《ISA 12 12 03-2011 Standard for Portable Electronic Products Suitable for Use in Class I and II Division 2 Class I Zone 2 and Class III Division 1 and 2 Hazardous (Classified) Locat.pdf》由会员分享,可在线阅读,更多相关《ISA 12 12 03-2011 Standard for Portable Electronic Products Suitable for Use in Class I and II Division 2 Class I Zone 2 and Class III Division 1 and 2 Hazardous (Classified) Locat.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、 AMERICAN NATIONAL STANDARD ANSI/ISA-12.12.03-2011 Standard for Portable Electronic Products Suitable for Use in Class I and II, Division 2, Class I Zone 2 and Class III, Division 1 and 2 Hazardous (Classified) Locations Approved 12 July 2011 ANSI/ISA-12.12.03-2011 Standard for Portable Electronic P
2、roducts Suitable for Use in Class I and II, Division 2, Class I Zone 2 and Class III, Division 1 and 2 Hazardous (Classified) Locations ISBN: 978-1-936007-97-4 Copyright 2011 by ISA, the International Society of Automation. All rights reserved. Not for resale. Printed in the United States of America
3、. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means (electronic mechanical, photocopying, recording, or otherwise), without the prior written permission of the Publisher. ISA 67 Alexander Drive P.O. Box 12277 Research Triangle Par
4、k, North Carolina 27709 USA - 3 - ANSI/ISA-12.12.03-2011 Preface This preface, as well as all footnotes and annexes, is included for information purposes and is not part of ANSI/ISA-12.12.03-2011. This document has been prepared as part of the service of ISA toward a goal of uniformity in the field
5、of instrumentation. To be of real value, this document should not be static but should be subject to periodic review. Toward this end, the Society welcomes all comments and criticisms and asks that they be addressed to the Secretary, Standards and Practices Board; ISA; 67 Alexander Drive; P. O. Box
6、12277; Research Triangle Park, NC 27709; Telephone (919) 549-8411; Fax (919) 549-8288; E-mail: standardsisa.org. The ISA Standards and Practices Department is aware of the growing need for attention to the metric system of units in general, and the International System of Units (SI) in particular, i
7、n the preparation of instrumentation standards. The Department is further aware of the benefits to USA users of ISA standards of incorporating suitable references to the SI (and the metric system) in their business and professional dealings with other countries. Toward this end, this Department will
8、 endeavor to introduce SI-acceptable metric units in all new and revised standards, recommended practices, and technical reports to the greatest extent possible. Standard for Use of the International System of Units (SI): The Modern Metric System, published by the American Society for Testing see No
9、te 2 of 4.2 III 1 or 2 21 or 22 a) PEP 1 b) PEP 2 c) Any product that is listed for use in the location or d) Any product when a suitable work permit is in effect; see Note 2 of 4.2 I 1 0 or 1 a) Any product that is listed for use in the location or b) Any product when a gas free work permit is in e
10、ffect II 1 21 a) Any product that is listed for use in the location or b) Any product when a suitable work permit is in effect; see Note 2 of 4.2 NOTE 1 In the United States, an OSHA interpretation of 29CFR1910.399 requires that a listed product be used if it is available. Examples of available list
11、ed products include pagers, flashlights, and some test instruments. - 13 - ANSI/ISA-12.12.03-2011 NOTE 2 The application of PEP 1 and PEP 2 products in a hazardous (classified) location assumes that personnel will take the product with them when they vacate the area. NOTE 3 Text referring to Class I
12、 Division 1 and Class II Division 1 although outside the scope is provided for information only. 6 Portable Electronic Products (PEPs) 6.1 General PEP shall meet the following criteria: a) No available listed apparatus suitable for the area classification and capable of performing the intended funct
13、ion b) Radio frequency energy transmission limited in accordance with 8.3 c) No provisions for forced ventilation d) No sparks visible in normal operation e) No excessive temperatures in normal operation f) No camera flash unless it can be disabled g) No motors unless it can be demonstrated the moto
14、r incorporates non-arcing technology h) No visible damage 6.2 PEP 1 Products meeting the general criteria in 6.1 and all of the following additional criteria may be designated as PEP 1: a) Powered by a maximum of two button cells b) Body-worn and in direct contact with the skin c) No electrical conn
15、ections accessible outside the product Examples are electronic wristwatches and hearing aids that are inserted into the ears. 6.3 PEP 2 Products meeting the general criteria in 6.1 and all of the following additional criteria may be designated as PEP 2: a) Powered by one or more cells, batteries, or
16、 photovoltaic cells b) Cell or battery secured so it will not fall out in the drop test as described of 8.1 c) Body-worn or hand-held d) No external electrical connections or wired accessories are used in the hazardous (classified) location. ANSI/ISA-12.12.03-2011 - 14 - NOTE Bluetooth headset is an
17、 example of a non-wired accessory. e) Exposed terminals (for example battery charging terminals) are either recessed or diode protected to prevent a discharge caused by an accidental shorting of these terminals. f) Power switch in accordance with 8.2 g) No damage that exposes the electrical/electron
18、ic circuitry as a result of the drop test described in 8.1 Examples are some calculators, some medical injection devices, electronic watches with calculators and some cell phones. 7 Administrative controls 7.1 General A process of administrative control and training is necessary to ensure that porta
19、ble products do not present an unacceptable risk of ignition when used in hazardous classified areas. 7.2 PEP 1 and PEP 2 The owner/operator of the hazardous (classified) location should establish a process of inspection in which a qualified person establishes that particular products can be accepte
20、d as PEP 1 or PEP 2. For PEP 1, products can be accepted without additional marking. For PEP 2, all accepted products should be marked in accordance with Clause 9. Supporting documentation for the PEP evaluations should be maintained for the life of the use of those products. This documentation shou
21、ld include information for the product such as reference number or code, product manufacturer and model, owner name, approver name, and date approved or equivalent information. NOTE The supporting documentation reference number or code may be a serial number, an approver generated tag number or othe
22、r means of unique identification to provide tracking with the documentation. 7.3 Safe/Hot Work Permit 7.3.1 Gas Free Work Permit A Gas Free Work Permit should incorporate the following: a) A measurement to confirm the absence of an ignitible concentration of any flammable gas or vapor b) Sampling to
23、 confirm the continued absence of a flammable gas or vapor c) Contingency plans for emergencies Annex A provides an example of a Gas Free Work Permit process that incorporates these requirements and restrictions. - 15 - ANSI/ISA-12.12.03-2011 7.3.2 Dust Free Work Permit A similar concept to the Gas
24、Free Work Permit may also be applied to areas with combustible dusts or ignitible fibers although measurement and sampling are not required. Visual analysis is usually sufficient. 8 Examination and testing 8.1 Drop test For PEP 2, the product shall be able to pass a drop test. The product (or a samp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISA1212032011STANDARDFORPORTABLEELECTRONICPRODUCTSSUITABLEFORUSEINCLASSIANDIIDIVISION2CLASSIZONE2ANDCLASSIIIDIVISION1AND2HAZARDOUSCLASSIFIEDLOCATPDF

链接地址:http://www.mydoc123.com/p-789687.html