1、 INCH-POUND MIL-DTL-32010A (OS) 03 August 2006 SUPESEDING MIL-DTL-32010 (OS) 23 January 1998 DETAIL SPECIFICATION FIRE EXTINGUISHER CARTRIDGE, CCU-90/A (MH92) This specification is approved for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by all Departments
2、and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the requirements for the manufacture and acceptance of the CCU-90/A Fire Extinguisher Cartridge, referred to herein as the “cartridge.” 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section a
3、re specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are caut
4、ioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this do
5、cument to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-D-21625 Design and Evaluation of Cartridges for Cartridge Actuated Devices Comments, suggestions, or questions on
6、 this document should be addressed to Commander, Indian Head Division, Naval Surface Warfare Center, Technical Information Products Branch (E143), 101 Strauss Avenue, Indian Head, MD 20640 5035, or emailed to amanda.pennnavy.mil. Since contact information can change, you may want to verify the curre
7、ncy of this information using the ASSIST Online database at http:/assist.daps.dla.mil. AMSC N/A FSC 1377 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-32010A
8、(OS) 2 DEPARTMENT OF DEFENSE STANDARDS MIL-STD-810 Environmental Engineering Considerations And Laboratory Tests MIL-STD-1168 Ammunition Lot Numbering And Ammunition Data Card (Copies of these documents are available online at http:/assist.daps.dla.mil/ or from the Standardization Documents Order De
9、sk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues of
10、 these documents are those cited in the solicitation or contract. DRAWINGS NAVAL AIR SYSTEMS COMMAND (CAGE Code 30003) DL1512AS105 CCU-90/A Cartridge, Fire Extinguisher 298AS105 Closed Chamber, 1.22 Cu. Inch Assembly (Application for copies of these specifications and drawings should be addressed to
11、 the Commander, Indian Head Division, Naval Surface Warfare Center (E143), 101 Strauss Avenue, Indian Head, MD 20640-5035.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents
12、are those cited in the solicitation or contract. AEROSPACE INDUSTRIES OF AMERICA, INC. NASM21044 Nut, Self-Locking, Hexagon, Regular Height, 250F, 125 KSI FTU and 60 KSI FTU (Copies of this document are available online at http:/ or from the Aerospace Industries Association, 1000 Wilson Boulevard, S
13、uite 1700, Arlington, VA 22209-3928) AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTM E 1742 Standard Practice for Radiographic Examination (Copies of this document are available online at http:/www.astm.org or from the American Society for Testing and Materials Customer Service, 100 Barr Harb
14、or Drive, West Conshohocken, PA 19428-2959.) 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however supersedes applicable laws and regulations unless a specif
15、ic exemption has been obtained. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-32010A (OS) 3 3. REQUIREMENTS 3.1 First article. When specified (see 6.3), a sample shall be subjected to first article inspection in accordance with 4.2.1. 3.2 P
16、rimary components. Only one lot of primary components shall be used in each lot of fire extinguisher cartridges, although a primary component lot may be used in more than one fire extinguisher cartridge lot. The squib subassembly and output charge in the squib subassembly are considered primary comp
17、onents. 3.3 Cartridge production. The cartridges shall be manufactured in accordance with DL1512AS105 and the documents listed thereon. Each squib subassembly shall meet the requirements of 3.3.1 through 3.3.1.2 and each cartridge shall meet the requirements of 3.3.2 through 3.3.2.4. Failure of any
18、cartridge to meet the applicable requirements of 3.3 shall result in rejection of that unit. 3.3.1 Squib subassembly inspection. 3.3.1.1 Visual inspection. All squib subassemblies manufactured under contract shall be visually inspected and screened for defects as outlined in 4.3.1. 3.3.1.2 Leakage.
19、Squib subassemblies shall not exhibit a leak rate in excess of 1 10-5 cubic centimeters per second (cm3/s) of air when tested in accordance with 4.3.2. 3.3.2 Cartridge inspection. 3.3.2.1 Visual inspection. All cartridges manufactured under contract shall be visually inspected and screened for defec
20、ts as outlined in 4.3.1. 3.3.2.2 Radiographic inspection. Cartridges shall show proper assembly, presence of parts, and sealing when examined radiographically in accordance with 4.3.3.2. 3.3.2.3 Bridgewire resistance. Cartridges shall exhibit a bridgewire resistance between 0.90 and 1.40 ohms when t
21、ested in accordance with 4.3.4. 3.3.2.4 Torque. The crimp interface between the housing and insulator shall withstand 14 inch-pounds of torque without rotation of the insulator when tested in accordance with 4.3.5. 3.4 Cartridge performance. Cartridges shall be capable of meeting all requirements of
22、 3.4.4. 3.4.1 Vibration. There shall be no evidence of deformation or derangement of components. The cartridge shall not autoignite, shall be safe to handle, and shall meet the requirements of 3.3.2.2 and 3.4.4 following vibration testing of 4.3.6. 3.4.2 Temperature and humidity (T & H) cycling. The
23、 cartridges shall meet the requirements of 3.3.2.2 and 3.4.4 after being exposed to the T & H cycle in accordance with 4.3.7. 3.4.3 Shock. The cartridges shall meet the requirements of 3.3.2.2 and 3.4.4 following shock testing of 4.3.8. Provided by IHSNot for ResaleNo reproduction or networking perm
24、itted without license from IHS-,-,-MIL-DTL-32010A (OS) 4 3.4.4 Ballistic requirements. Cartridges from each production and first article lot shall meet the requirements of 3.4.4.1 through 3.4.4.3 when subjected to the tests of 4.3.9. 3.4.4.1 Cartridge pressure. The cartridge shall provide: a. The lo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL32010A2006FIREEXTINGUISHERCARTRIDGECCU90AMH92CCU90AMH92 型弹筒 灭火器 PDF

链接地址:http://www.mydoc123.com/p-978760.html