EN 62116-2014 en Utility-interconnected photovoltaic inverters - Test procedure of islanding prevention measures.pdf
《EN 62116-2014 en Utility-interconnected photovoltaic inverters - Test procedure of islanding prevention measures.pdf》由会员分享,可在线阅读,更多相关《EN 62116-2014 en Utility-interconnected photovoltaic inverters - Test procedure of islanding prevention measures.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationUtility-interconnected photovoltaic inverters Test procedure of islanding prevention measuresBS EN 62116:2014National forewordThis British Standard is the UK implementation of EN 62116:2014. It is identical to IEC 62116:2014. It supersedes BS EN 62116:2011, which will bewith
2、drawn on 2 April 2017.The UK participation in its preparation was entrusted to TechnicalCommittee GEL/82, Photovoltaic Energy Systems.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provis
3、ions ofa contract. Users are responsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 78759 1ICS 27.160Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published unde
4、r the authority of theStandards Policy and Strategy Committee on 31 August 2014.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 62116:2014EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 62116 July 2014 ICS 27.160 Supersedes EN 62116:2011 English Version Uti
5、lity-interconnected photovoltaic inverters - Test procedure of islanding prevention measures (IEC 62116:2014) Onduleurs photovoltaques interconnects au rseau public - Procdure dessai des mesures de prvention contre llotage (CEI 62116:2014) Photovoltaik-Wechselrichter fr den Anschluss an das Stromver
6、sorgungsnetz - Prfverfahren fr Manahmen zur Verhinderung der Inselbildung (IEC 62116:2014) This European Standard was approved by CENELEC on 2014-04-02. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the
7、status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, Fr
8、ench, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austri
9、a, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
10、 Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CENELEC All rights of ex
11、ploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 62116:2014 E BS EN 62116:2014EN 62116:2014 - 2 - Foreword The text of document 82/813/FDIS, future edition 2 of IEC 62116, prepared by IEC/TC 82 “Solar photovoltaic energy systems“ was submitted to the IEC-CE
12、NELEC parallel vote and approved by CENELEC as EN 62116:2014. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-01-25 latest date by which the national standards confl
13、icting with the document have to be withdrawn (dow) 2017-04-02 This document supersedes EN 62116:2011. EN 62116:2014 includes the following significant technical changes with respect to EN 62116:2011: Previous edition Present edition 3.7 Real power Active power 5.1 5.4 6.1 b) 6.1 d) 6.1 e) 6.1 g) Ta
14、ble 1 Table 6 Table 7 Table 9 5.2 A PV array or PV array simulator (preferred) may be used. If the EUT can operate in utility-interconnected mode from a storage battery, a DC power source may be used in lieu of a battery as long as the DC power source is not the limiting device as far as the maximum
15、 EUT input current is concerned. A DC power source, such as a PV array simulator, a PV array, or a current and voltage limited DC power supply with series resistance may be used. If the EUT can operate in utility-interconnected mode from a storage battery, a DC power source may be used in lieu of a
16、battery as long as the DC power source shall not be the limiting device as far as the maximum EUT input current is concerned. BS EN 62116:2014- 3 - EN 62116:2014 Table 5 EUT input voltage 90 % EUT input voltage 75 % EUT input voltage 10 % EUT input voltage 20 % EUT Trip Settings Manufacturer specifi
17、ed voltage and frequency trip settings Voltage and frequency trip settings according to National standards and/or local code Tables 6 that procedure is the subject of this document. This standard provides a consensus test procedure to evaluate the efficacy of islanding prevention measures used by th
18、e power conditioner of utility-interconnected PV systems. Note that while this document specifically addresses inverters for photovoltaic systems, with some modifications the setup and procedure may also be used to evaluate inverters used with other generation sources or to evaluate separate anti-is
19、landing devices intended for use in conjunction with PV inverters or other generation sources acting as or supplementing the anti-islanding feature of those sources. Inverters and other devices meeting the requirements of this document can be considered non-islanding, meaning that under reasonable c
20、onditions, the device will detect island conditions and cease to energize the public electric power grid. BS EN 62116:2014IEC 62116:2014 IEC 2014 7 UTILITY-INTERCONNECTED PHOTOVOLTAIC INVERTERS TEST PROCEDURE OF ISLANDING PREVENTION MEASURES 1 Scope The purpose of this International Standard is to p
21、rovide a test procedure to evaluate the performance of islanding prevention measures used with utility-interconnected PV systems. This standard describes a guideline for testing the performance of automatic islanding prevention measures installed in or with single or multi-phase utility interactive
22、PV inverters connected to the utility grid. The test procedure and criteria described are minimum requirements that will allow repeatability. Additional requirements or more stringent criteria may be specified if demonstrable risk can be shown. Inverters and other devices meeting the requirements of
23、 this standard are considered non-islanding as defined in IEC 61727. This standard may be applied to other types of utility-interconnected systems (e.g. inverter-based microturbine and fuel cells, induction and synchronous machines). However, technical review may be necessary for other than inverter
24、-based PV systems. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN621162014ENUTILITYINTERCONNECTEDPHOTOVOLTAICINVERTERSTESTPROCEDUREOFISLANDINGPREVENTIONMEASURESPDF

链接地址:http://www.mydoc123.com/p-720977.html