ISA TR75 25 02-2000 Control Valve Response Measurement from Step Inputs《控制阀分布输入反应测量》.pdf
《ISA TR75 25 02-2000 Control Valve Response Measurement from Step Inputs《控制阀分布输入反应测量》.pdf》由会员分享,可在线阅读,更多相关《ISA TR75 25 02-2000 Control Valve Response Measurement from Step Inputs《控制阀分布输入反应测量》.pdf(44页珍藏版)》请在麦多课文档分享上搜索。
1、 ANSI Technical Report prepared by ISA ANSI/ISA-TR75.25.02-2000 (R2010) Control Valve Response Measurement from Step Inputs Approved 18 July 2010 ANSI/ISA-TR75.25.02-2000 (R2010) Control Valves Response Measurement from Step Inputs ISBN: 978-1-936007-50-9 Copyright 2010 by ISA. All rights reserved.
2、Not for resale. Printed in the United States of America. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), without the prior written permission of the Publisher. IS
3、A 67 Alexander Drive P. O. Box 12277 Research Triangle Park, North Carolina 27709 - 3 - ANSI/ISA-TR75.25.02-2000 (R2010) Preface This preface, as well as all footnotes and annexes, is included for information purposes and is not part of ANSI/ISA-TR75.25.022000 (R2010). The standards referenced withi
4、n this document may contain provisions which, through reference in this text, constitute requirements of this document. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this document are encouraged to investigate
5、 the possibility of applying the most recent editions of the standards indicated within this document. Members of IEC and ISO maintain registers of currently valid International Standards. ANSI maintains registers of currently valid U.S. National Standards. This document has been prepared as part of
6、 the service of ISA toward a goal of uniformity in the field of instrumentation. To be of real value, this document should not be static but should be subject to periodic review. Toward this end, the Society welcomes all comments and criticisms and asks that they be addressed to the Secretary, Stand
7、ards and Practices Board; ISA; 67 Alexander Drive; P. O. Box 12277; Research Triangle Park, NC 27709; Telephone (919) 549-8411; Fax (919) 549-8288; E-mail: standardsisa.org. The ISA Standards and Practices Department is aware of the growing need for attention to the metric system of units in general
8、, and the International System of Units (SI) in particular, in the preparation of instrumentation standards. The Department is further aware of the benefits to USA users of ISA standards of incorporating suitable references to the SI (and the metric system) in their business and professional dealing
9、s with other countries. Toward this end, this Department will endeavor to introduce SI-acceptable metric units in all new and revised standards, recommended practices, and technical reports to the greatest extent possible. Standard for Use of the International System of Units (SI): The Modern Metric
10、 System, published by the American Society for Testing ISA; 67 Alexander Drive; P. O. Box 12277; Research Triangle Park, NC 27709. This technical report applies to throttling control valves in closed loop control applications. The concept has some application to open loop control applications but do
11、es not address control valves used in on-off control service. In the context of this document, the control valve includes these components a valve, an actuator, a motion conversion mechanism, and accessories such as a positioner, transducer, signal booster relay, air set, snubber, etc. Abstract This
12、 technical report describes the characteristic response of a control valve to step input signal changes, considering the factors that affect this response, the impact of the response on the quality of process control, and the appropriate control valve specifications. In this document, a control valv
13、e is the complete control valve body, with actuator and any accessories required for normal operation assembled and ready for use. This document identifies and defines four regions of control valve response to step input changes of varying sizes and provides guidance that can be used to relate the c
14、ontrol valve performance to process control. Key Words Accessories, actuator, amplitude, backlash, bench test, closed loop, closed loop time constant, control valve, dead band, dead time, dynamic response, flow coefficient, hunting, in-process test, laboratory test, limit cycle, motion conversion me
15、chanism, nonlinear, open loop, overshoot, process control, process response, resolution, response, static, steady state, stem position, step change, step input signal changes, step response time, step size, step test, throttling control valve, time constant, valve, velocity limiting. This page inten
16、tionally left blank. - 13 - ANSI/ISA-TR75.25.02-2000 (R2010) 1 Purpose This technical report describes the characteristic response of a control valve to step input signal changes. It considers the factors that affect this response, the impact of the response on the quality of process control, and th
17、e appropriate control valve specifications. In this document, a control valve is the complete control valve body, with actuator and any accessories required for normal operation assembled and ready for use. This document supports standard ANSI/ISA-75.25.01-2000 (R2010), “Test Procedure for Control V
18、alve Response Measurement from Step Inputs.“ See the standard for the test procedures. Users and manufacturers have developed a better understanding of the effects of control valve response characteristics on process control. This document identifies and defines four regions of control valve respons
19、e to step input changes of varying sizes. Existing standards do not include the definitions and methods to measure certain valve characteristics now understood to be important. This technical report provides guidance that can be used to relate the control valve performance to process control. 2 Scop
20、e This technical report applies to throttling control valves in closed loop control applications. The concept has some application to open loop control applications. It does not address control valves used in on-off control service. The “control valve” in the context of this document includes the fo
21、llowing components: Valve: A valve is a device used for the control of fluid flow. It consists of a fluid containing valve body assembly, one or more ports between connection openings and a moveable closure member, which opens, restricts or closes the port(s) (see ANSI/ISA-75.05.01-2000 (R2005), “Co
22、ntrol Valve Terminology“). Actuator: An actuator is a device that supplies the force and causes the movement of the valve closure member. Commonly these are fluid or electrically powered (see ANSI/ISA-75.05.01-2000 (R2005). Actuators often use air but other types use electric, hydraulic and electro-
23、hydraulic power. Motion conversion mechanism: A mechanism installed between the valve and the power unit of the actuator to convert between linear and rotary motion where required. The conversion may be from linear actuator action to rotary valve operation or from rotary actuator action to linear va
24、lve operation. Accessories: Additional devices used in the operation of the control valve. As described in ANSI/ISA-75.05.01-2000 (R2005), typical examples include a positioner, transducer, signal booster relay, air set, snubber, etc. 3 Definitions This document and ANSI/ISA-75.25.01-2000 (R2010) ma
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISATR7525022000CONTROLVALVERESPONSEMEASUREMENTFROMSTEPINPUTS 控制 分布 输入 反应 测量 PDF

链接地址:http://www.mydoc123.com/p-789979.html