NAVY A-A-59822-2009 PLUG ASSEMBLIES GRIPPERS OD AND ID TYPES FOR TEMPORARY PRESSURE TESTING OF WATER OIL AND GAS TRANSMISSION PIPING《水 油和气输送管道临时压力试验用OD和ID型抓爪插头组件》.pdf
《NAVY A-A-59822-2009 PLUG ASSEMBLIES GRIPPERS OD AND ID TYPES FOR TEMPORARY PRESSURE TESTING OF WATER OIL AND GAS TRANSMISSION PIPING《水 油和气输送管道临时压力试验用OD和ID型抓爪插头组件》.pdf》由会员分享,可在线阅读,更多相关《NAVY A-A-59822-2009 PLUG ASSEMBLIES GRIPPERS OD AND ID TYPES FOR TEMPORARY PRESSURE TESTING OF WATER OIL AND GAS TRANSMISSION PIPING《水 油和气输送管道临时压力试验用OD和ID型抓爪插头组件》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to: Commander, Naval Sea Systems Command, ATTN: SEA 05M2, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard DC 20376-5160 or emailed to CommandStandar
2、dsnavy.mil, with the subject line “Document Comment”. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. FSC 4730 INCH-POUND A-A-59822 12 February 2009 COMMERCIAL ITEM DESCRIPTION PLUG A
3、SSEMBLIES, GRIPPERS, OD AND ID TYPES FOR TEMPORARY PRESSURE TESTING OF WATER, OIL AND GAS TRANSMISSION PIPING The General Services Administration has authorized the use of this commercial item description, for all federal agencies. 1. SCOPE. This commercial item description describes high pressure h
4、ydrostatic test plugs and fittings (hereafter referred to jointly as “plugs”) that can be used to make mechanical attachments to pipes, tubes, and other piping fittings (hereafter referred to jointly as “pipes”), for the purposes of isolating components and making pressure seal boundaries for hydros
5、tatic testing. As a secondary function, the test plug provides a means for making a connection of the hydrostatic test medium and pressure. 2. CLASSIFICATION. The hydrostatic test plugs shall be of the following types: Type I Hydrostatic test plugs that are installed in and seal on the pipe internal
6、 diameter. Type II Hydrostatic test plugs that are installed on and seal on the pipe outside diameter. 3. SALIENT CHARACTERISTICS. 3.1 Size. 3.1.1 Standard sizes. 3.1.1.1 Type I. Type I hydrostatic test plugs shall be provided in sizes that can be used in the series of pipe diameters and schedules o
7、r classes shown in table I. TABLE I. Pipe sizes for type I hydrostatic test plugs. Pipe Material Schedule or Class National Pipe Sizes inches 40 1, 1, 1, 2, 2, 3, 3, 4, 5, 6, 8, 10 80 1, 1, 1, 2, 2, 3, 3, 4, 5, 6, 8, 10 120 4, 5, 6, 8, 10 160 1, 1, 112, 2, 212, 3, 4, 5, 6, 8, 10 XS 10 Standard Steel
8、 Pipe XXS 1, 1, 1, 2, 2, 3, 3, 4, 5, 6, 8 5 S 1, 1, 1, 2, 2, 3, 3, 4, 5, 6, 8 Stainless Steel Pipe 10 S 1, 1, 112, 2, 212, 3, 312, 4, 5, 6, 8 90-10 Copper-Nickel Pipe/Tubing 200 As defined in MIL-T-16420 200 700 1650 3300 70-30 Copper-Nickel Pipe/Tubing 6000 As defined in MIL-T-16420 Provided by IHS
9、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59822 2 3.1.1.2 Type II. Type II hydrostatic test plugs shall be sized to apply to the following standard nominal pipe sizes: -inch, 38-inch, -inch, -inch, 1-inch, 1-inch, 1-inch, 2-inch, 2-inch, and 3-inch, or as
10、 defined by MIL-T-16420. 3.1.1.3 Tolerances. For Type I or II plugs intended for use in standard pipe sizes, the dimensions shall be such that the plug can be properly set and used in pipes with diametrical and wall thickness dimensional tolerance ranges as specified in table II. TABLE II. Tolerance
11、s for standard pipe. Type of Pipe Standard for Outside Diameter Tolerance Standard for Wall Thickness Tolerance Standard Steel Pipe ASTM A530/A530M ASME B36.10 Stainless Steel Pipe ASTM A530/A530M ASME B36.19 Copper-Nickel Pipe/Tubing MIL-T-16420 MIL-T-16420 3.1.2 Non-standard sizes. For plugs requi
12、red for service in non-standard dimensioned pipes, the dimensional design shall be suitable for use in outside and inside diameter tolerance ranges, and/or wall thickness tolerance ranges, as provided by the purchaser. 3.2 Marking. Hydrostatic test plug assemblies shall be marked by stamping or othe
13、r permanent means that will not be subject to degradation by corrosion or contact with water. Marking shall be done on a prominent location that does not interfere with the sealing or gripping function. Characters shall be at least -inch high. All assemblies shall be marked with the following: a. Ma
14、nufacturers name, abbreviation, acronym, or symbol b. Manufacturers part number c. Maximum pressure rating of the plug in pounds per square inch gauge (see 3.4.4) d. Notation if a safety gag is required (see 3.4.9) e. Drawing Number f. Material Type g. Material Specification h. Additionally, the fol
15、lowing items shall be included in the marking for the specific hydrostatic test plug types: Type I: The internal pipe diameter range, in inches, over which the hydrostatic test plug can be installed and set properly. Type II: The Nominal Pipe Size (NPS) diameter, in inches, for which the hydrostatic
16、 test plug is intended. 3.3 Materials. All pressure containing materials shall be metallic except for the expandable mechanical stopper material, and any other seals or o-rings required. Materials shall be selected based on a service temperature range of 60 to 120 F and shall be resistant to corrosi
17、on or degradation in fresh water service. 3.4 Design details. 3.4.1 General design. In general, hydrostatic test plugs shall contain: expandable mechanical stopper seals or other sealing devices to seal against the surface of the pipe being tested, gripper assemblies to grip the surface of the pipe
18、in order to ensure against ejection of the plug during hydrostatic testing, and wedging devices activated by tightening the plug fitting(s) in order to activate the gripping elements and the seals. See figures 1 and 2 for a typical OD and ID type design. Provided by IHSNot for ResaleNo reproduction
19、or networking permitted without license from IHS-,-,-A-A-59822 3 FIGURE 1. Typical OD hydro test plug (for information only). FIGURE 2. Typical ID hydro test plug (for information only). 3.4.2 Porting. The hydrostatic test plugs shall have a central port that connects the pressurized region of the p
20、ipe being hydrostatically tested to an outside, external fitting to which the hydrostatic pressure source pump can be connected. This fitting shall have an appropriately sized male or female pipe thread, conforming to ASME B1.20.1 tapered National Pipe Thread (NPT) inch-series threads or as specifie
21、d by the buyer. The hydrostatic plug shall be supplied with a pipe cap or plug which can be used to seal the port. 3.4.3 Design of pressurized components. All components subjected to the hydrostatic pressure shall be designed in accordance with the ASME Boiler and Pressure Vessel Code, for a maximum
22、 allowable working pressure at least 1.5 times as great as the pressure rating stamped on the fitting. All components subjected to hydrostatic pressure shall be designed in accordance with the ASME Boiler and Pressure Vessel Code Section B31.1 or alternate method of design as approved by NAVSEA. The
23、 design shall be for the maximum allowable working pressure of the components using the material allowable stresses as dictated by the Code. Designs for which the maximum allowable working pressure cannot be computed with satisfactory assurance, refer to ASME Boiler and Pressure Vessel Code Section
24、B31.1 or the ASME Boiler and Pressure Vessel Code Section VIII (Proof tests to establish maximum allowable working pressure). All hydrostatic test plugs shall be proven through hydrostatic testing using a test fixture representative of the intended final use. The test medium shall be fresh water at
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA598222009PLUGASSEMBLIESGRIPPERSODANDIDTYPESFORTEMPORARYPRESSURETESTINGOFWATEROILANDGASTRANSMISSIONPIPING

链接地址:http://www.mydoc123.com/p-976470.html