issues of the documents, which are DoD adopted, are those listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in DoDISS are the issues of the documents cited in the solicitation (see 6.2). AMER
14、ICAN SOCIETY FOR TESTING MATERIALS (ASTM) ASTM E 748 Standard Practice for N-Ray Inspection ASTM E 1742 Standard Practice for Radiographic Inspection (DoD adopted) (Application for copies of ASTMs should be sent to the American Society for Testing and Materials, 1 O0 Barr Harbor Drive, West Conshoho
15、cken, PA 19428-2959.) AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)/ AMERICAN SOCIETY FOR QUALITY CONTROL (ASQC) ANSIiASQC Z 1.4 Sampling Procedures and Tables for Inspection by Attributes (DoD adopted) (DoD activities may obtain copies from: Standardization Documents Order Desk, Bldg. 4D, 700 Robbin
16、s Avenue, Philadelphia, PA 191 1 1-5094. The private sector and other Government agencies may purchase copies from the American Society for Quality Control, P. O. Box 3005, 61 1 E Wisconsin Ave., Milwaukee, WI 53201-4606.) OEA AEROSPACE INC. (CAGE CODE 176 10) 5 1852-1 Detonating Cord Assembly, Cano
17、py Periphery (Application for copies should be addressed to OEA AEROSPACE INC., Highway 12 and Explosive Technology Road, Fairfield, CA 94533.) MC CORMICK SELPH, INC. (CAGE Code 0633 i) 8 19782-1 Detonating Cord Assembly, Canopy Periphery (Application for copies should be addressed to MC CORMICK SEL
18、PH, INC., 3601 Union Road, P.O. Box 6, Hollister, CA 95023.) 2.4 Order of Precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, 3 Provided by IHSNot for ResaleNo reproduction or
19、networking permitted without license from IHS-,-,-. MIL-DTL-32018 however, supercedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified in the contract or purchase order (see 6.2), a sample shall be subjected to first art
20、icle inspection as specified in section 4.3 (see 6.4). A first article inspection shall be required if: a. One or more years has passed since MDC or similar items have been manufactured, b. there has been a major turnover in personnel, c. there have been major changes to the production facility or d
21、. there has been a transfer of production to a new facility or site. 3.2 Design and construction. The MDC shall be manufactured to contractor drawings 8 19782- 1 or 5 1852- 1, as applicable, and shall meet the requirements of this specification with special effort to ensure inherent reliability so t
22、hat the units will consistently perform as specified. 3.3 Detonatining cord velocity. The detonation velocity of the detonating cord shall be 5,900 meters per second minimum when tested at -65F in accordance with 4.4.2. The detonation wave shall propagate through the entire length of the test specim
23、en. 3.4 Core load. The range of the explosive cord loading in grains per foot, divided by the minimal core load shall not exceed 24 percent when calculated from the detonating cord sample data obtained from 4.4.3. 3.5 MDC and booster interface. 3.5.1 Visual inspection. All MDC and booster interfaces
24、 manufactured under contract shall be visually inspected and screened for defects (see 4.2.1). 3.5.2 Leakage. All MDC and booster interfaces shall not exhibit a leak rate in excess of 1 x 10” cubic centimeters per second of air when tested as specified in 4.4.4. 3.5.3 Radiographic inspection. All MD
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL320182001CORDASSEMBLYMILDDETONATIONCANOPYPERIPHERYPN837AS118PN837AS118 郁闭 周边 轻度 爆震组 PDF

链接地址:http://www.mydoc123.com/p-978765.html