FORD FLTM EU-BP 008-05-2001 ENGINE COOLANT IMMERSION TEST《发动机冷却液浸没试验》.pdf
《FORD FLTM EU-BP 008-05-2001 ENGINE COOLANT IMMERSION TEST《发动机冷却液浸没试验》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM EU-BP 008-05-2001 ENGINE COOLANT IMMERSION TEST《发动机冷却液浸没试验》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、FORD LABORATORY TEST METHOD EU-BP 008-05 Date 2001 0822 1994 02 28 ENGINE COOLANT IMMERSION TEST Action Revisions Revised Editorial - no technical change A. Cockman Application This test method is used to determine the effect of various water based fluids, such as ethylene glycol based engine coolan
2、ts, at elevated temperatures, on the mechanical properties of elastomeric compounds and automotive parts. Apparatus Required Erlenmeyer Extraction Flasks 100 mL, 500 mL, 250 mL - with tapered ground glass neck. Water Cooled Condenser Ground Glass Joint Adapters Hot Plate Boiling Chips or Glass Boili
3、ng Beads Specimen Hanger 1 mm dia stainless steel wire. Glass Beads 6 mm dia with 1 mm dia hole. To be used to separate specimens on wire hanger Graduates 1 x 500 mL; 1 x 10 mL Specimen Preparation A. Slab Stock. Thickness 2.00 mm +/- 0.1 mm per ASTM D 15 1. Prepare three tensile specimens from one
4、flat vulcanized sheet using Die C per ASTM D 412. Remove approx 3 mm from each end giving a total length of 100 mm. Punch 2 mm hole approx 5 mm from both ends to permit assembly on wire hanger. Copynght02001, Ford Global Technologies, Inc FORD LABORATORY TEST METHOD EU-BP 008-05 2. Prepare three vol
5、ume specimens from same sheet as in Step 1 above using a 25.4 x 50.8 mm die cutter per ASTM D 471. Punch 2 mm hole approx 5 mm from one end to permit assembly on wire hanger. 3. Volume of each tensile specimen is approx 2.82 cm3 and each volume specimen is approx 2.50 cm3. This total volume of three
6、 tensile plus three volume specimens is approx 16 cm3. B. Large Diameter Hoses such as Upper and Lower Radiator Hoses 1. Separate tube from remainder of hose. Lay flat and buff smooth to remove braid marks per ASTM D 15. 2. Prepare three tensile and three volume specimens from same section of hose a
7、s in Section A above. C. Small Diameter Hoses such as Heater Hoses 1. Separate tube per Section B-I above. 2. Prepare three tensile and three volume specimens from consecutive lengths of hose as in Section A. D. Automotive Parts such as Water Pump Seal Boots 1. A minimum of three parts shall be sele
8、cted and sectioned if necessary to obtain a total volume of 16 +/- 1 cm3 (equivalent to the volume of three tensile and three volume specimens). If the volume of these parts are below 15 cm3, additional parts may be added or the volume of solution used may be reduced proportionately and tested in al
9、ternate containers as described in Procedure, Part B, below. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 OC and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the sam
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMEUBP008052001ENGINECOOLANTIMMERSIONTEST 发动机 冷却液 浸没 试验 PDF

链接地址:http://www.mydoc123.com/p-747836.html