NAVY A-A-60003-1997 PARTITIONS TOILET COMPLETE [Superseded NAVY RR-P-1352 C CANC NOTICE 1 NAVY RR-P-1352 C NAVY RR-P-1352 B NAVY RR-P-1352 A (2) NAVY RR-P-1352 A INT AMD 1 NAVY RR-.pdf
《NAVY A-A-60003-1997 PARTITIONS TOILET COMPLETE [Superseded NAVY RR-P-1352 C CANC NOTICE 1 NAVY RR-P-1352 C NAVY RR-P-1352 B NAVY RR-P-1352 A (2) NAVY RR-P-1352 A INT AMD 1 NAVY RR-.pdf》由会员分享,可在线阅读,更多相关《NAVY A-A-60003-1997 PARTITIONS TOILET COMPLETE [Superseded NAVY RR-P-1352 C CANC NOTICE 1 NAVY RR-P-1352 C NAVY RR-P-1352 B NAVY RR-P-1352 A (2) NAVY RR-P-1352 A INT AMD 1 NAVY RR-.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、INCH-POUND A-A-60003 August 22.1997 SUPERSEDING February 8,1989 RR-P-1352C COMMERCIAL ITEM DESCRIPTION PARTITIONS, TOILET, COMPLETE The General Services Administration has authorized the use of this commercial item description for all Federal agencies. l. SCOPE. This commercial item description (CID
2、) covers toilet partitions including all pilasters (stiles), panels, doors, fittings, hardware, and fasteners necessary for complete installation. 2. CLASSIFICATION. The partitions will be of the following types, styles, and finishes as specified (see 7.2): Types: I - Toilet enclosure (compartment)
3、II - Room entrance screen III - Urinal screen Styles: A - Floor supported B - Ceiling hung C - Overhead braced D - Floor-to-ceiling hung F - Overhead braced - alcove E - Wall hung Finish: 1 - Baked enamel 2 - Stainless steel 3 - Laminated plastic 4 - Solid plastic: phenolic 5 - Solid plastic: polyet
4、hylene Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data which may improve this document should be sent to: Commanding Officer (Code 15E2), Naval Construction Battalion Center, 1000 23rd Avenue, Port Hueneme, CA 93043-4301, by using the Standardization Doc
5、ument Improvement Proposal D Form 1426) appearing at the end of this I document or by letter. I AMSC N/A FSC 5670 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3. SALIENT cHARAcTERIsTlcs. 3.1 DescriDtion. Toilet partitions include toilet enclosures
6、, room entrance screens and urinal screens. Toilet partitions shall be metal, solid plastic, or plastic laminated construction. The partitions shall be furnished with all fastenings, fittings, and hardware necessary for complete installation. 3.1.1 Toilet enclosures. Floor supported toilet enclosure
7、s are intended for general use; however, not less than 2-inch (5 1 millimetre (m) concrete floor is required for adequate support. Overhead braced toilet enclosures shall be specified where the floor is less than 2 inches (5 1 mm) of concrete, or pilaster is not perpendicular to the panel which it s
8、upports. Ceiling supported toilet enclosures should be specified where adequate support is provided by the ceiling. Toilet enclosure dimensions shall be as specified (see 7.2). 3. l. l. 1 Type I toilet enclosures. Toilet enclosures shall consist of doors, panels, and pilasters to form an enclosure a
9、round the toilet. When toilet compartments for handicapped are specified (see 7.2), they shall be in compliance with the current American Disabilities Act (ADA) guidelines. Pilaster size may vary to suit the job conditions. 3 .l. 1.2 Style A floor supported enclosures. Style A floor supported enclos
10、ures shall be floor supported with pilasters extending from the floor to the top edge of the panels. Top edges of doors, panels, and pilasters shall be flush, and bottom edges of pilasters shall extend to the floor. 3 .l. 1.3 Style B ceiling hung enclosures. Style B ceiling hung toilet enclosures sh
11、all have pilasters hung from overhead construction. Pilasters shall extend from the ceiling to the bottom edge of the panels. Top edges of wall posts shall be flush with top edges of doors. Bottom edges of doors, panels, pilasters, and wall posts shall be flush. 3.1.1.4 Style C overhead braced enclo
12、sure. Style C overhead braced toilet enclosures shall be braced with pilasters extending from the floor to the headrail bracing. Wall posts shall extend from headrail bracing to the bottom edge of doors. Pilasters adjacent to walls may be flush with bottom of doors provided they are attached to head
13、rail. 3.1.1.5 Style F overhead braced alcove type. Style F overhead braced alcove toilet enclosures shall be overhead braced with pilasters extending from the floor to the headrail bracing. Panel and stile shall be fixed to the adjoining walls. 3.1.2 Type II room entrance screens. Room entrance scre
14、ens shall consist of panels and pilasters or posts as required for the style specified. Screen length and height shall be as specified (see 7.2). . . 3.1.2.1 Style A floor supported entrance screens. Style A floor supported room entrance screens shall consist of a panel and pilaster as specified for
15、 style A toilet enclosures. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A40003 3.1.2.2 Style B ceiling hung entrance screens. Style B ceiling hung room entrance screens shall consist of a panel and pilaster as described for style B toilet enc
16、losures. 3.1.2.3 Style C overhead braced entrance screen. Style C overhead braced room entrance screens shall consist of pilasters, panels, and headrail bracing. The panels shall be fixed to the wall and pilaster. 3.1.2.4 Style E floor-to-ceiling post supported entrance screen. Style E floor-to-ceil
17、ing post supported room entrance screens shall consist of a panel and supporting post which extends from the floor to the ceiling. 3.1.3 Type III urinal screens. Urinal screens shall consist of panels and pilasters or post as required for style and dimensions as specified (see 7.2). 3.1.3.1 Style A
18、floor supported urinal screen. Style A floor supported urinal screens shall consist of panel and pilaster as described for style A room entrance screens. Floor supported pilasters shall be designed for fastening to the structural slab through an integrally welded split channel or cross bar leveling
19、device mounted on two stud bolts. 3.1.3.2 Style B ceiling hung urinal screen. Style B ceiling supported urinal screens shall consist of panel and pilaster as described for style B toilet enclosures. Ceiling hung pilasters shall be designed for bolting to the overhead structural support through an in
20、tegrally welded split channel or cross bar leveling device mounted on two stud bolts. 3.1.3.3 Style C overhead braced screen. Style C overhead braced screens shall consist of panels, posts, and headrail. Posts shall extend Erom floor to the top of the panels. Panels shall be fixed to the post and wa
21、lls. Overhead braced pilasters shall be designed for fastening to the finished floor through an integrally welded split channel or cross bar leveling device mounted on two stud bolts. 3.1.3.4 Style D wall hung urinal screen. Style D wall hung urinal screens shall consist of a panel designed to be su
22、pported by the wall. No pilaster or post support shall be needed. Wall hung urinal screens are intended for use only where the supporting walls are concrete, masonry, or other construction capable of providing adequate anchorage to ensure a rigid installation. 3 - 1.3.5 Style E floor-to-ceiling post
23、 supported urinal screen. Style E floor-to-ceiling post supported urinal screens shall consist of a panel and post as described for style E room entrance screens. 3.1.4 Finish. Finish shall be as specified (see 2. and 7.2). Finish shall be highly resistant to alkalis, urine, and other common toilet
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA600031997PARTITIONSTOILETCOMPLETESUPERSEDEDNAVYRRP1352CCANCNOTICE1NAVYRRP1352CNAVYRRP1352BNAVYRRP1352A2NAVYRRP1352AINTAMD1NAVYRRPDF

链接地址:http://www.mydoc123.com/p-976483.html