ISA 37 5-1982 Specifications and Tests for Strain Gage Linear Accelerator Transducers《应变计式线性加速传感器的规范和试验 原标准号ISA-S37 5-1982 (R1995)》.pdf
《ISA 37 5-1982 Specifications and Tests for Strain Gage Linear Accelerator Transducers《应变计式线性加速传感器的规范和试验 原标准号ISA-S37 5-1982 (R1995)》.pdf》由会员分享,可在线阅读,更多相关《ISA 37 5-1982 Specifications and Tests for Strain Gage Linear Accelerator Transducers《应变计式线性加速传感器的规范和试验 原标准号ISA-S37 5-1982 (R1995)》.pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、Specifications and Tests for Strain Gage LinearAccelerator TransducersReaffirmed 29 September 1995ISA37.51982 (R1995)Formerly ISAS37.51982 (R1995)STANDARDISA The Instrumentation,Systems, andAutomation Society TMCopyright 1982 by the Instrument Society of America. All rights reserved. Printed in the
2、UnitedStates of America. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form or by any means (electronic, mechanical, photocopying, recording, orotherwise), without the prior written permission of the publisher.ISA67 Alexander DriveP.O. Box 12277Res
3、earch Triangle Park, North Carolina 27709ISA-37.5-1982 (R1995), Specifications and Tests for Strain Gage Linear Acceleration TransducersISBN 0-87664-379-9ISA-S37.5-1982 (R1995) 3PrefaceThis preface, as well as all footnotes and annexes, is included for informational purposes and is not part of ISA-3
4、7.5-1982 (R1995).This standard has been prepared as a part of the service of ISA, the international society for measurement and control, toward a goal of uniformity in the field of instrumentation. To be of real value, this document should not be static, but should be subject to periodic review. Tow
5、ard this end, the Society welcomes all comments and criticisms, and asks that they be addressed to the Secretary, Standards and Practices Board; ISA; 67 Alexander Drive; P.O. Box 12277; Research Triangle Park, NC 27709; Telephone: (919) 549-8411; Fax: (919) 549-8288; E-mail: standardsisa.org.The ISA
6、 Standards and Practices Department is aware of the growing need for attention to the metric system of units in general, and the International System of Units (SI) in particular, in the preparation of instrumentation standards, recommended practices, and technical reports. The Department is further
7、aware of the benefits to USA users of ISA Standards of incorporating suitable references to the SI (and the metric system) in their business and professional dealings with other countries. Towards this end, this Department will endeavor to introduce SI-acceptable metric units in all new and revised
8、standards to the greatest extent possible. The Metric Practice Guide, which has been published by the Institute of Electrical and Electronics Engineers as ANSI/IEEE Std. 268-1992, and future revisions, will be the reference guide for definitions, symbols, abbreviations, and conversion factors.It is
9、the policy of ISA to encourage and welcome the participation of all concerned individuals and interests in the development of ISA standards, recommended practices, and technical reports. Participation in the ISA standards-making process by an individual in no way constitutes endorsement by the emplo
10、yer of that individual, of ISA, or of any of the standards, recommended practices, and technical reports that ISA develops.This standard is intended as a guide for technical personnel at user facilities as well as by manufacturers technical and sales personnel whose duties include specifying, calibr
11、ating, testing or showing performance characteristics of strain-gage linear accelerometers. By basing users specifications as well as technical advertising and reference literature on this standard, or by referencing portions thereof, as applicable, a clear understanding of the users needs or of the
12、 transducers performance capabilities, and of the methods used for evaluating or proving performance, will be provided. Adhering to the specification outline, terminology and procedures shown will not only result in simple, but also complete specifications; it will also reduce design time, procureme
13、nt lead time, and labor, as well as material costs. Of major importance will be the reduction of qualification tests resulting from use of a commonly accepted test procedure and uniform data presentation.The development of this Standard was initiated as the result of a survey conducted in December 1
14、960. A total of 240 questionnaires was sent out to transducer users and manufacturers. A strong majority indicated in their replies a need for transducer standardization. As strain-gage acceleration transducers were one of the types shown to be most in need of standardization, a Subcommittee, 8A-RP3
15、7.5, was formed under the former Survey Committee on Transducers for Aerospace Testing, 8A-RP37. Subcommittee 8A-RP37.5 became Standards Committee SP37.5 when the scope of the committees work was broadened to include the applications of these transducer types by all industries and sciences. To provi
16、de a coordinated document, this committee was composed of representatives from government, user, and manufacturer 4 ISA-S37.5-1982 (R1995)categories. This Standard was then processed over several mail-review and revision cycles until a consensus of reviewers was reached, and it was published as ISA
17、Standard in 1971. It was approved as ANSI Standard MC 6.3-1975 in October 1975.The assistance of those who aided in the preparation of this document by answering questionnaires, offering suggestions, and in other ways, is gratefully acknowledged.The following individuals served as members of the 197
18、5 SP37.5 committee:NAME COMPANYL. L. Lathrop, Chairman (1965-71) Sandia LaboratoriesR. M. Canzoneri, Secretary Bell and HowellG. D. Goodrich Statham Instruments, Inc.J. S. Hilten, Chairman (1971-) National Bureau of StandardsG. C. MachenDeceased U.S. Naval Missile CenterE. D. Pettler ConsultantD. Sh
19、annon, Alternate Bell and HowellThe following individuals served on the ISA Committee SP37, who reaffirmed ISA-S37.5 in 1995:NAME COMPANYE. Icayan, Chairman Westinghouse Hanford Co.J. Weiss Electric Power Research Inst.P. Bliss ConsultantM. Brigham Washington Public Power Supply SystemD. Hayes LA De
20、pt. of Water a double asterisk appears after those terms defined in this Standard.2 PurposeThis Standard establishes the following for strain-gage linear acceleration transducers:a) Uniform minimum specifications for design and performance characteristicsb) Uniform acceptance and qualification test
21、methods, including calibration techniquesc) Uniform presentation of minimum test datad) A drawing symbol for use in electrical schematics (see Note in Section 3)3 Uniform drawings and symbols3.1 Drawing symbolThe electrical diagram symbol for a linear strain-gage acceleration transducer is a square
22、of dimensions 2x by 2x, with an added equilateral triangle, the base of which is the left side of the square. The triangle symbolizes the sensing element. The letter “a“ in the triangle designates linear (rectilinear) acceleration.NOTE Angular acceleration is designed by the Greek letter alpha ().Th
23、e strain gage bridge is symbolized by a small square, with diagonals x by x, centered in the large square. The diagonals of the small square are drawn perpendicular to the sides of the large square. Lines from each apex of the small square projected to the right side of the large square represent th
24、e electrical leads.10 ISA-S37.5-1982 (R1995)NOTE This symbol is not ANSI approved at this time. It has been submitted to the ANSI Y32 Committee on Graphic Symbols for their consideration and approval.3.2 Outline drawingsOrthogrographic projection outline drawings, with tolerances should include the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISA3751982SPECIFICATIONSANDTESTSFORSTRAINGAGELINEARACCELERATORTRANSDUCERS 应变 线性 加速 传感器 规范 试验 标准 ISAS3751982R1995PDF

链接地址:http://www.mydoc123.com/p-789700.html