ISA 37 6-1982 Specifications and Tests for Potentiometric Pressure Transducers《电位式压力传感器的规范和试验 原标准号ISA-S37 6-1982 (R1995)》.pdf
《ISA 37 6-1982 Specifications and Tests for Potentiometric Pressure Transducers《电位式压力传感器的规范和试验 原标准号ISA-S37 6-1982 (R1995)》.pdf》由会员分享,可在线阅读,更多相关《ISA 37 6-1982 Specifications and Tests for Potentiometric Pressure Transducers《电位式压力传感器的规范和试验 原标准号ISA-S37 6-1982 (R1995)》.pdf(42页珍藏版)》请在麦多课文档分享上搜索。
1、Specifications and Tests for Potentiometric PressureTransducersReaffirmed 29 September 1995ISA37.61982 (R1995)Formerly ISAS37.61982 (R1995)STANDARDISA The Instrumentation,Systems, andAutomation Society TMCopyright 1982 by the Instrument Society of America. All rights reserved. Printed in the UnitedS
2、tates of America. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form or by any means (electronic, mechanical, photocopying, recording, orotherwise), without the prior written permission of the publisher.ISA67 Alexander DriveP.O. Box 12277Research T
3、riangle Park, North Carolina 27709ISA-37.6-1982 (R1995), Specifications and Tests for Potentiometric Pressure TransducersISBN 0-87664-380-2ISA-S37.6-1982 (R1995) 3PrefaceThis preface, as well as all footnotes and annexes, is included for information purposes and is not part of ISA-37.6-1982 (R1995).
4、This standard has been prepared as a part of the service of ISA, the international society for measurement and control, toward the goal of uniformity in the field of instrumentation. To be of real value, this document should not be static, but should be subject to periodic review. Toward this end, t
5、he Society welcomes all comments and criticisms and asks that they be addressed to the Secretary, Standards and Practices Board; ISA; 67 Alexander Drive; P.O. Box 12277; Research Triangle Park, NC 27709; Telephone: (919) 549-8411; Fax: (919) 549-8288; E-mail: standardsisa.org.The ISA Standards and P
6、ractices Department is aware of the growing need for attention to the metric system of units in general, and the International System of Units (SI) in particular, in the preparation of instrumentation standards, recommended practices, and technical reports. The Department is further aware of the ben
7、efits to USA users of ISA Standards of incorporating suitable references to the SI (and the metric system) in their business and professional dealings with other countries. Toward this end, this Department will endeavor to introduce SI-acceptable metric units in all new and revised standards to the
8、greatest extent possible. The Metric Practice Guide, which has been published by the Institute of Electrical and Electronics Engineers as ANSI/IEEE Std. 268-1992, and future revisions, will be the reference guide for definitions, symbols, abbreviations, and conversion factors.It is the policy of ISA
9、 to encourage and welcome the participation of all concerned individuals and interests in the development of ISA standards, recommended practices, and technical reports. Participation in the ISA standards-making process by an individual in no way constitutes endorsement by the employer of that indiv
10、idual, of ISA, or of any of the standards which ISA develops.This Standard is intended as a guide for technical personnel at user facilities as well as by manufacturers technical and sales personnel whose duties include specifying, calibrating, testing or showing performance characteristics of poten
11、tiometric pressure transducers. By basing users specifications as well as technical advertising and reference literature on this Standard, or by referencing portions thereof, as applicable, a clear understanding of the users needs or of the transducers performance capabilities, and of the methods us
12、ed for evaluating or proving performance, will be provided. Adhering to the specification outline, terminology and procedures shown will not only result in simple, but also complete specifications; it will also reduce design time, procurement lead time, and labor, as well as material costs. Of major
13、 importance will be the reduction of qualification tests resulting from use of a commonly accepted test procedure and uniform data presentation.The development of this Standard was initiated as the result of a survey conducted in December, 1960. A total of 240 questionnaires was sent out to transduc
14、er users and manufacturers. A strong majority indicated in their replies a need for transducer standardization. As potentiometric pressure transducers were one of the types shown to be most in need of standardization, a project subcommittee, SP37.6, Potentiometric Pressure Transducers, was formed un
15、der the cognizance of Committee SP37, Transducers for Aerospace Testing, and a standard was developed and published in 1967. Subsequently, the standard was reviewed extensively, and revised in 1974. The reviewers were selected from a broad cross-section of all industries and sciences in which transd
16、ucers are applied for measuring purposes.4 ISA-S37.6-1982 (R1995)The following individuals served on the 1969 SP37 committee:NAME COMPANYP. S. Lederer, Chairman National Bureau of StandardsJ. F. Mayo-Wells National Bureau of StandardsR. R. Bouche ENDEVCOH. C. Chandon Rosemount, Inc.J. Hilten Nationa
17、l Bureau of StandardsH. N. Norton Jet Propulsion LaboratoryJ. J. Elengo Revere Corporation of AmericaO. C. Ingebritsen NASA/Langley Research CenterR. D. Bronson Lockheed Electronics CompanyJ. Z. Inskeep Jet Propulsion LaboratoryThe following individuals served on the ISA Committee SP37, who reaffirm
18、ed ISA-S37.5 in 1995:NAME COMPANYE. Icayan, Chairman Westinghouse Hanford Co.J. Weiss Electric Power Research Inst.P. Bliss, Deceased ConsultantM. Brigham The Supply SystemD. Hayes LA Dept. Water e.g., psia for absolute pressure in psi. In the interim it is recommended that for the SI system, the ty
19、pe of pressure be indicated in this manner: “. . . An absolute pressure of _Pa.“ “. . . A differential pressure range of _ kPa,“ etc.2. For differential pressure transducers, the allowable range of reference pressures shall be listed; e.g., “0 to 1MPa“ or “0 to 100 psi.“4.1.1.2 Measured fluids*The f
20、luids in contact with pressure port(s) shall be listed; e.g., nitric acid, liquid oxygen. Requirements for and limitations on the isolating element (if used) shall be listed.4.1.1.3 Configuration and dimensionsThe outline drawing shall show the configuration with dimensions in millimeters (inches).
21、Unless pressure and electrical connections are specified (reference 4.1.1.5 and 4.1.3.4), the outline shall include limiting maximum dimensions for these connections.4.1.1.4 Mountings and mounting dimensionsUnless the pressure connection serves as a mounting, the outline drawing shall indicate the m
22、ethod of mounting with hole size, centers, and other pertinent dimensions in millimeters (inches), including thread specifications for threaded holes, if used.4.1.1.5 Pressure connectionThe pressure connection(s) shall be indicated on the outline drawing. For threaded fittings, specify Applicable Mi
23、litary or Industry standards or nominal size, number of threads per millimeter (threads per inch), thread series, and thread class. For hose tube fitting, specify tube size.4.1.1.6 Mounting effectsThe maximum mounting force or torque shall be specified if it will tend to affect transducer performanc
24、e (reference 4.2.28).4.1.1.7 MassThe mass of the transducer shall be specified to grams (ounces).4.1.1.8 Case sealingIf case sealing is necessary, the mechanism and materials used for sealing should be described. The same requirement applies to the electrical connector. The resistance of the sealing
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISA3761982SPECIFICATIONSANDTESTSFORPOTENTIOMETRICPRESSURETRANSDUCERS 电位 压力传感器 规范 试验 标准 ISAS3761982R1995PDF

链接地址:http://www.mydoc123.com/p-789701.html