EN 50131-4-2009 en Alarm systems - Intrusion and hold-up systems - Part 4 Warning devices《报警系统 侵入和拦劫系统 第4部分 报警装置[替代 CENELEC CLC TS 50131-4]》.pdf
《EN 50131-4-2009 en Alarm systems - Intrusion and hold-up systems - Part 4 Warning devices《报警系统 侵入和拦劫系统 第4部分 报警装置[替代 CENELEC CLC TS 50131-4]》.pdf》由会员分享,可在线阅读,更多相关《EN 50131-4-2009 en Alarm systems - Intrusion and hold-up systems - Part 4 Warning devices《报警系统 侵入和拦劫系统 第4部分 报警装置[替代 CENELEC CLC TS 50131-4]》.pdf(40页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationAlarm systems Intrusion andhold-up systems Part 4: Warning devicesBS EN 50131-4:2009National forewordThis British Standard is the UK implementation of EN 50131-4:2009. It super-s
2、edes DD CLC/TS 50131-4:2006 which is withdrawn.The UK participation in its preparation was entrusted by Technical CommitteeGW/1, Electronic security systems, to Subcommittee GW/1/1, Alarm compo-nents.A list of organizations represented on this committee can be obtained onrequest to its secretary.Thi
3、s publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2010ISBN 978 0 580 62769 9ICS 13.320Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under th
4、e authority of the StandardsPolicy and Strategy Committee on 31 March 2010Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 50131-4:2009EUROPEAN STANDARD EN 50131-4 NORME EUROPENNE EUROPISCHE NORM June 2009 CENELEC European Committee for Electrotechnical Standardiza
5、tion Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50131-4:2009 E ICS
6、 13.320 Supersedes CLC/TS 50131-4:2006English version Alarm systems - Intrusion and hold-up systems - Part 4: Warning devices Systmes dalarme - Systmes dalarme contre lintrusion et les hold-up - Partie 4: Dispositifs davertissement Alarmanlagen - Einbruch- und berfallmeldeanlagen - Teil 4: Signalgeb
7、er This European Standard was approved by CENELEC on 2009-05-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographic
8、al references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a C
9、ENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungar
10、y, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 50131-4:2009EN 50131-4:2009 - 2 - Foreword This European Standard was prepared by the Technical Committee
11、 CENELEC TC 79, Alarm systems. The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 50131-4 on 2009-05-01. This document supersedes CLC/TS 50131-4:2006. The following dates were fixed: latest date by which the EN has to be implemented at national l
12、evel by publication of an identical national standard or by endorsement (dop) 2010-05-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2012-05-01 EN 50131 will consist of the following parts, under the general title “Alarm systems Intrusion and hold-u
13、p systems“: Part 1 System requirements Part 2-2 Intrusion detectors - Passive infrared detectors Part 2-3 Requirements for microwave detectors Part 2-4 Requirements for combined passive infrared and microwave detectors Part 2-5 Requirements for combined passive infrared and ultrasonic detectors Part
14、 2-6 Opening contacts (magnetic) Part 2-7-1 Intrusion detectors - Glass break detectors (acoustic) Part 2-7-2 Intrusion detectors - Glass break detectors (passive) Part 2-7-3 Intrusion detectors - Glass break detectors (active) Part 3 Control and indicating equipment Part 4 Warning devices Part 5-3
15、Requirements for interconnections equipment using radio frequency techniques Part 6 Power supplies Part 7 Application guidelines Part 8 Security fog devices/systems BS EN 50131-4:2009- 3 - EN 50131-4:2009 Contents 1 Scope . 5 2 Normative references . 5 3 Definitions and abbreviations . 6 3.1 Definit
16、ions 6 3.2 Abbreviations . 7 4 General considerations 7 5 Requirements 7 5.1 Functional 7 5.2 Tamper . 9 5.3 Environmental 11 5.4 EMC .11 5.5 Safety .11 5.6 Electrical 12 5.7 Self test requirements 14 5.8 Marking 15 5.9 Documentation .15 6 Test section .15 6.1 Functional 16 6.2 Reduced functional te
17、st .16 6.3 Response to events .17 6.4 Acoustic .19 6.5 Tamper .19 6.6 Electrical tests 23 6.7 Marking 29 6.8 Documentation .30 6.9 Environmental 30 Annex A (normative) Sound level test for warning devices .33 Annex B (informative) Example remote test protocol .36 BS EN 50131-4:2009EN 50131-4:2009 -
18、4 - Figures Figure A.1 Suggested method of mounting 34 Figure A.2 Measurement positions Surface mounted devices 35 Figure A.3 Measurement positions Pole mounted devices . 35 Tables Table 1 Warning device functionality 7 Table 2 Warning device responses 8 Table 3 Acoustic output levels 9 Table 4 Encl
19、osure construction 10 Table 5 Tool dimension for tamper detection . 10 Table 6 Tamper detection. 11 Table 7 Removal from mounting 11 Table 8 Storage device standby duration . 13 Table 9 Recharge periods 13 Table 10 Self test monitoring 14 Table 11 Environmental tests selection 32 BS EN 50131-4:2009-
20、 5 - EN 50131-4:2009 1 Scope This European Standard includes requirements for warning devices used for notification in intrusion and hold up alarm systems installed in buildings. Four grades of warning device are described corresponding to each of the four security grades given in EN 50131-1. Requir
21、ements are also given for four environmental classes covering applications in internal and outdoor locations as specified in EN 50130-5. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited appl
22、ies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50130-4:1995, Alarm systems Part 4: Electromagnetic compatibility Product family standard: Immunity requirements for components of fire, intruder and social alarm systems A1:1998 A2:2003
23、 EN 50130-5:1998, Alarm systems Part 5: Environmental test methods EN 50131-1:2006, Alarm systems Intrusion and hold-up systems Part 1: System requirements EN 50131-6:2008, Alarm systems Intrusion and hold-up systems Part 6: Power supplies EN 60065:2002, Audio, video and similar electronic apparatus
24、 Safety requirements (IEC 60065:2001, mod.) EN 60068-1:1994, Environmental testing Part 1: General and guidance (IEC 60068-1:1988 + corrigendum October 1988 + A1:1992) EN 60068-2-75:1997, Environmental testing Part 2-75: Tests Test Eh: Hammer tests (IEC 60068-2-75:1997) EN 60529:1993 + corrigendum M
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN5013142009ENALARMSYSTEMSINTRUSIONANDHOLDUPSYSTEMSPART4WARNINGDEVICES 报警 系统 侵入 拦劫 部分 报警装置 替代 CENELECCLCTS501314

链接地址:http://www.mydoc123.com/p-716723.html