1、 JEDEC PUBLICATION Beaded Thermocouple Temperature Measurement of Semiconductor Packages JEP140 JUNE 2002, rReaffirmed: June 2006 JEDEC SOLID STATE TECHNOLOGY ASSOCIATION NOTICE JEDEC standards and publications contain material that has been prepared, reviewed, and approved through the JEDEC Board o
2、f Directors level and subsequently reviewed and approved by the JEDEC legal counsel. JEDEC standards and publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and
3、 assisting the purchaser in selecting and obtaining with minimum delay the proper product for use by those other than JEDEC members, whether the standard is to be used either domestically or internationally. JEDEC standards and publications are adopted without regard to whether or not their adoption
4、 may involve patents or articles, materials, or processes. By such action JEDEC does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the JEDEC standards or publications. The information included in JEDEC standards and publications represen
5、ts a sound approach to product specification and application, principally from the solid state device manufacturer viewpoint. Within the JEDEC organization there are procedures whereby an JEDEC standard or publication may be further processed and ultimately become an ANSI/EIA standard. No claims to
6、be in conformance with this standard may be made unless all requirements stated in the standard are met. Inquiries, comments, and suggestions relative to the content of this JEDEC standard or publication should be addressed to JEDEC at the address below, or call (703)907-7559 or www.jedec.org Publis
7、hed by JEDEC Solid State Technology Association 2006 2500 Wilson Boulevard Arlington, VA 22201-3834 This document may be downloaded free of charge; however JEDEC retains the copyright on this material. By downloading this file the individual agrees not to charge for or resell the resulting material.
8、 PRICE: Please refer to the current Catalog of JEDEC Engineering Standards and Publications or call Global Engineering Documents, USA and Canada 1-800-854-7179, International (303) 397-7956 Printed in the U.S.A. All rights reservedPLEASE! DONT VIOLATE THE LAW! This document is copyrighted by JEDEC a
9、nd may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For information, contact: JEDEC Solid State Technology Association 2500 Wilson Boulevard Arlington, Virginia 22201-3834 or call (703) 90
10、7-7559 JEDEC Publication No. 140 -i- GUIDELINE FOR BEADED THERMOCOUPLE TEMPERATURE MEASUREMENT OF SEMICONDUCTOR PACKAGES Foreword This guideline provides procedures to accurately and consistently measure the temperature of components during exposure to thermal excursions. The guideline applications
11、can include, but is not limited to, temperature profile measurement in reliability test chambers and solder reflow operations that are associated with component assembly to printed wiring boards (pwb). JEDEC Publication No. 140 -ii- JEDEC Publication No. 140 Page 1 GUIDELINE FOR BEADED THERMOCOUPLE
12、TEMPERATURE MEASUREMENT OF SEMICONDUCTOR PACKAGES (From JEDEC Board Ballot JCB-02-34, formulated under the cognizance of the JC-14.1 Subcommittee on Reliability Test methods for Packaged Devices.) 1 Scope This method specifies procedures to determine the temperature of a component or its solder join
13、t over time as it is exposed to temperature gradients due to testing or processing. It defines appropriate thermometry sensors, tools, and attachment methods for temperature measurement of semiconductor packages in the applications mentioned in the Foreword 2 Applicable Documents ASTM STP 852, Manua
14、l on the Use of Thermocouples ASTM Manual 12, On the Use of Thermocouples ASTM E220, Calibration of Thermocouples by Comparison Techniques IPC TM-650 2.6.20.3, Surface Thermometry of Plastic Parts with Low Thermal Mass, January 1999 3 Terms and definitions For the purposes of this procedure, the fol
15、lowing terms and definitions apply. 3.1 Thermometry sensors Devices and/ or materials used in the science of measuring the temperature of a system or the ability of systems to transfer heat. 3.2 Thermocouple A temperature measurement sensor that consists of two dissimilar metals intimately joined to
16、gether in a bead at one end (a junction) that produces a small thermoelectric voltage, corresponding to a temperature, when the junction is heated. JEDEC Publication No. 140 Page 2 3 Terms and definitions (contd) 3.3 Temperature profile A relational dependency of temperature as a function of time. 3
17、.4 Components Packaged semiconductor devices. 3.5 Emissivity The ratio of the radiant energy emitted by a surface to that emitted by a blackbody at the same temperature. 4 Apparatus The temperature profiling apparatus used shall be capable of providing accurate temperature profiles, nominally within
18、 1.5 C - 2.0 C of the actual temperature of the components in the working zone(s) in the heated and cooled equipment; such as, reliability test chambers or solder reflow ovens. Periodic calibration of thermometric measurement technique chosen should be incorporated into the process using reference c
19、riteria as required to ensure run-to-run repeatability. 5 Procedure A number of procedures for temperature profiling exist. The method selected depends on the types of results required, the accuracy needed and the physical layout of the equipment/ componentry being profiled. Based on the type of equ
20、ipment referenced in this guideline, use of beaded thermocouples to measure the temperature profiles is the most effective and useful. Other methods, such as fluoroptic thermometry, IR thermometric probes, phase change materials, ribbon thermocouples, etc., are not well suited to these applications
21、due to either line of sight, continuous monitoring or temperature accuracy requirements. JEDEC Publication No. 140 Page 3 5 Procedure (contd) 5.1 Thermocouple (T/C) used to measure component temperature The thermocouple is the most common thermometric tool in surface mount reflow and component therm
22、ometry. Thermocouples are relatively inexpensive, have fast response times and are well supported by an electronic instrumentation and computing infrastructure. Data logging equipment supporting four and more channels is available. The thermocouples thermal effects on the apparent temperature of the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JEDECJEP1402002BEADEDTHERMOCOUPLETEMPERATUREMEASUREMENTOFSEMICONDUCTORPACKAGES 半导体 温度 测试 PDF

链接地址:http://www.mydoc123.com/p-806971.html