NAVY A-A-59940-2013 CONNECTORS FIBER OPTIC SINGLE OR MULTIPLE FIBER GENERAL SPECIFICATION FOR.pdf
《NAVY A-A-59940-2013 CONNECTORS FIBER OPTIC SINGLE OR MULTIPLE FIBER GENERAL SPECIFICATION FOR.pdf》由会员分享,可在线阅读,更多相关《NAVY A-A-59940-2013 CONNECTORS FIBER OPTIC SINGLE OR MULTIPLE FIBER GENERAL SPECIFICATION FOR.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to: Commander, Naval Sea Systems Command, ATTN: SEA 05S, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard DC 20376-5160 or emailed to CommandStandard
2、snavy.mil, with the subject line “Document Comment”. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.dla.mil. FSC 6060 METRIC A-A-59940 19 November 2013 COMMERCIAL ITEM DESCRIPTION CONNECTORS, FIB
3、ER OPTIC, SINGLE OR MULTIPLE FIBER, GENERAL SPECIFICATION FOR The General Services Administration has authorized the use of this commercial item description, for all federal agencies. 1. SCOPE. This commercial item description (CID) covers the general requirements for connectors with the following a
4、ttributes: low optical loss performance, high reliability, and compatible with loose tube, tight buffered, and ribbon multimode and single-mode optical fiber. 2. CLASSIFICATION. This CID uses a classification system that is included in the Part or Identification Number (PIN) (see 7.2). 2.1 Terminati
5、on process. Connector termination process shall be designated as indicated in table I. TABLE I. Connector termination process. Termination process Designation Epoxy polish 1 Quick-connect fusion splice 2 Quick-connect mechanical splice 3 2.2 Type. Connectors covered by this specification shall be of
6、 the following types as specified (see 3.1): a. Type 1 multimode (MM) Ultra Physical Contact (UPC). b. Type 2 single-mode (SM) UPC. c. Type 3 single-mode (SM) Angled Physical Contact (APC). 2.3 Fiber/cable type compatibility. The connector fiber/cable compatibility type is designated by a single let
7、ter as indicated in table II. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59940 2 TABLE II. Fiber/cable configuration type. Fiber/cable configuration type Designation Buffered fiber 1/ A OFCC tight structure 2/ B OFCC non-tight structure 3/ C
8、 Ribbon 4/ D NOTES: 1/ The connector can accept buffered fiber with no individual protective jacket or strength member. 2/ The connector can accept buffered fiber with an individual protective jacket and strength member. The cable is considered to be of tight construction. This includes cable in acc
9、ordance with MIL-PRF-85045/16. 3/ The connector can accept buffered fiber with an individual protective jacket and strength member. The cable is considered a non-tight construction. This includes furcation units in accordance with A-A-59729. 4/ The connector can accept fibers in a ribbon. 2.4 Housin
10、g type configurations. Housing type configurations are as follows: a. Simplex one optical fiber/ferrule/one ferrule. b. Duplex one optical fiber/ferrule/two ferrules. c. Multiple fiber terminus multiple optical fibers/one ferrule. 2.5 Temperature range. Temperature range designations are specified i
11、n table III. TABLE III. Temperature range designation. Temperature range designation Operating temperature Non-operating temperature Storage temperature C (F) C (F) C (F) 1 -28 to +65 (-18.4 to +149) -40 to +70 (-40 to +158) -40 to +70 (-40 to +158) 3. SALIENT CHARACTERISTICS. 3.1 Specification shee
12、ts. Individual item requirements shall be as specified herein and in accordance with the applicable specification sheet. In the event of any conflict between the requirements of this CID and the specification sheets, the latter shall govern. 3.1.1 Interchangeability and intermateability. All connect
13、ors of the same design (i.e., the same part number and configuration) shall be physically and functionally interchangeable without need for modification of such items or of the mating equipment. 3.1.2 Interface dimensions. The interface dimensions of the connector shall be as defined herein and in t
14、he applicable specification sheet (see 3.1). 3.1.3 Cable strain relief. The design of connector cable configuration B, C, and D shall include strain relief for capture of the aramid yarn in the cable. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A
15、-A-59940 3 3.1.4 Bend limiter. The design of all cable configurations shall include a bend limiter (boot) at the rear of the connector. 3.1.5 Optical fiber cable compatibility. Cable designation A connectors have 900-micron fiber and shall properly terminate to 0.900+0.050-millimeter buffered optica
16、l fiber. Cable designation B connectors shall properly terminate to MIL-PRF-85045/16 single-fiber cable. Cable designation C connectors shall properly terminate to commercial single-fiber cable with an outer diameter of 1.8 to 2.4 millimeters. Cable designation D connectors shall properly terminate
17、to commercial ribbon cable. 3.1.6 Optical fiber attachment. Optical fiber attachment inside the ferrule and barrel (part into which ferrule is inserted) shall be provided by adhesive bonding. Single fiber cable strength member attachment for epoxy polish connectors shall be provided by crimping. 3.1
18、.6.1 Optical fiber termination (quick-connect connector). The optical fiber termination methodologies used for affixing a quick-connect connector to the fibers to be attached shall meet the requirements specified herein. 3.1.6.1.1 Fusion/mechanical fiber splice (quick-connect connector). When utiliz
19、ed, the mechanical or fusion fiber splice shall be integral to the ferrule body and include the splice housing. 3.1.6.1.2 Fusion/mechanical fiber splice housing (quick-connect connector). The mechanical or fusion fiber splice housing shall restore the environmental and mechanical integrity of the op
20、tical fiber terminating to it and meet the performance requirements specified herein. The housing shall not affect the operation of the connector or associated tooling when installing or removing the connector. 3.1.7 Color. In accordance with EIA-339, a portion of the connector housing or boot shall
21、 be blue or yellow for single-mode UPC, green for single-mode APC, and beige or slate for multimode. 3.1.8 Endface geometry (quick-connect connector only, single fiber). Connectors with pre-polished fiber stubs shall utilize an enhanced, domed end, physical contact (PC) polish that results in ferrul
22、e endface with geometric parameters as follows: a. Radius of curvature (ROC): 7 millimeters to 25 millimeters. b. Apex offset: 50 microns. c. Fiber height: (1) Protrusion: 0.05 microns (50 nanometers). (2) Undercut: The maximum value (limit) for the spherical undercut is dependent upon the ROC of th
23、e connector under test (see table IV). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59940 4 TABLE IV. Maximum acceptable undercut. ROC (mm) Undercut (nm) 7 125 8 125 9 125 10 125 11 115 12 106 13 98 14 91 15 85 16 80 17 75 18 72 19 68 20 65 21
24、 62 22 59 23 56 24 53 25 50 3.1.8.1 APC endface geometry (quick-connect connector only, single fiber). Connectors with pre-polished APC fiber stubs shall utilize a polish that results in ferrule endface with geometric parameters as follows: a. Radius of curvature (ROC): 5 millimeters to 12 millimete
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA599402013CONNECTORSFIBEROPTICSINGLEORMULTIPLEFIBERGENERALSPECIFICATIONFORPDF

链接地址:http://www.mydoc123.com/p-976481.html