FORD FLTM BI 103-2-2001 PREPARATION OF PANELS FOR PAINT TESTS.pdf
《FORD FLTM BI 103-2-2001 PREPARATION OF PANELS FOR PAINT TESTS.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BI 103-2-2001 PREPARATION OF PANELS FOR PAINT TESTS.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BI 103-02 Date Action Revisions 2001 03 13 Revised Editorial no technical change A. Cockman 1990 01 16 Printed copies are uncontrolled Page 1 of 8 Copyright 2001, Ford Global Technologies, Inc. PREPARATION OF PANELS FOR PAINT TEST Application This method describes the ap
2、proved methods of preparing paint panels for laboratory tests of the applied coatings. Apparatus Required Pressure Cup De Vilbiss Type KB*, or equivalent. Pressure Gun De Vilbiss Type JGA502 - 704 FX or 704FF*, or equivalent. Suction Feed Spray Guns and Cups May be used for routine laboratory tests
3、(except metallics) but, in case of dispute or where specified, a pressure cup shall be used. Suction Cup TGC-545 and Suction Gun JGA-502-30EX, or approved equivalent. *Source: Aerograph DeVilbiss Co. Ltd. The DeVilbiss Co. Ringwood Road 300 Phillips Ave. West Howe, Bournemouth, Hants P.O. Box 913 En
4、gland Toledo, OH 43692 Spray Booth With at least one meter minimum width for spraying panels automatically. The booth should be slightly pressurized so that dirt, dust, etc., will not enter. Air flow of 45 - 60 m/min. is required to pass over the spray rack. The air make-up shall be filtered by stan
5、dard equipment designed for that purpose. The booth shall be air conditioned so as to maintain a temperature of 24 +/- C and a relative humidity of 45 - 65 %. A spray booth with at least a one meter minimum width is also required for proper hand spraying of panels. The spray booth shall be located i
6、n a room of sufficient size as to allow the operator to be unhampered in his movements while spraying the panels. The booth should be slightly pressurized so that dirt, dust, etc., will not enter. Air make-up shouldbe filtered by standard equipment designed for that purpose. FORD LABORATORY TEST MET
7、HOD BI 103-02 Page 2 of 8 Copyright 2001, Ford Global Technologies, Inc. Automatic Spray Equipment Required for spraying exterior and interior metallic body enamels. The Spraymation automatic spray equipment is recommended, however, any approved automatic spray machine is acceptable if the results w
8、ill correlate with Model 310540 Spraymation. In case of dispute, Spraymation Model 310540, with a De Vilbiss No. AGB Series 541 Gun, Needle, and Tip-AV 15 E with No. 30 air cap shall be used. Source: Spraymation Inc. 25 Amity St. Little Falls, N.J. U.S.A. Paint Mixer Red Devil No. 30, or equivalent
9、Source: Elcometer Ltd. Edge Lane Droylsden, Manchester England Laboratory Forced Air Oven Capable of maintaining a constant temperature of 180 +/- 2 C. Thickness Gage - (Ref: FLTM BI 117-01) Permascope with a constant pressure probe, or equivalent. Sources: Fischer Instrumentation (GB) Ltd Fischer M
10、esstechnik Arnhem Industrial Estate 7034 Maichingen Arnhem Road Industriestrasse 21 Newbury, Berks England Germany Test Panels Steel body skin panels ground to surface finish of 1.4 +/- 0.3 micrometre. C.L.A., or as otherwise specified in the relevant specification. Optional Panel Sizes: 100 mm x 30
11、0 mm 150 mm x 300 mm 75 mm x 230 mm 100 mm x 200 mm FORD LABORATORY TEST METHOD BI 103-02 Page 3 of 8 Copyright 2001, Ford Global Technologies, Inc. For special tests the use of Ford Test Panels to the following may be specified: UMA18001 - Bare steel - 150 x 190 x 0.75 mm UMA18002 - Phosphated stee
12、l - 150 x 190 x 0.75 mm UMA18002 - Phosphated steel - 105 x 300 x 0.75 mm The number of panels prepared shall be determined by the applicable Engineering Materials Specification; however, no less than four of each color shall be prepared. Panels used for test in Group 1 shall be phosphate coated to
13、meet the requirements of WSK-M3P1-C. Clean untreated panels may be used for the tests in Group 2. These panels shall be dried at 140 C (metal temperature) for five minutes in a forced air oven prior to painting to remove absorbed moisture and allowed to return to 23 +/- 2 C prior to application of t
14、he paint film. Group 1 Salt Spray Test FLTM BI 103-01 Water Immersion Test FLTM BI 104-01 Conical Mandrel Test FLTM BI 105-01 Adhesion Test FLTM BI 106-01 Chip Resistance Test FLTM BI 107-01 Cold Checking Test FLTM BI 107-02 Impact Test FLTM BI 108-01 Florida Exposure Group 2 Contrast Ratio FLTM BI
15、101-02 Dry Hiding Power FLTM BI 101-03 Dry Hiding Power (Straight Line Chart) FLTM BI 158-01 Intercoat Adhesion FLTM BI 106-02 Color Matching FLTM BI 109-01 Measurement of Gloss FLTM BI 110-01 Tukon Hardness of Paint FLTM BI 112-02 Water and Soap Resistance FLTM BI 113-01 Acid Resistance FLTM BI 113
16、-02 Perspiration Staining Resistance FLTM BI 113-03 Bleeding of Paint FLTM BI 114-01 Repair Color Match FLTM BI 115-01 Repair Color Match with Catalyst FLTM BI 115-02 Sward Hardness FLTM BI 112-01 FORD LABORATORY TEST METHOD BI 103-02 Page 4 of 8 Copyright 2001, Ford Global Technologies, Inc. Prepar
17、ation of Panels for Test The following methods describe the proper application of various primers, primer surfacers and enamels. Mixing The can of test material must be mixed for 10 minutes. After mixing, the paint is stirred with a spatula, allowing the tip to contact the bottom of the can. Mixing
18、is adequate if no evidence of settling is indicated when the spatula is withdrawn and examined. Spraying Viscosity The paint must be reduced to the proper spraying viscosity with the appropriate thinner as designated by the applicable Engineering Materials Specification. Measurement of viscosity is
19、conducted in accordance with FLTM BI 111-01. Spraying Panels When using the suction gun to spray panels, the distance between panels and gun must be 150 - 200 mm with the following line pressures: All metallic colors 450 kN/m2 All solid colors 450 kN/m2 Air dry service enamels 410 kN/m2 The followin
20、g conditions have been found suitable when using a suction gun: 1. Paint volume flow 350 +/- 50 ml/minute (with xylol). 2. Fluid tip AV601EX. 3. Needle JGA 402 D-EX. 4. Air pressure equivalent to 410 kN/m2 When using a pressure gun the fluid flow should be 450 - 565 mL/minute whether the material is
21、 reduced for hot or cold spray. Cup or tank pressures should be sufficient to deliver the correct fluid flow. The distance from the panel to the spray gun should be 300 - 350 mm. When using the automatic spray gun, the line pressure should be 450 kN/m2 and the fluid flow 390 - 420 mL/minute with Xyl
22、ol. The traverse gun speed should be 34 traverses/minute with one minute flash time between coats. The distance from the gun tip to the panel should be 250 mm for metallics and 300 mm for solids and reflow metallics. FORD LABORATORY TEST METHOD BI 103-02 Page 5 of 8 Copyright 2001, Ford Global Techn
23、ologies, Inc. Electrocoat Application Electrocoating of panels shall be prepared in accordance with FLTM BI 120-01. Primer Application Primer is sprayed in two coats, each coat consisting of two passes with one (1) minute flash off time between coats. Water Sanding (Wet Sanding) Water sanding of pan
24、els is performed with No. 400 waterproof paper. The operation is performed in one direction only. After water sanding prime coated panels are rinsed with deionized or distilled water and wiped with chamois leather. Then each test panel will be wiped in sanding direction with a lint-free rag wetted w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBI10322001PREPARATIONOFPANELSFORPAINTTESTSPDF

链接地址:http://www.mydoc123.com/p-746957.html